{"product_id":"cp703-yokogawa-field-control-station-processor-for-dcs","title":"CP703 Yokogawa | Field Control Station Processor for DCS","description":"\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CP703\u003c\/strong\u003e* functions as the primary high-performance processing engine for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS and CENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eField Control Stations (FCS). This advanced CPU module executes sophisticated control logic, orchestrates large-scale analog and digital I\/O communications, and maintains the integrity of the real-time process database. By doubling the memory capacity of its predecessor (CP701), the CP703 handles significantly more complex algorithms and larger tag counts, serving as the hardware foundation for demanding industrial automation environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCP703*\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eR4300 Microprocessor (Built-in Cache)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 MB DRAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Clock Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 MHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExternal Clock Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 MHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Bus\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVLnet, RS-232C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Management\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eH8S Microcontroller with Shared RAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports Dual-Redundant Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.3 V Low-Power Architecture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e700 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e100% Brand New Original\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Capacity Logic Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 MB DRAM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture allows engineers to implement extensive control schemes and larger functional block counts without compromising system scan rates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless VLnet Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CP703 facilitates high-speed data exchange between the FCS database and Human Interface Stations (HIS). This ensures that operators receive real-time process updates and alarm notifications with minimal latency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Power Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3.3 V low-power DRAM and flash memory\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesign, the module minimizes heat dissipation within the control cabinet, extending the lifespan of adjacent electronic components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault-Tolerant Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports full\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant configurations\u003c\/strong\u003e. In the event of a processor fault, the system triggers an instantaneous bumpless transfer to the standby CPU, preventing process interruptions in critical mission environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic I\/O Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn integrated H8S microcontroller manages dedicated I\/O access via shared RAM. This offloads routine communication tasks from the main R4300 processor, ensuring deterministic execution of time-critical control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the CP703 module replace a CP701 in an existing CENTUM system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Yes. The CP703 serves as an enhanced replacement for the CP701. It provides double the memory (16 MB vs. 8 MB) and faster processing speeds. However, you must verify that your current system software version supports the expanded memory map of the CP703.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does this unit ship with the necessary VLnet drivers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: The CP703 is a hardware module. The VLnet communication protocols are resident within the CENTUM CS\/VP system software. Once you seat the module in the FCS rack and perform the system generation (SYSGEN), the system initializes the communication drivers automatically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is this a refurbished or \"new-pull\" unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: No. We supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original Yokogawa\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eparts. Each CP703* unit arrives in its original factory packaging with a 12-month warranty, ensuring maximum reliability for your Distributed Control System.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How does the dual-redundancy work with the CP703?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: You install two CP703 modules in the designated processor slots of the FCS. The modules synchronize data in real-time across the backplane. If the primary CPU detects an internal hardware failure, the secondary CPU takes control of the I\/O bus within milliseconds to maintain continuous process control.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43753394438243,"sku":"CP703","price":240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/101_f3934a22-93ee-4667-bc22-3bf5cd428a99.jpg?v=1775784249","url":"https:\/\/www.autocontrolglobal.com\/bg\/products\/cp703-yokogawa-field-control-station-processor-for-dcs","provider":"AutoControl Global","version":"1.0","type":"link"}