{"product_id":"ge-fanuc-90-30-ic693mdl231-8-channel-240v-ac-input","title":"GE Fanuc 90-30 IC693MDL231 | 8-Channel 240V AC Input","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC693MDL231\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides high-voltage digital sensing for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSeries 90-30\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePLC platform. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal module features 8 isolated input points specifically designed to interface with 240V AC field devices. It converts high-voltage external signals from switches, pushbuttons, and limit sensors into logic-level data for the PLC processor. By utilizing individual isolation for each point, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693MDL231\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures maximum system reliability and prevents electrical faults in one circuit from affecting others within the same rack.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIC693MDL231\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIsolated AC Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e240 Volts AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 (Individually Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAC Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47 Hz to 63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 mA (Typical) at rated voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOn-state Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e156 to 265 Volts AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOff-state Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 40 Volts AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500V between field side and logic side\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 mA (Typical) from +5V bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +60 °C (32 to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePoint-to-Point Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard common-terminal modules, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693MDL231\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides complete electrical isolation between each of its 8 input channels. This allows engineers to mix different phases of AC power or separate power sources on a single module without risk of cross-talk or short circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Voltage Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module directly handles 240VAC inputs, eliminating the need for interposing relays or external voltage step-down transformers. This direct sensing streamlines cabinet wiring and reduces potential failure points in the control loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced System Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500V optical isolation protects the sensitive PLC backplane and CPU from high-voltage transients and surges common in heavy industrial power grids. This barrier prevents catastrophic hardware failure during field-side electrical faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstant Signal Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEight dedicated LED indicators on the front hinge-door provide real-time status of each input point. Maintenance personnel can verify the presence of 240V field power at a glance, significantly accelerating the troubleshooting of field-side switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Retrofit Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module fits any standard I\/O slot in a Series 90-30 rack. Its robust mechanical design allows it to replace aging or damaged units in legacy systems, ensuring continued operation of critical infrastructure without requiring software re-writes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use 120VAC signals with the IC693MDL231?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693MDL231\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequires a minimum \"On-state\" voltage of 156VAC. For 120VAC applications, you must use the IC693MDL230 module to ensure reliable signal detection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific terminal block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module comes with a standard removable terminal block. This allows you to replace the module without disconnecting the individual 240V field wires, minimizing downtime during maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle electrical noise?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module incorporates internal RC filtering to de-bounce input signals and reject high-frequency noise. This ensures the PLC logic only reacts to intentional state changes from the field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44075661131875,"sku":"IC693MDL231","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/410._dbd1647d-4890-4802-a646-e0df1dfb594f.jpg?v=1774338582","url":"https:\/\/www.autocontrolglobal.com\/bg\/products\/ge-fanuc-90-30-ic693mdl231-8-channel-240v-ac-input","provider":"AutoControl Global","version":"1.0","type":"link"}