{"title":"GE Fanuc PACSystems RX3i Controllers","description":"\u003cp\u003eThe GE Fanuc PACSystems RX3i Controllers are a series of high-performance, modular, and scalable control systems designed for complex industrial automation applications. Introduced by GE Fanuc Automation in April 2004, these controllers offer several key features:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Performance:\u003c\/strong\u003e The RX3i provides high-speed performance and efficient data handling capabilities, making it suitable for demanding industrial applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular and Scalable:\u003c\/strong\u003e Built on a modular architecture, users can customize the RX3i by adding or removing I\/O modules as needed, adapting it precisely to their application requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Programming Environment:\u003c\/strong\u003e The RX3i utilizes a unified control engine and programming environment, streamlining programming efforts and reducing development time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Availability:\u003c\/strong\u003e Configurable for high availability setups, the RX3i ensures continuous operation of critical processes by minimizing downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupports PACSystems Engine:\u003c\/strong\u003e These controllers support the PACSystems engine, offering a comprehensive suite of features tailored for process control, machine control, and motion control applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c!----\u003e","products":[{"product_id":"ge-fanuc-ic694apu300-high-speed-counter-module","title":"GE Fanuc IC694APU300 High Speed Counter Module","description":"\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC694APU300 is a high-speed counter module manufactured by GE Fanuc for use in the RX3i PACSystems series. It is designed to handle high-speed pulse signals, and it can be used for a variety of applications, such as flow rate measurement, speed control, and other dynamic industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-8 col-md-9\" id=\"featuresButton-3074457345626926263\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12\"\u003e\n\u003cul\u003e\n\u003cli\u003e12 positive logic (source) inputs with input voltage range selection of either 5 VDC or 10 to 30 VDC\u003c\/li\u003e\n\u003cli\u003e4 positive logic (source) outputs\u003c\/li\u003e\n\u003cli\u003eEnhanced version supports both Differential and Single-Ended Encoders. Classic version supports Single-Ended only\u003c\/li\u003e\n\u003cli\u003eCounts per timebase register for each counter\u003c\/li\u003e\n\u003cli\u003eInternal module diagnostics\u003c\/li\u003e\n\u003cli\u003eA removable terminal board for field wiring\u003c\/li\u003e\n\u003cli\u003eLEDs to indicate the state of each input, each output and three status LEDs (enhanced version only). Classic version has two LEDs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42151134199907,"sku":"IC694APU300","price":560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC694APU300_1.jpg?v=1741072950"},{"product_id":"ge-fanuc-ic694mdl660-digital-logic-24vdc-32pt-input-module","title":"GE Fanuc IC694MDL660 Digital Logic 24VDC 32pt Input Module","description":"\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003eIC694MDL660\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Count, Type \u0026amp; Speed:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e32 Point\u003c\/li\u003e\n\u003cli\u003ePositive\/Negative Logic\u003c\/li\u003e\n\u003cli\u003e0.5 to 100ms selectable On\/Off\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage and On\/Off Voltage:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e24VDC\u003c\/li\u003e\n\u003cli\u003eRange: 20-30V\u003c\/li\u003e\n\u003cli\u003eOn: \u0026gt;11.5V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current Consumption:\u003c\/strong\u003e300mA @ 5VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals \u0026amp; Standards for Ordinary Locations:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eEquivalent to CSA C22.2 No 142M1987 standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals \u0026amp; Standards for Hazardous Locations:\u003c\/strong\u003eClass I, Div. 2, Groups A, B, C, D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Format:\u003c\/strong\u003eOn Panel\/DIN Rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed and patented technology for faster throughput\u003c\/li\u003e\n\u003cli\u003eHot swap capability\u003c\/li\u003e\n\u003cli\u003eA variety of voltage ranges, types, current capacity, isolation, and response time to meet your application needs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42151137214563,"sku":"IC694MDL660","price":520.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC694MDL660_1.jpg?v=1741072949"},{"product_id":"ge-ic694pwr330-pacsystems-rx3i-power-supply-module","title":"GE IC694PWR330 PACSystems RX3i Power Supply Module","description":"\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe GE Fanuc RX3i IC694PWR330 power supply module is a high-capacity serial expansion power supply module that can run on AC and DC voltage. It needs to be installed in the serial expansion backplane of an RX3i PLC and it can operate with any RX3i CPU.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003eIC694PWR330\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003ePACSystems RX3i Serial Expansion Backplane (IC694 Series)\u003c\/li\u003e\n\u003cli\u003eOccupies 1 Slot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e120\/240 Vac or 125 Vdc Nominal\u003c\/li\u003e\n\u003cli\u003eRange: 85 to 264 Vac or 100 to 300 Vdc\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Capacity:\u003c\/strong\u003e30 W Total, All Loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation (Input to Backplane):\u003c\/strong\u003e1500 Vac for 1 minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e14 AWG to 22 AWG, 2 wires per terminal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indications:\u003c\/strong\u003ePower, OK, Run\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Sharing \u0026amp; Redundancy:\u003c\/strong\u003eNO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOperate: 0 to 60°C (32 to 140°F)\u003c\/li\u003e\n\u003cli\u003eStorage: -40 to +85°C (-40 to 185°F)\u003c\/li\u003e\n\u003cli\u003e5 to 95% humidity, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cem\u003eAgency Approvals:\u003c\/em\u003e\u003c\/strong\u003eUL, CE, ATEX, CCC, Marine (ABS, DNVGL)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cem\u003eOptions:\u003c\/em\u003e\u003c\/strong\u003eConformal Coated: IC694PWR330CA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42151359938659,"sku":"IC694PWR330","price":550.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC693PWR330_2_75183efd-465c-4598-9cce-cd950360776a.jpg?v=1741072948"},{"product_id":"ge-fanuc-ic695rmx128-rx3i-redundancy-memory-xchange-module","title":"GE Fanuc IC695RMX128 RX3i Redundancy Memory Xchange Module","description":"\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe GE IC695RMX128 is a Redundancy Memory Xchange (RMX) module designed for the GE Fanuc RX3i PACSystems series. It provides a high-speed, deterministic data exchange between CPUs and other devices on a reflective memory network or between CPUs in a hot standby CPU redundancy system. The IC695RMX128 features 128 megabytes of user-shared memory, making it ideal for applications that require high-speed data transfer.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e RX3i Redundancy Memory Xchange (RMX) Module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Fanuc Automation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eProduct Number:\u003c\/strong\u003e IC695RMX128\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eUser-Shared Memory:\u003c\/strong\u003e 128 megabytes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eLifecycle Status:\u003c\/strong\u003e Active\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e High-availability data synchronization link\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Support:\u003c\/strong\u003e Universal\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cp\u003eFeatures\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-8 col-md-9\" id=\"featuresButton-3074457345626926781\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12\"\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed and patented technology for faster throughput\u003c\/li\u003e\n\u003cli\u003eHot swap capability\u003c\/li\u003e\n\u003cli\u003eA variety of voltage ranges and current capacities to meet your application needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42151391297635,"sku":"IC695RMX128","price":560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC695RMX128_2.jpg?v=1741072947"},{"product_id":"ic695cpe330-ge-fanuc-rx3i-cpu-module","title":"IC695CPE330 | GE Fanuc | RX3i CPU Module","description":"\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003eIC695CPE330\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm Factor:\u003c\/strong\u003eBackplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser Memory:\u003c\/strong\u003e64MB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e32k Bits Discrete I\/O\u003c\/li\u003e\n\u003cli\u003e32k Words for Analog I\/O\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Pack:\u003c\/strong\u003eAvailable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMedia Redundancy (MRP)\u003c\/li\u003e\n\u003cli\u003ePROFINET System Redundancy (PNSR)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Port:\u003c\/strong\u003e3x 10\/100\/1000 (2 switched ports)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Protocols:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSRTP Client\/Server\u003c\/li\u003e\n\u003cli\u003eModbus TCP\/IP\u003c\/li\u003e\n\u003cli\u003eOPC UA (Non-Transparent Server Redundancy Server)\u003c\/li\u003e\n\u003cli\u003eEGD\u003c\/li\u003e\n\u003cli\u003ePROFINET\u003c\/li\u003e\n\u003cli\u003eDNP3 Outstation\u003c\/li\u003e\n\u003cli\u003eIEC-61850 Client\u003c\/li\u003e\n\u003cli\u003eIEC-104 Server\u003c\/li\u003e\n\u003cli\u003eHART passthrough\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Protocols:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eASCII Serial\u003c\/li\u003e\n\u003cli\u003eModbus\/RTU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote I\/O Devices:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e32 Simplex\u003c\/li\u003e\n\u003cli\u003e20 Redundant\u003c\/li\u003e\n\u003cli\u003e255 Simplex with PNC001\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB Interface:\u003c\/strong\u003e1x USB-A 2.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Card:\u003c\/strong\u003e1x CFast\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e0 to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approvals:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003ecUL\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFCC\u003c\/li\u003e\n\u003cli\u003eReach\u003c\/li\u003e\n\u003cli\u003eUL HazLoc C1D2\u003c\/li\u003e\n\u003cli\u003eATEX Zone 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Certifications:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eDNV GL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-8 col-md-9\" id=\"featuresButton-3074457345626927485\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12\"\u003e\n\u003cul\u003e\n\u003cli\u003eProgramming tools such as tag-based programming, a library of reusable code and a test edit mode for improved online troubleshooting\u003c\/li\u003e\n\u003cli\u003eUser-friendly environment that can increase design flexibility and improve engineering efficiency and productivity\u003c\/li\u003e\n\u003cli\u003ePlug-and-play addition of PROFINET-enabled devices makes it easy to securely connect machines, data and people\u003c\/li\u003e\n\u003cli\u003eHigh-speed multicore processor for faster throughput without information bottlenecks\u003c\/li\u003e\n\u003cli\u003eSupport for high-density discrete I\/O, universal analog (TC, RTD, Strain Gauge, Voltage and Current configurable per channel), isolated analog, high-density analog, high-speed counter, and motion modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42151428259939,"sku":"IC695CPE330","price":560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC695CPE330_2.jpg?v=1741072946"},{"product_id":"ge-fanuc-ic695alg600-pacsystems-rx3i-universal-analog-input-module","title":"GE Fanuc IC695ALG600 PACSystems RX3i Universal Analog Input Module","description":"\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct No.:\u003c\/strong\u003eIC695ALG600\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003eRX3i Universal Analog Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Power Requirements:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e300 mA maximum @ 5.0V\u003c\/li\u003e\n\u003cli\u003e320 mA maximum @ 3.3V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation within Module:\u003c\/strong\u003eThermal Dissipation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Resolution:\u003c\/strong\u003e11 to 16 bits, depending on configured range and A\/D filter frequency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Inputs:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e-10V to +10V\u003c\/li\u003e\n\u003cli\u003e0V to +10V\u003c\/li\u003e\n\u003cli\u003e0V to +5V\u003c\/li\u003e\n\u003cli\u003e1V to +5V\u003c\/li\u003e\n\u003cli\u003e-50mV to +50mV\u003c\/li\u003e\n\u003cli\u003e-150mV to +150mV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Inputs:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e-20mA to +20mA\u003c\/li\u003e\n\u003cli\u003e4 to 20mA\u003c\/li\u003e\n\u003cli\u003e0 to 20mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Input Filter:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e8 Hz\u003c\/li\u003e\n\u003cli\u003e12 Hz\u003c\/li\u003e\n\u003cli\u003e16 Hz\u003c\/li\u003e\n\u003cli\u003e40 Hz\u003c\/li\u003e\n\u003cli\u003e200 Hz\u003c\/li\u003e\n\u003cli\u003e1000 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScaling:\u003c\/strong\u003eFloating point user scaling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax RTD Cable Impedance:\u003c\/strong\u003e25 ohms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Wire Length:\u003c\/strong\u003e1000 ft max with a settling time of 1 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Input Resistance:\u003c\/strong\u003e249 ohms ± 1%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e0.18 Kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e1.5 Kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-8 col-md-9\" id=\"featuresButton-3074457345626926216\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12\"\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed and patented technology for faster throughput\u003c\/li\u003e\n\u003cli\u003eHot swap capability\u003c\/li\u003e\n\u003cli\u003eA variety of voltage ranges and current capacities to meet your application needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42151459094627,"sku":"IC695ALG600","price":570.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC695ALG600_1.jpg?v=1741072945"},{"product_id":"ge-fanuc-ic695etm001-rx3i-ethernet-module","title":"GE Fanuc IC695ETM001 RX3i Ethernet Module","description":"\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e IC695ETM001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecialty Module:\u003c\/strong\u003e RX3i Ethernet module\n\u003cul\u003e\n\u003cli\u003eSupports 10\/100 Mbits Ethernet\u003c\/li\u003e\n\u003cli\u003e2 RJ45 connections\u003c\/li\u003e\n\u003cli\u003eOccupies one slot on system base\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e840 mA @ 3.3 VDC\u003c\/li\u003e\n\u003cli\u003e614 mA @ 5 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Notes:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with Universal Backplane Only\u003c\/li\u003e\n\u003cli\u003eUses PCI Bus\u003c\/li\u003e\n\u003cli\u003eSupports Client\/Server configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed and patented technology for faster throughput\u003c\/li\u003e\n\u003cli\u003eHot swap capability\u003c\/li\u003e\n\u003cli\u003eOffers a variety of voltage ranges and current capacities to meet diverse application needs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42511674310755,"sku":"IC695ETM001","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC695ETM001_2.png?v=1741072338"},{"product_id":"ge-fanuc-ic698chs017-rx7i-17-slot-rear-mount-rack","title":"GE Fanuc IC698CHS017 Rx7i 17-Slot Rear Mount Rack","description":"\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003eDesigned for the Rx7i PACsystem series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003eOperating voltage ranges from 5 to 12 Volts DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003ePower supply capacity of 350 Watts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Current Rating:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e60 Amps at 5 Volts DC.\u003c\/li\u003e\n\u003cli\u003e4.0 Amps at 12 Volts DC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Capacity:\u003c\/strong\u003e17 slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFan Assembly:\u003c\/strong\u003eOptional fan assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003eApproximate dimensions: 11.2 x 19.0 x 7.5 inches (H x W x D).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type:\u003c\/strong\u003eRear mounting type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Inputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports 172 channels.\u003c\/li\u003e\n\u003cli\u003eAccepts 24 VDC or 24 VAC inputs.\u003c\/li\u003e\n\u003cli\u003eCurrent ratings: 20 mA or 10 mA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Outputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports 128 channels.\u003c\/li\u003e\n\u003cli\u003eOutputs 24 VDC or 24 VAC.\u003c\/li\u003e\n\u003cli\u003eCurrent ratings: 20 mA or 10 mA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Inputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports 32 channels.\u003c\/li\u003e\n\u003cli\u003eInput range: 0 to 10 VDC or 4 to 20 mA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42511873179747,"sku":"IC698CHS017","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC698CHS017_1.jpg?v=1741072333"},{"product_id":"ge-fanuc-ic698psa100-rx7i-power-supply-module","title":"GE Fanuc IC698PSA100 RX7i Power Supply Module","description":"\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDescription：\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe IC698PSA100 is a power supply module designed for the PACSystem RX7i platform.\u003c\/li\u003e\n\u003cli\u003eIt provides +5 VDC, +12 VDC, and -12 VDC power outputs, along with logic level sequencing signals to modules on the backplane.\u003c\/li\u003e\n\u003cli\u003eIt plugs directly into slot 0 in the main rack.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Range：\u003c\/strong\u003eOperates from 85 to 264 VAC or 100 to 150 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Rating：\u003c\/strong\u003eNominal input power: 125 Watts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e+5 VDC output: Up to 20 amps.\u003c\/li\u003e\n\u003cli\u003e+12 VDC output: Up to 2 amps.\u003c\/li\u003e\n\u003cli\u003e-12 VDC output: Up to 1 amp.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower supply output can withstand up to one AC input line cycle without losing output power.\u003c\/li\u003e\n\u003cli\u003eIncludes overcurrent, overtemperature, and overvoltage fault condition protection.\u003c\/li\u003e\n\u003cli\u003eProvides 100 watts total output power at ambient temperatures of 0 to 60ºC without forced air cooling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003eDesigned for simple slide-in rack mount construction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndicators:\u003c\/strong\u003eEquipped with LED indicators for field and output status monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42511909159011,"sku":"IC698PSA100","price":460.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC698PSA100_2.png?v=1741072332"},{"product_id":"ge-ic694mdl646-rx3i-dc-voltage-input-module","title":"GE IC694MDL646 RX3i DC Voltage Input Module","description":"\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e IC694MDL646\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Count, Type \u0026amp; Speed:\u003c\/strong\u003e 16 Points; Positive\/Negative Logic; 1ms On\/1ms Off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage and On\/Off Voltage:\u003c\/strong\u003e 24VDC; Range 20~30V; On \u0026gt;11.5V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current Consumption:\u003c\/strong\u003e 80mA @ 5VDC \u0026amp; 125mA @ 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals \u0026amp; Standards:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrdinary Locations:\u003c\/strong\u003e UL 508, equivalent to CSA C22.2 No 142M1987 standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Locations:\u003c\/strong\u003e Class I, Div. 2, Groups A, B, C, D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Format:\u003c\/strong\u003e On Panel\/DIN Rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed and patented technology for faster throughput\u003c\/li\u003e\n\u003cli\u003eHot swap capability\u003c\/li\u003e\n\u003cli\u003eA variety of voltage ranges, types, current capacities, isolation, and response times to meet diverse application needs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42594048475235,"sku":"IC694MDL646","price":480.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC694MDL660_1.jpg?v=1741072949"},{"product_id":"ge-ic694mdl742-rx3i-dc-voltage-output-module","title":"GE IC694MDL742 RX3i DC Voltage Output module","description":"\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e IC694MDL742\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Count, Type \u0026amp; Speed:\u003c\/strong\u003e UL, UL HAZLOC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Rating:\u003c\/strong\u003e Zone 2 CE, ATEX C1D2 ABS, BV, DNV, GL, KRS, LR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 34 x 145 x 140 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Galvanic Isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedia Connector:\u003c\/strong\u003e 2x RJ45 + 2x SFP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Format:\u003c\/strong\u003e On Panel\/DIN Rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-speed and Patented Technology:\u003c\/strong\u003e For faster throughput.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Swap Capability:\u003c\/strong\u003e Allows for replacement or addition of components without system shutdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Voltage Ranges and Types:\u003c\/strong\u003e To meet various application needs, including different current capacities, isolation requirements, and response times.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42594237907043,"sku":"IC694MDL742","price":420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC694MDL742_1.png?v=1741071797"},{"product_id":"ic694bem331-ge-fanuc-pacsystems-rx3i-genius-bus-controller","title":"IC694BEM331 | GE Fanuc | PACSystems RX3i Genius Bus Controller","description":"\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Number\u003c\/strong\u003e: IC694BEM331\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Genius Bus Controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInterfaces:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePACSystems RX3i\u003c\/li\u003e\n\u003cli\u003eGenius I\/O serial bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBus Capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInterfaces Genius blocks, other PLCs with Genius Bus Controllers, Remote Drops, VersaMax and Field Control I\/O Stations, Genius Hand-Held Monitor (HHM), and multiple hosts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced diagnostics capabilities for troubleshooting and system monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports Global Data and Datagrams.\u003c\/li\u003e\n\u003cli\u003eData Length: 128 bytes per message.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Rates:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfigurable:\n\u003cul\u003e\n\u003cli\u003e153.6Kbaud standard\/extended\u003c\/li\u003e\n\u003cli\u003e76.8Kbaud\u003c\/li\u003e\n\u003cli\u003e38.4Kbaud\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBus Type:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDaisy-chained bus cable (single twisted-pair plus shield or Twinax)\u003c\/li\u003e\n\u003cli\u003eFiber optical cable and modems can also be used.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBus Termination:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRequires 75, 100, 120, or 150 Ohm resistors at both ends of the electrical bus cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Bus Length:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e7800 feet at 38.4Kbaud\u003c\/li\u003e\n\u003cli\u003e4500 feet at 76.8Kbaud\u003c\/li\u003e\n\u003cli\u003e3500 feet at 153.6Kbaud extended\u003c\/li\u003e\n\u003cli\u003e2000 feet at 153.6Kbaud standard\u003c\/li\u003e\n\u003cli\u003eMaximum length also depends on cable type as specified in the Genius System and Communications Manual.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Number of Devices:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e32 devices at all baud rates except 38.4Kbaud.\u003c\/li\u003e\n\u003cli\u003e16 devices at 38.4Kbaud.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2000 volts Hi-Pot\u003c\/li\u003e\n\u003cli\u003e1500 volts transient common mode rejection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e0.37 kg (0.82 lbs)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e1.5 kg (3.3 lbs)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42594253013091,"sku":"IC694BEM331","price":420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC694BEM331.png?v=1741071796"},{"product_id":"ic695cru320-ge-fanuc-pacsystems-rx3i-redundancy-cpu","title":"IC695CRU320 | GE Fanuc | PACSystems RX3i Redundancy CPU","description":"\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003eGE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct No.:\u003c\/strong\u003eIC695CRU320\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003ePACSystems RX3i Redundancy CPU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCPU Performance\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFor performance data, refer to Appendix A of the PACSystems CPU Reference Manual, GFK-2222W or later.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBattery and Memory Retention\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFor battery selection, installation, and estimated life, refer to the PACSystems RX3i and RX7i Battery and Energy Pack Manual, GFK-2741.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProgram Storage\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRAM\u003c\/strong\u003e: Up to 64 MB of battery-backed RAM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlash Memory\u003c\/strong\u003e: 64 MB of non-volatile flash user memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePower Requirements\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e+3.3 Vdc\u003c\/strong\u003e: 1.0 Amps nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e+5 Vdc\u003c\/strong\u003e: 1.2 Amps nominal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOperating Temperature\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange\u003c\/strong\u003e: 0 to 60°C (32°F to 140°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloating Point\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime of Day Clock Accuracy\u003c\/strong\u003e: Maximum drift of 2 seconds per day\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElapsed Time Clock (Internal Timing) Accuracy\u003c\/strong\u003e: 0.01% maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmbedded Communications\u003c\/strong\u003e: RS-232, RS-485\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Protocols Supported\u003c\/strong\u003e: Modbus RTU Slave, SNP, Serial I\/O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane\u003c\/strong\u003e: Dual backplane bus support: RX3i PCI and high-speed serial bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCI Compatibility\u003c\/strong\u003e: Electrically compliant with PCI 2.2 standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProgram Blocks\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal\u003c\/strong\u003e: Up to 512 program blocks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Size per Block\u003c\/strong\u003e: 128 KB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMemory\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e%I and %Q\u003c\/strong\u003e: 32 Kbits for discrete I\/O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e%AI and %AQ\u003c\/strong\u003e: Configurable up to 32 Kwords\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e%W\u003c\/strong\u003e: Configurable up to the maximum available user RAM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSymbolic\u003c\/strong\u003e: Configurable up to 64 Mbytes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFlash Memory Endurance Rating\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum\u003c\/strong\u003e: 100,000 write\/erase cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMemory Error Checking and Correction (ECC)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Single bit correcting and multiple bit checking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSwitchover Time\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum\u003c\/strong\u003e: 1 logic scan\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum\u003c\/strong\u003e: 3.133 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMaximum Amount of Data in Transfer List\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to\u003c\/strong\u003e: 2 Mbytes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eNumber of Redundancy Links Supported\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to\u003c\/strong\u003e: Two IC695RMX128\/228 synchronization links\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eShipping Weight\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 2 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42630873350243,"sku":"IC695CRU320","price":560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC695CRU320_1.png?v=1741071560"},{"product_id":"ge-fanuc-ic695cpu315-rx3i-central-processing-unit","title":"GE Fanuc IC695CPU315 Rx3i Central Processing Unit","description":"\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct No.:\u003c\/strong\u003e IC695CPU315\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e RX3i Central Processing Unit (CPU)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifecycle Status:\u003c\/strong\u003e Active\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e Controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Support:\u003c\/strong\u003e Universal Backplane Only (Uses PCI Bus)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoolean Execution Speed:\u003c\/strong\u003e 0.047 ms\/K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser Logic Memory:\u003c\/strong\u003e 20 MB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Backed Real Time Clock:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Data Back-up:\u003c\/strong\u003e Battery Backup only\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Discrete Points:\u003c\/strong\u003e 32K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Analog Points:\u003c\/strong\u003e 32K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Memory Storage:\u003c\/strong\u003e SRAM, Flash\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor Speed:\u003c\/strong\u003e 1 GHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB -A 2.0 Master Port:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in Serial Ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOne RS-485 port\u003c\/li\u003e\n\u003cli\u003eOne RS-232 port\u003c\/li\u003e\n\u003cli\u003eSupports SNP, Serial I\/O, Modbus Slave, and Modbus Master (Application code)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Number of Local Racks:\u003c\/strong\u003e 8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommunications Options\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSerial\u003c\/li\u003e\n\u003cli\u003eGenius\u003c\/li\u003e\n\u003cli\u003eCMX (Reflective Memory)\u003c\/li\u003e\n\u003cli\u003eEthernet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eField Busses\/Device Networks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet (PROFINET, Ethernet Global Data, Channels, Modbus TCP Server and Client)\u003c\/li\u003e\n\u003cli\u003eGenius\u003c\/li\u003e\n\u003cli\u003ePROFIBUS DP\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware Programming Support\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProficy Machine Edition Logic Developer Professional edition 5.6 or above\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProgram Languages Supported\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFunction Block Diagram\u003c\/li\u003e\n\u003cli\u003eLadder Logic\u003c\/li\u003e\n\u003cli\u003eStructured Text\u003c\/li\u003e\n\u003cli\u003eC\u003c\/li\u003e\n\u003cli\u003eFunction Block Diagram\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Power Used\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1750 mA @ 3.3VDC\u003c\/li\u003e\n\u003cli\u003e1200 mA @ 5VDC (Check Data Sheet)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Slots Module Occupies on Backplane:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 3 kg\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42630882951267,"sku":"IC695CPU315","price":560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC695CPE330_1.jpg?v=1741072946"},{"product_id":"ge-fanuc-ic695cmu310-max-on-hot-standby-redundancy-cpu","title":"GE Fanuc IC695CMU310 Max-ON Hot-Standby Redundancy CPU","description":"\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC695CMU310 provides hot-standby CPU redundancy using two RX3i systems. The redundant controllers exchange operating data via one or two dedicated Ethernet LANs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgramming Languages Supported:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLadder Diagram\u003c\/li\u003e\n\u003cli\u003eStructured Text\u003c\/li\u003e\n\u003cli\u003eFunction Block Diagram\u003c\/li\u003e\n\u003cli\u003eC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e10 MB of battery-backed user memory\u003c\/li\u003e\n\u003cli\u003e10 MB of non-volatile flash user memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Ports:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTwo serial ports (RS-485 and RS-232)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax-ON redundancy applications include fuel loading, standby power generation, boiler systems, and manufacturing systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn-system upgradeable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1.0 A @ +5 VDC\u003c\/li\u003e\n\u003cli\u003e1.25 A @ +3.3 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Support:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUniversal Backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 pound\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42630888325219,"sku":"IC695CMU310","price":560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC695CRU320_1.png?v=1741071560"},{"product_id":"ge-fanuc-ic695cpu320-pacsystems-rx3i-cpu-module","title":"GE Fanuc IC695CPU320 PACSystems RX3i CPU Module","description":"\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCPU Performance:\u003c\/strong\u003e\u003cbr\u003eFor detailed performance data, refer to Appendix A of the PACSystems CPU Reference Manual, GFK-2222V or later.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBattery: Memory Retention:\u003c\/strong\u003e\u003cbr\u003eFor battery selection, installation, and estimated life, refer to the PACSystems RX3i and RX7i Battery Manual, GFK-2741.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgram Storage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 64 MB of battery-backed RAM\u003c\/li\u003e\n\u003cli\u003e64 MB of non-volatile flash user memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e+3.3 VDC: 1.0 Amps nominal\u003c\/li\u003e\n\u003cli\u003e+5 VDC: 1.2 Amps nominal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cbr\u003e0 to 60°C (32°F to 140°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFloating Point Support:\u003c\/strong\u003e\u003cbr\u003eYes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTime of Day Clock Accuracy:\u003c\/strong\u003e\u003cbr\u003eMaximum drift of 2 seconds per day\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElapsed Time Clock (Internal Timing) Accuracy:\u003c\/strong\u003e\u003cbr\u003e0.01% maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEmbedded Communications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRS-232\u003c\/li\u003e\n\u003cli\u003eRS-485\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSerial Protocols Supported:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eModbus RTU Slave\u003c\/li\u003e\n\u003cli\u003eSNP\u003c\/li\u003e\n\u003cli\u003eSerial I\/O\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Support:\u003c\/strong\u003e\u003cbr\u003eDual backplane bus support: RX3i PCI and high-speed serial bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePCI Compatibility:\u003c\/strong\u003e\u003cbr\u003eSystem designed to be electrically compliant with PCI 2.2 standard\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgram Blocks:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 512 program blocks\u003c\/li\u003e\n\u003cli\u003eMaximum size for a block: 128 KB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Configurations:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e%I and %Q: 32Kbits for discrete\u003c\/li\u003e\n\u003cli\u003e%AI and %AQ: Configurable up to 32K words\u003c\/li\u003e\n\u003cli\u003e%W: Configurable up to the maximum available user RAM\u003c\/li\u003e\n\u003cli\u003eSymbolic: Configurable up to 64 MB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42630897991779,"sku":"IC695CPU320","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC695CPE330_3.jpg?v=1741072946"},{"product_id":"ic698chs009-ge-fanuc-rx7i-pacsystem-i-o-rack","title":"IC698CHS009 | GE Fanuc | Rx7i PACsystem I\/O Rack","description":"\u003ch2\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe GE IC698CHS009 is an expansion module designed for use with GE Fanuc's programmable logic controllers (PLCs). It expands the I\/O capabilities of the PLC system by adding additional channels for interfacing with external devices. This module is essential for scaling up the control system to meet more complex automation needs.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpansion Capability\u003c\/strong\u003e: Adds extra I\/O channels to the existing PLC setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Specifically designed for use with GE Fanuc PLC systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Design\u003c\/strong\u003e: Can be easily integrated into existing PLC racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Construction\u003c\/strong\u003e: Built to withstand industrial environments and ensure reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Performance\u003c\/strong\u003e: Provides additional channels to improve system functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Expansion Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number\u003c\/strong\u003e: IC698CHS009\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: General Electric (GE)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e: GE Fanuc PLC systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Channels\u003c\/strong\u003e: Depends on the specific module configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements\u003c\/strong\u003e: Varies based on installation and configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e: Typically from 0°C to 60°C (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: Specific dimensions vary by model, generally designed for standard PLC racks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Designed for DIN rail or rack mounting\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42714013761635,"sku":"IC698CHS009","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC698CHS009.jpg?v=1741071338"},{"product_id":"ge-fanuc-ic698etm001-ethernet-interface-module","title":"GE Fanuc IC698ETM001 Ethernet Interface Module","description":"\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe GE Fanuc IC698ETM001 is an Ethernet interface module designed to deliver high-performance Ethernet communications for RX7i control systems. It operates at an Ethernet processing speed of 200 MHz and requires a +5 VDC power supply with a maximum current draw of 1.5A. This module facilitates TCP\/IP communications with other GE Intelligent Platforms control systems and host computers, providing robust Ethernet connectivity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Configuration and Programming Services:\u003c\/strong\u003e Allows complete configuration and programming through Ethernet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Global Data (EGD):\u003c\/strong\u003e Supports intermittent data exchange with EGD Class 2 functionality and Reliable Data Service (RDS) for accurate command message communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStation Management and Diagnostic Tools:\u003c\/strong\u003e Includes comprehensive management and diagnostic capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull-Duplex Ports:\u003c\/strong\u003e Features auto-negotiated network speed and crossover detection via an internal network switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant IP Addressing:\u003c\/strong\u003e Enables assigning a redundant IP address to two Ethernet modules in different controllers, with only the active unit's interface using the redundant IP.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Processor Speed:\u003c\/strong\u003e 200 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Operating Voltage:\u003c\/strong\u003e +5 VDC (from power supply)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Current Drain:\u003c\/strong\u003e 1.5A maximum; 1.2A typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Operating Temperature:\u003c\/strong\u003e 0°C to +60°C (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLEDs:\u003c\/strong\u003e MODULE OK, LAN ONLINE STATUS, 100 LINK P1, 100 LINK P2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEEE Standards:\u003c\/strong\u003e IEEE 802.2 Logical Link Control Class I, IEEE 802.3 CSMA\/CD Medium Access Control 10\/100 Mbps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet and Connectivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of IP Addresses:\u003c\/strong\u003e One\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Ports:\u003c\/strong\u003e Two, 10BaseT \/ 100BaseTX with auto-sensing, RJ-45 connector, 8-pin female, shielded\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmbedded Ethernet Switch:\u003c\/strong\u003e Yes, for daisy chaining of Ethernet nodes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Port (Station Manager Port):\u003c\/strong\u003e RS-232 DCE, 1200 - 115200 bps, D-connector, 9-pin female\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Versamax\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e IC698ETM001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Ethernet Interface Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Processor Speed:\u003c\/strong\u003e 200 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 5 Volts DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 1.5 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to 60 degrees Celsius\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of IP Addresses:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Ports:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42714021986403,"sku":"IC698ETM001","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC698ETM001_2.jpg?v=1741071337"},{"product_id":"ge-fanuc-ic698rmx016-redundancy-module","title":"GE Fanuc IC698RMX016 Redundancy Module","description":"\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe GE Fanuc IC698RMX016 is a 16MB Redundant Memory Xchange module for the RX7i PACSystems. It features a fiber optic LC connector, 16MB of SDRAM user memory, and operates at +5 V DC with a current requirement of 1.8A. The module's physical dimensions are 6.299 inches wide by 9.187 inches high. It supports a temperature range from -20°C to +85°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Size:\u003c\/strong\u003e 6.299” W x 9.187” H\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser Memory:\u003c\/strong\u003e 16MB SDRAM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e +5VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Requirements:\u003c\/strong\u003e 1.8A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectors:\u003c\/strong\u003e Fiber optic LC type, zirconium ceramic ferrule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsertion Loss:\u003c\/strong\u003e 0.35 dB (maximum)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReturn Loss:\u003c\/strong\u003e -30dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -20°C to +85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e RX7i PACSystems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e IC698RMX016\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Redundancy Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications:\u003c\/strong\u003e Reflective network, hot standby CPU redundancy system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReflective Memory:\u003c\/strong\u003e 128 MB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptic Network Speed:\u003c\/strong\u003e 2.12 Gbaud\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransfer Rate:\u003c\/strong\u003e 2.1 GB\/s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Insertion:\u003c\/strong\u003e Supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Error Detection:\u003c\/strong\u003e Supported\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation and Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure the PACSystems RX7i CPU has release 2.00 or later firmware and the required components are in place before installation. The module should be installed in RX7i Rack 0, ideally in slots 4 and 3 for priority. Power off the rack before inserting the module, connect the fiber optic cables as per the ring topology, and power on the system. Configuration parameters include Redundant Transfer Mode, Node ID, Network Memory Offset, Rogue Master, and Interrupt enable.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42714028441699,"sku":"IC698RMX016","price":460.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC698RMX016.jpg?v=1741071336"},{"product_id":"ge-fanuc-ic698cre030-rx7i-central-processing-unit","title":"GE Fanuc IC698CRE030 RX7i Central Processing Unit","description":"\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC698CRE030 is a PACSystems RX7i Central Processing Unit designed for real-time control of machines, processes, and systems. The CPU communicates with I\/O and smart option modules via a rack-mounted backplane utilizing the VME64 Standard format. It features a 600MHz Pentium-M microprocessor, with 64 MB of user memory and flash memory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSB or Hot Standby Redundancy:\u003c\/strong\u003e Ensures continuous operation with redundant systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e Battery-backed user memory and non-volatile flash memory for program, configuration, register data, and symbolic variable storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming Languages:\u003c\/strong\u003e Supports Ladder Diagram, C, Structured Text, and Function Block Diagram.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSymbolic Variables:\u003c\/strong\u003e Auto-located, using unlimited memory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Support:\u003c\/strong\u003e Compatible with 90-70 Series discrete and analog I\/O, as well as VME modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb-Based Monitoring:\u003c\/strong\u003e Allows data monitoring across the web with up to 16 web server\/FTP connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlock Size and Program Blocks:\u003c\/strong\u003e Maximum block size of 128KB, supporting up to 512 program blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmbedded Ethernet Interface:\u003c\/strong\u003e Facilitates EGD data exchange, TCP\/IP communication, and time synchronization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing Speed:\u003c\/strong\u003e 600 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPU Memory:\u003c\/strong\u003e 64 Mbytes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloating Point Support:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Ports:\u003c\/strong\u003e 3 (RS-232, RS-485)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Protocols:\u003c\/strong\u003e Modbus RTU Slave, SNP, Serial I\/O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmbedded Communications:\u003c\/strong\u003e Ethernet interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e+5 VDC:\u003c\/strong\u003e 3.2 Amps nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e+12 VDC:\u003c\/strong\u003e 0.003 Amps nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-12 VDC:\u003c\/strong\u003e 0.003 Amps nominal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCRE030:\u003c\/strong\u003e 0 to 50°C (32°F to 122°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCRE040:\u003c\/strong\u003e 0 to 60°C (32°F to 140°F) with fan tray\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBoolean Execution Speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCRE030:\u003c\/strong\u003e 0.069ms per 1000 Boolean contacts\/coils\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCRE040:\u003c\/strong\u003e 0.024ms per 1000 Boolean contacts\/coils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eClock Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime of Day Clock:\u003c\/strong\u003e ±2 seconds per day maximum drift\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElapsed Time Clock:\u003c\/strong\u003e ±0.01% maximum accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMemory and Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgram Blocks:\u003c\/strong\u003e Up to 512 blocks, each with a maximum size of 128KB.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Areas:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e%I and %Q: 32Kbits for discrete\u003c\/li\u003e\n\u003cli\u003e%AI and %AQ: Configurable up to 32Kwords\u003c\/li\u003e\n\u003cli\u003e%W: Configurable up to maximum available user RAM\u003c\/li\u003e\n\u003cli\u003eManaged Memory (Symbolic and I\/O variables combined): Configurable up to 10 Mbytes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet Interface Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Rate:\u003c\/strong\u003e 10Mb\/sec and 100Mb\/sec\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Interface:\u003c\/strong\u003e 10BaseT RJ45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb-Based Monitoring:\u003c\/strong\u003e Up to 16 web server and FTP connections combined\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime Synchronization:\u003c\/strong\u003e SNTP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWinLoader Support:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEGD Configuration Pages:\u003c\/strong\u003e Up to 255\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelective Consumption of EGD:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Station Manager:\u003c\/strong\u003e Over UDP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal Station Manager:\u003c\/strong\u003e Dedicated RS-232 port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Advanced User Parameters:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42714036895843,"sku":"IC698CRE030","price":460.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC698CRE030.jpg?v=1741071335"},{"product_id":"ic698cpe030-ge-fanuc-central-processing-unit","title":"IC698CPE030 | GE Fanuc | Central Processing Unit","description":"\u003ch2\u003e\u003cstrong\u003eIC698CPE030 Product Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe IC698CPE030 is a 600 MHz CPU from GE Fanuc designed for the RX7i series. It features battery-backed user memory and non-volatile flash memory, ensuring reliable data storage and program retention. The CPU includes a Pentium-M microprocessor and supports Series 90-70 I\/O, communications, and VME modules. It utilizes a VME64 standard format for I\/O communication and offers embedded Ethernet ports and a serial port with SNP Slave protocol for connectivity.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing Speed:\u003c\/strong\u003e 600 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPU Memory:\u003c\/strong\u003e 64 MB (user RAM and flash)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloating Point:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Ports:\u003c\/strong\u003e 3 (RS-485, RS-232, RS-232 Ethernet station manager)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Protocols:\u003c\/strong\u003e Modbus RTU Slave, SNP, Serial I\/O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmbedded Communications:\u003c\/strong\u003e RS-232, RS-485, Ethernet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e+5 VDC:\u003c\/strong\u003e 3.2 Amps nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e+12 VDC:\u003c\/strong\u003e 0.003 Amps nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-12 VDC:\u003c\/strong\u003e 0.003 Amps nominal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPE030:\u003c\/strong\u003e 0 to 50°C (32°F to 122°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPE040:\u003c\/strong\u003e 0 to 60°C (32°F to 140°F) with fan tray required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eBoolean Execution Speed\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPE030:\u003c\/strong\u003e 0.069 ms per 1000 Boolean contacts\/coils\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPE040:\u003c\/strong\u003e 0.02391 ms per 1000 Boolean contacts\/coils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTimekeeping and Memory\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime of Day Clock Accuracy:\u003c\/strong\u003e ±2 seconds per day\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElapsed Time Clock Accuracy:\u003c\/strong\u003e ±0.01% maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e Up to 64 MB battery-backed RAM and non-volatile flash memory\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgram Blocks:\u003c\/strong\u003e Up to 512, 128KB max size per block\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eEthernet Interface Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Rate:\u003c\/strong\u003e 10Mb\/sec and 100Mb\/sec\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Interface:\u003c\/strong\u003e 10BaseT RJ45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb-Based Monitoring:\u003c\/strong\u003e Up to 16 web server and FTP connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime Synchronization:\u003c\/strong\u003e SNTP\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42714039255139,"sku":"IC698CPE030","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC698CPE030.jpg?v=1741071335"},{"product_id":"ge-he693cpu701-central-processing-unit-module","title":"GE HE693CPU701 Central Processing Unit Module","description":"\u003cp\u003e\u003cstrong\u003eTechnical Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eHorner Electric HE693CPU701\u003c\/strong\u003e PLC I\/O Module, featuring an Ethernet port, is part of the Horner Automation APG product line. It is compatible with GE Fanuc Series 90-30 or Series 90-70 Programmable Logic Controllers (PLCs).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Ports\u003c\/strong\u003e: Includes 2 serial ports, one with 9 terminal points and another with 15 terminal points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Connectivity\u003c\/strong\u003e: Equipped with an RJ45 EtherNet connector for remote control and monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Flash Memory\u003c\/strong\u003e: Features a built-in 63 MB Compact Flash memory unit (part number 46-164-64R) for backing up and restoring logic programming data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction\u003c\/strong\u003e: Open-style plastic casing with an environmental protection rating of IP 20.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation and Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation\u003c\/strong\u003e: Although the module has a built-in ventilation fan, it is recommended to install it inside a protective enclosure with forced ventilation or a compatible climate control system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Updates\u003c\/strong\u003e: Includes a USB connector for firmware updates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicators\u003c\/strong\u003e: Four LEDs on the top and front indicate various device statuses and applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuthorized Personnel\u003c\/strong\u003e: Only qualified individuals should perform installation, maintenance, repair, or troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42715646492771,"sku":"HE693CPU701","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/HE693CPU701.jpg?v=1741071325"},{"product_id":"ge-fanuc-ic694alg223-analog-input-module","title":"GE Fanuc IC694ALG223 Analog Input Module","description":"\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC694ALG223\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 16-channel analog current input module designed for mission-critical discrete and process applications. It offers advanced diagnostics and outstanding flexibility, with a wide range of standard and advanced I\/O.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e16 single-ended inputs\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ranges\u003c\/strong\u003e: 0-20 mA, 4-20 mA, and 4-20 mA Enhanced\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh and low alarm limits\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor all ranges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen-wire fault detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein 4-20 mA applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule status and external power supply status\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ereporting to the CPU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED indicators\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor module status and external 24 VDC supply status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Input Count \u0026amp; Type\u003c\/strong\u003e: 16 Channel; 4-20mA; 0-20mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution \u0026amp; Speed\u003c\/strong\u003e: 12 Bit; 13mS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e: 120mA @5VDC; 65mA User Supplied 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e: UL, UL HAZLOC, CE, ATEX C1D2, ABS, BV, DNV, GL, KRS, LR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Format\u003c\/strong\u003e: On Panel\/DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration\u003c\/strong\u003e: Factory calibrated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e: 13 milliseconds (all 16 channels)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution at 4-20 mA\u003c\/strong\u003e: 4 μA (4 μA\/bit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution at 0-20 mA\u003c\/strong\u003e: 5 μA (5 μA\/bit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute Accuracy\u003c\/strong\u003e: +\/-0.25% of full scale @ 25°C (77°F); +\/- 0.5% of full scale over specified operating temperature range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation, Field to Backplane\u003c\/strong\u003e: 250 VAC continuous; 1500 VAC for 1 minute (optical) and to frame ground\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance\u003c\/strong\u003e: 250 Ohms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Low Pass Filter\u003c\/strong\u003e: 19 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Supply Voltage\u003c\/strong\u003e: 20 to 30 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42820725538915,"sku":"IC694ALG223","price":538.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC694ALG223.png?v=1741070914"},{"product_id":"ge-fanuc-ic695cmm002-serial-communications-module","title":"GE Fanuc IC695CMM002 Serial Communications Module","description":"\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695CMM002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a serial communications module developed by GE Fanuc for the RX3i PACSystems PLCs. It enhances communication capabilities by supporting various serial communication protocols, making it ideal for a wide range of industrial applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eTwo independent serial ports\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSupports RS-232\/485 communication\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSupports Serial Read\/Write and Modbus Master\/Slave\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHot swap capability\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAdvanced diagnostics\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHigh-speed and patented technology for faster throughput\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Serial Ports\u003c\/strong\u003e: Two isolated RS-232\/485 ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e: Serial Read\/Write, Modbus Master\/Slave\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Format\u003c\/strong\u003e: Requires Universal Backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e: UL, CE, ATEX, IECEx\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements\u003c\/strong\u003e: 5V DC, 3.3V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0°C to 60°C (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°C to 85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity\u003c\/strong\u003e: 5% to 95% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42820770562147,"sku":"IC695CMM002","price":506.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC695CMM002.jpg?v=1741070913"},{"product_id":"is200aepch1ccb-ge-mark-vi-is200aepch1ccb-speedtronic-turbine-control-pcb-boar","title":"IS200AEPCH1CCB | GE Mark VI IS200AEPCH1CCB Speedtronic Turbine Control PCB Board","description":"\u003ch2\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe AMAT 0010-27983 is a 300MM MCA E-CHUCK ESC Heater designed for semiconductor manufacturing. It plays a critical role in wafer processing by controlling and maintaining the temperature of the electrostatic chuck (ESC), ensuring precise heating for consistent wafer quality.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProvides precise and uniform heating\u003c\/li\u003e\n\u003cli\u003eHigh temperature capability\u003c\/li\u003e\n\u003cli\u003eDesigned for long service life\u003c\/li\u003e\n\u003cli\u003eSuitable for semiconductor manufacturing processes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e300MM MCA E-CHUCK ESC Heater\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e135 x 186 x 119 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.2 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemiconductor manufacturing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHeats and regulates ESC temperature during wafer processing\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42924151799907,"sku":"IS200AEPCH1CCB","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IS200AEPCH1CCB_1.jpg?v=1741070249"},{"product_id":"ic694mdl645-ge-fanuc-pacsystem-rx3i-discrete-input-module","title":"IC694MDL645 | GE Fanuc | PACSystem RX3i Discrete Input Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIC694MDL645\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 16-channel discrete input module from GE Fanuc's PACSystem RX3i series, designed for industrial control systems with flexible input configurations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 (1 group)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC (positive or negative logic)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7 mA per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn State Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e11.5 to 30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff State Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to +5 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e80 mA @ 5VDC; 125 mA @ 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7 ms (typical and maximum)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 to 140°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40 to 185°F\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePositive or Negative Logic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0-30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Lifecycle:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eActive\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Consumption\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current Draw:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e80 mA @ 5VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e125 mA from 24 VDC supply\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42984145092707,"sku":"IC694MDL645","price":225.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC694MDL645.jpg?v=1741070039"},{"product_id":"ic695psd040-general-electric-pacsystems-rx3i-dc-power-supply","title":"IC695PSD040 General Electric | PACSystems RX3i DC Power Supply","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695PSD040\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a General Electric PACSystems RX3i DC Power Supply module providing 40 watts of output power. It supports input voltage ranges from 12 to 30 VDC and delivers output voltages of 5.1 VDC and 3.3 VDC. This power supply includes multiple LED indicators for fault detection and has robust wiring capabilities.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Rated Voltage\u003c\/strong\u003e: 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eStart: 18 to 30 VDC\u003c\/li\u003e\n\u003cli\u003eRun: 12 to 30 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power\u003c\/strong\u003e: 60 watts maximum at full load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current\u003c\/strong\u003e: 4 amps, 100 milliseconds maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Power\u003c\/strong\u003e: 40 watts maximum total\n\u003cul\u003e\n\u003cli\u003e5.1 VDC: 30 watts maximum\u003c\/li\u003e\n\u003cli\u003e3.3 VDC: 30 watts maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e5.1 VDC: 5.0 to 5.2 VDC (nominal 5.1 VDC)\u003c\/li\u003e\n\u003cli\u003e3.3 VDC: 3.1 to 3.5 VDC (nominal 3.3 VDC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e5.1 VDC: 0 to 6 amps\u003c\/li\u003e\n\u003cli\u003e3.3 VDC: 0 to 9 amps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRipple\/Noise (All Outputs)\u003c\/strong\u003e: 50 mV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRide-Through Time\u003c\/strong\u003e: 10 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Terminals\u003c\/strong\u003e: Accepts 14 AWG to 22 AWG wires\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower\u003c\/strong\u003e: Green (power supplied), Amber (power on but switch off)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP\/S Fault\u003c\/strong\u003e: Red (power supply failure)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver Temperature\u003c\/strong\u003e: Amber (near or exceeding max operating temperature)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload\u003c\/strong\u003e: Amber (exceeding output capability)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn\/Off Switch\u003c\/strong\u003e: Located behind the door, prevents accidental switching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Current\u003c\/strong\u003e: 6 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaisy-Chaining Capability\u003c\/strong\u003e: Up to 2 PSD040 supplies\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42984149811299,"sku":"IC695PSD040","price":260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC695PSD040_1.jpg?v=1741070036"},{"product_id":"ge-fanuc-ic695alg808-isolated-analog-output-module","title":"GE Fanuc | IC695ALG808 | Isolated Analog Output Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC695ALG808\u003c\/strong\u003e is an isolated analog output module for the Rx3i PACSystem. It features 8 output channels with a wide range of current and voltage outputs, offering flexibility in industrial automation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Ranges\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eCurrent: 0-20mA, 4-20mA\u003c\/li\u003e\n\u003cli\u003eVoltage: +\/-10V, 0-10V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eBackplane: 80mA at 3.3V\u003c\/li\u003e\n\u003cli\u003eExternal: 19.2V to 30V (600mA max)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e+\/-10V: 15.9 bits\u003c\/li\u003e\n\u003cli\u003e0 to 10V: 14.9 bits\u003c\/li\u003e\n\u003cli\u003e0 to 20mA: 15.9 bits\u003c\/li\u003e\n\u003cli\u003e4 to 20mA: 15.6 bits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e0.15% FS at 25°C\u003c\/li\u003e\n\u003cli\u003e0.25% FS at 60°C\u003c\/li\u003e\n\u003cli\u003eDegrades to +\/-1% FS with severe RF interference\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e: Approx. 8ms (dependent on I\/O scan time)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSettling Time\u003c\/strong\u003e: 2ms (0 to 95%)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eCurrent: -30V for 60s, +30V for 1 hour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation\u003c\/strong\u003e: 2550VDC for 1 second\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Derating\u003c\/strong\u003e: Refer to derating curves\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Load\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eCurrent: 1350 Ohms max\u003c\/li\u003e\n\u003cli\u003eVoltage: 2 Kohms min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43018106634339,"sku":"IC695ALG808","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC695ALG808_2.jpg?v=1741069852"},{"product_id":"pacsystem-rx3i-ic695cpe305-ge-fanuc-controller-module","title":"PACSystem RX3i  IC695CPE305 | GE Fanuc Controller Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC695CPE305\u003c\/strong\u003e is a PACSystem RX3i CPU module from GE Fanuc. It offers a high-speed 1.1 GHz processor with 5MB RAM and 5MB non-volatile memory, making it ideal for demanding automation tasks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor Speed\u003c\/strong\u003e: 1.1 GHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRAM\u003c\/strong\u003e: 5MB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-volatile Memory\u003c\/strong\u003e: 10MB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitchover Time\u003c\/strong\u003e: 1 logic scan (min. 3.133 ms)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Port\u003c\/strong\u003e: 10\/100 Mbps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Ports\u003c\/strong\u003e: 2 (RS232, RS485)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB 2.0 Master Port\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Program Blocks\u003c\/strong\u003e: 512\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Block Size\u003c\/strong\u003e: 128KB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e1 Amp at +5V, +3.3V DC\u003c\/li\u003e\n\u003cli\u003e0.5 Amps at +24V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloating Point Support\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols Supported\u003c\/strong\u003e: Modbus RTU Slave, SNP, Serial I\/O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane\u003c\/strong\u003e: Universal backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Slots\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Local Racks\u003c\/strong\u003e: 8\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet\u003c\/strong\u003e: Supports PROFINET, Modbus TCP, and OPC UA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Ports\u003c\/strong\u003e: RS-232, RS-485\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB Port\u003c\/strong\u003e: For program download\/upload from thumb drives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols\u003c\/strong\u003e: Ethernet, Genius, DeviceNet, PROFIBUS DP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Protocols\u003c\/strong\u003e: Ethernet Global Data, Modbus TCP, and more\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e: PCI 2.2 standard, RX3i Series PCI devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpandability\u003c\/strong\u003e: Supports additional communication cards for Serial, Genius, CMX, and Ethernet\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43018107584611,"sku":"IC695CPE305","price":225.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC695CPE305_2.jpg?v=1741069851"},{"product_id":"ic694mdl740-ge-fanuc-pacsystem-rx3i-positive-logic-output-module","title":"IC694MDL740 | GE Fanuc | PACsystem RX3i Positive Logic Output Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC694MDL740\u003c\/strong\u003e is a PACsystem RX3i Positive Logic output module featuring 16 discrete channels. It operates with a voltage range of 12-24 VDC, providing 0.5 Amps per point and 2 Amps per module. The module draws 110 mA when all outputs are active.\u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e: 12 to 24 VDC (+20%, -15%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current\u003c\/strong\u003e: 0.5 Amps per point, 2 Amps per module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Drop\u003c\/strong\u003e: 0.5 V maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current\u003c\/strong\u003e: 4.78 A for 10 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Isolation Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 110 mA (all outputs on) from 5V DC bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation\u003c\/strong\u003e: 250 VAC continuous (Field to Backplane, optical), 1500 VAC for 1 minute (Field to Frame Ground), 250 VAC continuous, 1500 VAC for 1 minute (Group to Group)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn\/Off Response Time\u003c\/strong\u003e: 2 ms maximum (both on and off)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Leakage\u003c\/strong\u003e: 1 mA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicators\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: PACSystem RX3i\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Configuration\u003c\/strong\u003e: Positive Logic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Channels\u003c\/strong\u003e: 16 channels in two groups of 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e: 12 \/ 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifecycle Status\u003c\/strong\u003e: Active\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43036360048739,"sku":"IC694MDL740","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC694MDL740_2.jpg?v=1741069765"},{"product_id":"pacsystem-rx3i-ic694mdl340-ge-fanuc-discrete-output-module","title":"PACsystem RX3i | IC694MDL340 | GE Fanuc Discrete Output Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC694MDL340\u003c\/strong\u003e is a discrete output module for the PACsystem RX3i, with 16 channels (2 groups of 8). It provides reliable 120 VAC output with high inrush current handling.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 85-132 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent per Channel:\u003c\/strong\u003e 0.5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Groups:\u003c\/strong\u003e 2, each with 8 channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current:\u003c\/strong\u003e 20 A for 1 cycle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 250 VAC continuous, 1500 VAC for 1 minute\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Areas\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUsed to control AC-driven devices like motors and relays\u003c\/li\u003e\n\u003cli\u003eApplicable in automation systems for industrial processes\u003c\/li\u003e\n\u003cli\u003eIdeal for managing high-power loads in manufacturing settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e On 1 ms, Off ½ cycle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current:\u003c\/strong\u003e 2 mA max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Status\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifecycle:\u003c\/strong\u003e Active\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43036483977315,"sku":"IC694MDL340","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC694MDL340_2.jpg?v=1741069761"},{"product_id":"ge-fanuc-ic695chs012-pacsystem-rx3i-universal-backplane","title":"GE Fanuc | IC695CHS012 | PACSystem RX3i Universal Backplane","description":"\u003ch3\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIC695CHS012\u003c\/strong\u003e is a PACSystem RX3i Universal Backplane by GE Fanuc, compatible with RX3i PACSystem, Series 90-30, and option modules.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: RX3i PACSystem\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number\u003c\/strong\u003e: IC695CHS012\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Universal backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Slots\u003c\/strong\u003e: 12\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePower and Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Power (5 VDC)\u003c\/strong\u003e: 240 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Power (3.3 VDC)\u003c\/strong\u003e: 600 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: +24 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Support\u003c\/strong\u003e: PCI and High-Speed Serial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Swap Support\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Rack-mounted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation\u003c\/strong\u003e: Horizontal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance\u003c\/strong\u003e: Minimum 102 mm (4 inches) on all sides\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection\u003c\/strong\u003e: NEMA\/UL Type 1 (IP20)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize (HxWxD)\u003c\/strong\u003e: 141.4 x 457.2 x 147.3 mm (5.5 x 18 x 5.8 inches)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43112249163875,"sku":"IC695CHS012","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC695CHS012_1.jpg?v=1741069337"},{"product_id":"ic695chs016-pacsystem-rx3i-ge-fanuc-universal-backplane","title":"IC695CHS016 | PACSystem RX3i GE Fanuc Universal Backplane","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC695CHS016\u003c\/strong\u003e is a universal backplane designed for the PACSystem RX3i and Series 90-30 I\/O modules. It supports a variety of modules and facilitates connectivity with PCI and Serial Bus connectors, providing a reliable backbone for modular I\/O systems. \u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Slots\u003c\/strong\u003e: 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e600 mA at 3.3 VDC\u003c\/li\u003e\n\u003cli\u003e240 mA at 5 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput\u003c\/strong\u003e: +24 Volts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Connectors\u003c\/strong\u003e: PCI Bus \/ Serial Bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 141.4 mm (5.5 inches)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 602 mm (23.7 inches)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth\u003c\/strong\u003e: 147.3 mm (5.8 inches)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired Protection\u003c\/strong\u003e: NEMA\/UL Type 1 (IP20)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Required Clearance\u003c\/strong\u003e: 102 mm (4 inches) on all sides\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Wire Size\u003c\/strong\u003e: 14 to 22 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e: Horizontal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Orientation\u003c\/strong\u003e: Horizontal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: IP54 or greater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower and Terminals\u003c\/h3\u003e\n\u003cul data-is-last-node=\"\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Power Consumption\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e240 mA at 5 Volts DC\u003c\/li\u003e\n\u003cli\u003e600 mA at 3.3 Volts DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-is-last-node=\"\"\u003e\n\u003cstrong\u003eInput Terminals\u003c\/strong\u003e:\n\u003cul data-is-last-node=\"\"\u003e\n\u003cli\u003eTB1; Terminal 7: Isolated 24VDC\u003c\/li\u003e\n\u003cli data-is-last-node=\"\"\u003eTerminal 8: Isolated ground\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43174299861091,"sku":"IC695CHS016","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC695CHS016.jpg?v=1741069151"},{"product_id":"ge-fanuc-ic694mdl754-positive-logic-discrete-output-module","title":"GE Fanuc IC694MDL754 Positive Logic Discrete Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC694MDL754\u003c\/strong\u003e is a high-density discrete output module designed for use with the PACSystem RX3i platform. It offers 32 positive logic discrete outputs and provides high reliability with built-in protection features. Ideal for applications requiring fast response times and robust protection, this module is optimized for use in industrial automation systems.\u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e: 32\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Output Groups\u003c\/strong\u003e: 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e: 10.2 - 30.0 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 12\/24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current\u003c\/strong\u003e: 0.75 Amps per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (Maximum)\u003c\/strong\u003e: 0.5 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage Drop\u003c\/strong\u003e: 0.3 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Voltage Leakage\u003c\/strong\u003e: 0.1 mA, maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Configuration\u003c\/strong\u003e: Positive Logic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoint-to-Point Isolation\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection and Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in Protection\u003c\/strong\u003e: Short-circuit, overcurrent, and overtemperature protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Rating\u003c\/strong\u003e: 3.0 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Current Draw from Backplane\u003c\/strong\u003e: 300 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Backplane Draw\u003c\/strong\u003e: 300 milliamps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Terminal Blocks\u003c\/strong\u003e: Box-style (IC694TBB032) \/ Spring-style (IC694TBS032)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Features\u003c\/h3\u003e\n\u003cul data-is-last-node=\"\"\u003e\n\u003cli data-is-last-node=\"\"\u003e\n\u003cstrong\u003eLocation\u003c\/strong\u003e: RX3i PACSystems I\/O slot\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43174304120931,"sku":"IC694MDL754","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC694MDL754_1.jpg?v=1741069150"},{"product_id":"ic695cbl002-ge-fanuc-pacsystems-rx3i-cable","title":"IC695CBL002 GE Fanuc PACSystems RX3i | Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number\u003c\/strong\u003e: \u003cstrong\u003eIC695CBL002\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Replacement cable for CPU connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with\u003c\/strong\u003e: PACSystems RX3i\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Operational\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range\u003c\/strong\u003e: 120\/240 Volts, 125 Volts DC, or 24 Volts DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Pack Compliance\u003c\/strong\u003e: EU RoHS directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Input\/Output\u003c\/strong\u003e: Analog\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Properties\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: 1 meter (36 inches)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector\u003c\/strong\u003e: 7-pin, keyed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e: Straight-through end-to-end\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to 60°C (32 to 140°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Features\u003c\/h3\u003e\n\u003cul data-is-last-node=\"\"\u003e\n\u003cli data-is-last-node=\"\"\u003e\n\u003cstrong\u003eTermination Resistor\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43174315982947,"sku":"IC695CBL002","price":60.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC695CBL002_2.jpg?v=1741069143"},{"product_id":"ic695acc402-energy-pack-unit-ge-fanuc","title":"IC695ACC402 Energy Pack Unit | GE Fanuc","description":"\u003ch3\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC695ACC402 Energy Pack Unit\u003c\/strong\u003e from GE Fanuc's PACSystem RX3i series ensures reliable data retention during power failures. Designed for use with the \u003cstrong\u003eRX3i CPE330 CPU\u003c\/strong\u003e, it mounts on a \u003cstrong\u003eDIN rail\u003c\/strong\u003e or \u003cstrong\u003epanel\u003c\/strong\u003e and operates via the \u003cstrong\u003ePLC backplane\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e: 18-30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e: 20–30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e: 18-30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e: 24 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Output Power\u003c\/strong\u003e: 45 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power, Maximum\u003c\/strong\u003e: 36 W + connected device power requirement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility \u0026amp; Mounting\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Series\u003c\/strong\u003e: PACSystem RX3i\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible CPU\u003c\/strong\u003e: RX3i CPE330 CPU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Controller\u003c\/strong\u003e: CPE 330\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: DIN rail \/ Panel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-is-last-node=\"\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Source\u003c\/strong\u003e: PLC Backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePurpose\u003c\/strong\u003e: Saves CPU data during power failures\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicators\u003c\/strong\u003e: IN, STAT, OUT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround Strap\u003c\/strong\u003e: Included\u003c\/li\u003e\n\u003cli data-is-last-node=\"\"\u003e\n\u003cstrong\u003eDedicated Cable\u003c\/strong\u003e: \u003cstrong data-is-last-node=\"\"\u003eIC695CBL002 Cable\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43176182382691,"sku":"IC695ACC402","price":210.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC695ACC402_1.jpg?v=1741069113"},{"product_id":"ic698cpe010-cc-ge-fanuc-cpu","title":"IC698CPE010-CC | GE Fanuc | CPU","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eIC698CPE010-CC\u003c\/strong\u003e Central Processing Unit by GE Fanuc is a high-performance CPU from the RX7i series, designed to control industrial machinery and material processes in real-time. It communicates with other devices and modules through a VME64 connection backplane mounted to the rack.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eGeneral Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct ID:\u003c\/strong\u003e IC698CPE010-CC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Fanuc\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e RX7i\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProcessing Speed:\u003c\/strong\u003e 300 MHz (Celeron microprocessor)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCPU Memory:\u003c\/strong\u003e 10 Mbytes RAM (CMOS battery-backed)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFloating Point Calculations:\u003c\/strong\u003e Yes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSerial Ports:\u003c\/strong\u003e 3 embedded serial ports\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Ports:\u003c\/strong\u003e 2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e 10 Mbytes non-volatile flash memory (NVRAM)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStandard Speed of Boolean Function:\u003c\/strong\u003e 0.33ms per coil\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBit-in-Word Reference Support:\u003c\/strong\u003e Yes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSymbolic Variable Support:\u003c\/strong\u003e Yes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTest Edit Mode:\u003c\/strong\u003e Yes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Monitoring over Web:\u003c\/strong\u003e Yes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating System Firmware Data:\u003c\/strong\u003e Stored in flash memory (firmware updatable without disassembly)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommunication Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEmbedded Comms:\u003c\/strong\u003e RS-232, RS-485, Ethernet interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSerial Protocols:\u003c\/strong\u003e Modbus RTU Slave, SNP, Serial I\/O\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration and Programming:\u003c\/strong\u003e Proficy Machine Edition PLC-Logic Developer software\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration Data Security:\u003c\/strong\u003e Password-secured\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43237578113123,"sku":"IC698CPE010-CC","price":280.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC698CPE010-CC.jpg?v=1741865774"},{"product_id":"ge-fanuc-ic695cpl410-aaac-rackless-cpu","title":"GE Fanuc IC695CPL410-AAAC Rackless CPU","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695CPL410-AAAC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a GE Fanuc RX3i Rackless CPU designed for PACSystems, offering high-performance control and flexible programming.\u003c\/p\u003e\n\u003ch3\u003eMemory \u0026amp; Programming\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData \u0026amp; Program Memory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e64 MB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgram Blocks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 768\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Block Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e128 KB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgramming Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLadder Diagram, Function Block Diagram, Structured Text\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommunication\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet LAN Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 4 LANs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3 front-panel ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUSB Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 USB 3.0 ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSerial COM Port:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRJ45\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMounting \u0026amp; Installation\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN Rail or Panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43588639260771,"sku":"IC695CPL410-AAAC","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/IC695CPL410-AAAC_2.jpg?v=1755080239"},{"product_id":"259b2460btg2-ge-mark-vi-speedtronic-datasheet-technical-manual","title":"259B2460BTG2 GE Mark VI Speedtronic Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eGE 259B2460BTG2 Rack Chassis Module Backplane Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for module hosting and internal power distribution within GE Mark VI Turbine Control Systems, the \u003cstrong\u003eGE 259B2460BTG2\u003c\/strong\u003e (\u003cstrong\u003e512AZSPBPAC-100\u003c\/strong\u003e Rack Chassis Module) provides direct physical\/electrical execution. This heavy-duty structural chassis houses a multi-layer printed circuit board backplane that mechanically guides and electrically connects individual plug-in control modules. The unified backplane distribution network establishes robust signal paths across adjacent modules, eliminating point-to-point wiring loops while securing structural integrity against continuous low-frequency industrial vibrations.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e259B2460BTG2 \/ 512AZSPBPAC-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e430 mm x 480 mm x 580 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive distribution network (Continuous load depends on inserted modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP (Supported via hosted modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade metal chassis with integrated multi-layer PCB backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI Speedtronic Turbine Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Signal Continuity\u003c\/h3\u003e\n\u003cp\u003eThe integrated PCB backplane features parallel trace routing geometries optimized for localized backplane bus communication velocity and signal synchronization limits. Layered copper planes within the board provide continuous electromagnetic shielding and controlled impedance parameters for high-speed serial data exchanges. The 24 VDC power distribution rail utilizes heavy copper traces to minimize localized IR voltage drops across slot positions, suppressing transient noise from module insertion or load switching. The mechanical card guides ensure rigid module alignment with pin-and-socket backplane connectors, maintaining low contact resistance and preventing signal cross-talk during thermal expansion cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the current loading capacity per module slot on this backplane assembly?\u003c\/p\u003e\n\u003cp\u003eA: The backplane copper trace dimensioning supports a nominal continuous load under standard 24 VDC delivery, but total system current draw is strictly governed by the collective power consumption curves of the installed modules and must not exceed the main power supply terminal limits.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 259B2460BTG2 backplane board support direct online hot-swapping of control cards?\u003c\/p\u003e\n\u003cp\u003eA: The backplane connectors incorporate staggered-pin layouts to ground modules prior to logic line activation, but hot-swap execution is entirely dependent on the firmware architecture and safety parameter settings of the specific GE Mark VI control cards being inserted or removed.\u003c\/p\u003e\n\u003cp\u003eQ: How is the metal rack enclosure grounded to prevent floating potentials?\u003c\/p\u003e\n\u003cp\u003eA: The chassis features dual heavy M6 threaded grounding studs on the rear panel structure, which require direct copper braid connection to the main plant instrumentation grounding grid to safely drain stray high-frequency currents.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the chassis into a standard industrial equipment enclosure or cabinet rack, verifying that all four structural mounting bolts are torqued down to prevent mechanical oscillation.\u003c\/li\u003e\n\u003cli\u003eEnsure a minimum of 100 mm of clear workspace above and below the chassis assembly to allow unobstructed ambient convection airflow through the hosted modules.\u003c\/li\u003e\n\u003cli\u003eInspect the female socket pin arrays on the backplane for mechanical distortion, bent contacts, or foreign matter before inserting any active control modules.\u003c\/li\u003e\n\u003cli\u003eVerify the integrity of the incoming 24 VDC power feed cables and check polarity before terminating the wires onto the chassis input terminal block blocks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43869113745507,"sku":"259B2460BTG2 512AZSPBPAC-100","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/401_2c0a3bc7-58c2-4be3-ab65-53e2d866f10c.jpg?v=1764749767"},{"product_id":"ge-is215aepch1f-analog-i-o-expansion-board-new-stock","title":"GE IS215AEPCH1F Analog I\/O Expansion Board | New Stock","description":"\u003ch2\u003eGE Fanuc IS215AEPCH1F Industrial Analog I\/O Expansion Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IS215AEPCH1F\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS215AEPCH\u003c\/strong\u003e Application Engine Processor Control Module, operates as a dedicated hardware component for control logic execution and real-time analog signal processing within GE Mark VIe Control System networks. The module establishes a high-density processing node that interfaces directly with physical actuator control loops, instrumentation transmitter signals, and centralized controller networks. Operating directly on the distributed control network layer, the hardware digitizes analog sensor metrics and drives precise modulation currents to turbine fuel valves, guide vanes, and auxiliary field systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS215AEPCH1F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e300 mm x 210 mm x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal 24 VDC input drive logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeployed I\/O Count\u003c\/td\u003e\n\u003ctd\u003e8 analog inputs, 4 analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetworking Support\u003c\/td\u003e\n\u003ctd\u003eDual-redundant Ethernet, Modbus TCP\/IP, GE proprietary protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Functions\u003c\/td\u003e\n\u003ctd\u003eExecution of localized turbine control logic, I\/O monitoring, and hardware diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulatory Compliance\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Network Determinism\u003c\/h3\u003e\n\u003cp\u003eThe processing engine embedded within the IS215AEPCH1F optimizes backplane bus communication velocity across its local bus interfaces to execute multi-variable control loops inside fixed microsecond task slices. The communication layer integrates directly into Profinet \/ EtherNet\/IP deterministic networks and GE proprietary IONet fabrics, permitting jitter-free transmission of critical process variables and system diagnostic words. High-performance galvanic isolation fields wrap all internal analog-to-digital converter circuits, maintaining standard firmware flash compatibility and ensuring uniform loop computation intervals under severe electromagnetic switching transients.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IS215AEPCH1F module be extracted from the backplane assembly during live turbine operation?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal logic bus does not permit hot-swapping while energized. Disconnecting the module during active operation breaks the high-speed communication link, interrupts the critical analog control loops, and causes an immediate fail-safe turbine trip across the Mark VIe platform.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle calibration values and local firmware integrity during hardware re-flashing?\u003c\/p\u003e\n\u003cp\u003eA: The board features a non-volatile memory matrix controlled by a strict firmware flash compatibility engine. During runtime configuration or firmware updates, new files are staged and validated via block checksum calculations in an isolated sector prior to deployment, preventing logic corruption and keeping pre-configured transmitter calibration maps fully intact.\u003c\/p\u003e\n\u003cp\u003eQ: What mechanisms protect the 8 analog inputs from field-side electrical surges?\u003c\/p\u003e\n\u003cp\u003eA: Every analog channel is built with individual over-voltage clamp networks and decoupling capacitors that safely divert high-energy transients to the chassis earth ground, preventing electrical damage from migrating into the core processor circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSlide the board assembly into its designated chassis card guide slot, applying even mechanical force until the high-density edge connectors seat fully into the backplane receiver block.\u003c\/li\u003e\n\u003cli\u003eTerminate all field analog input and output loops using twisted, individually shielded pairs, and ground the drain wires exclusively at the dedicated cabinet earth bus bar.\u003c\/li\u003e\n\u003cli\u003eSeparate the incoming low-voltage DC power wires and network communication links from high-current motor starters and AC ignition transformer lines by a minimum of 300 mm inside the enclosure.\u003c\/li\u003e\n\u003cli\u003eVerify that cabinet fan assemblies are operating properly to provide continuous forced-air cross-flow across the surface components throughout the full -40 to 70 deg C thermal window.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43869318283363,"sku":"IS215AEPCH1F","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/311_ff29635a-a6ef-4b2d-8d91-224b1cc01d06.jpg?v=1764752092"},{"product_id":"ge-fanuc-ic695alg728-pacsystems-rx3i-8-channel-ao-module","title":"GE Fanuc IC695ALG728 PACSystems RX3i 8-Channel AO Module","description":"\u003ch2\u003eGE Fanuc IC695ALG728 PACSystems RX3i Series\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-accuracy voltage and current loop execution in PACSystems RX3i platforms, the \u003cstrong\u003eGE Fanuc IC695ALG728\u003c\/strong\u003e (\u003cstrong\u003eIC695ALG728\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695ALG728\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e142 mm x 100 mm x 34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e500 mA @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 analog output channels (non-isolated, shared common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Types\u003c\/td\u003e\n\u003ctd\u003e0 to 10 VDC, 4 to 20 mA (with superimposed HART)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit Digital-to-Analog conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL, CE, ATEX Zone 2, CSA, Marine (ABS, BV, DNV, GL, KRS, LR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Drive Technical Attributes\u003c\/h3\u003e\n\u003cp\u003eThe architecture links multiple analog loops directly to the RX3i chassis while managing data alignment alongside preset backplane bus communication velocity parameters. To ensure uninterrupted command execution during heavy multi-channel scaling and dense I\/O density scaling profiles, the digital processing engine syncs field-side variables with current firmware flash compatibility versions. The integrated circuitry enables real-time device diagnostic transmission across deterministic networks, supporting HART digital messaging over the analog current path without altering standard output loop response.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module prevent register data loss during standard firmware flash compatibility synchronization?\u003c\/p\u003e\n\u003cp\u003eA: System engineers must fully halt the active controller execution path and disconnect active field wiring blocks before starting a firmware update sequence to avoid corruption across the backplane bus communication velocity rails.\u003c\/p\u003e\n\u003cp\u003eQ: Is online hot-swap module replacement supported for the IC695ALG728 within an active RX3i rack layout?\u003c\/p\u003e\n\u003cp\u003eA: While the PACSystems RX3i backplane permits hot-swapping under specific software configurations, field safety steps require isolating external 4 to 20 mA loops prior to extraction to prevent high-current transients across the shared common reference.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Insertion and Connector Engagement:\u003c\/strong\u003e Slide the module firmly into the targeted RX3i slot assignment. Ensure the upper and lower plastic retaining clips engage fully with the chassis perimeter rail to preserve proper structural balance under vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Loop Shield Continuity:\u003c\/strong\u003e Terminate all external twisted-pair signal loop shields at the designated cabinet grounding block. Avoid tying shields to the module common terminals to limit noise ingress into the 16-bit D\/A converters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Separation and Routing:\u003c\/strong\u003e Route the 8-channel analog signal lines through isolated low-voltage wire guides, maintaining physical distance from parallel high-voltage AC motor lines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43872403882083,"sku":"IC695ALG728","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/380_984ab237-1103-4229-b682-e1d4b2e64c7e.jpg?v=1764900845"},{"product_id":"ic695rmx128-ab-ge-fanuc-hot-standby-rmx-module","title":"IC695RMX128-AB GE Fanuc Hot Standby RMX Module","description":"\u003ch2\u003eGE Fanuc IC695RMX128-AB PACSystems RX3i Series\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC695RMX128-AB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC695RMX128\u003c\/strong\u003e Redundant Memory Xchange Module, operates as a dedicated hardware component for high-speed deterministic data sharing and hot-standby CPU synchronization within PACSystems RX3i platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695RMX128-AB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard RX3i rack-mounted module profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMaintained via PACSystems RX3i backplane rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e128 MB reflective memory allocation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Topology\u003c\/td\u003e\n\u003ctd\u003eSupports up to 256 nodes (compatible with 5565 family)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interface\u003c\/td\u003e\n\u003ctd\u003eFiber optic transceiver ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLatency\u003c\/td\u003e\n\u003ctd\u003eMicrosecond-level tracking latency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Drive Technical Attributes\u003c\/h3\u003e\n\u003cp\u003eThe reflective memory architecture bypasses standard protocol layers to sync registers directly over fiber paths while maintaining strict alignment with backplane bus communication velocity parameters. To eliminate execution delays during high-frequency data copying and heavy system node scaling, the internal arbitration engine handles data transfers matching specific firmware flash compatibility baselines. The underlying transceiver matrix functions on deterministic networks, passing memory images with microsecond-level delay profiles to prevent state split-brain faults across hot-standby CPU loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the IC695RMX128-AB module maintain full data integrity during sudden firmware flash compatibility re-alignments?\u003c\/p\u003e\n\u003cp\u003eA: Updates must be performed during scheduled plant shutdowns while the active hot-standby link is safe, preventing synchronization failures across the backplane bus communication velocity channels.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swap module replacement supported for this hardware module within an active RX3i rack infrastructure?\u003c\/p\u003e\n\u003cp\u003eA: While the RX3i chassis supports live module placement, field rules mandate completely disconnecting the fiber optic cables prior to module extraction to prevent transient optical errors from disrupting the backup node.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber Optic Cable Bending Radius:\u003c\/strong\u003e Install multi-mode fiber connections into the dedicated transceiver ports. Keep the fiber bend radii within standard specifications to ensure structural balance and prevent optical signal loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Seating Verification:\u003c\/strong\u003e Insert the module firmly into the planned RX3i slot assignment. Engage the top and bottom grounding clips fully against the chassis rail to limit electrical noise interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNode ID Layout Control:\u003c\/strong\u003e Program the distinct node address using the system configuration software utility panel, verifying that no duplicate node numbers exist across the 256-node reflective loop network.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43872414466147,"sku":"IC695RMX128-AB","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/381_068b986a-d137-48d3-a33d-1c743c4378d5.jpg?v=1764901015"},{"product_id":"ge-fanuc-ic754vsi06mtd-lh-quickpanel-view-operator-interface-terminal","title":"GE Fanuc IC754VSI06MTD-LH QuickPanel View Operator Interface Terminal","description":"\u003ch2\u003eGE Fanuc IC754VSI06MTD-LH QuickPanel View HMI\u003c\/h2\u003e\n\u003cp\u003eConfigured for real-time process visualization and operator command execution in distributed control networks, the \u003cstrong\u003eGE Fanuc IC754VSI06MTD-LH\u003c\/strong\u003e (\u003cstrong\u003eIC754VSI06MTD\u003c\/strong\u003e HMI Terminal) provides direct physical\/electrical execution. This operator interface decodes binary runtime logic into a 320 x 240 pixel monochrome matrix via a resistive touchscreen interface. The unit establishes direct master\/slave telemetry links with programmable logic controllers using integrated serial and Ethernet hardware layers, bypassing external conversion bridges to execute data register read\/write sequences.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC754VSI06MTD-LH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e200 mm x 150 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0-50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e6-inch Monochrome Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e320 x 240 Pixels (QVGA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eLong-life LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Technology\u003c\/td\u003e\n\u003ctd\u003eResistive (Finger or Stylus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interfaces\u003c\/td\u003e\n\u003ctd\u003eRS-232 \/ RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eEthernet Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Industrial Network Interfacing\u003c\/h3\u003e\n\u003cp\u003eThe HMI architecture interfaces directly with the GE Fanuc backplane bus network via its onboard communication controllers. The embedded Ethernet interface establishes dedicated TCP\/IP application layers to guarantee deterministic network data exchange rates with upstream controllers, preventing telemetry dropouts during high bus saturation. The integrated serial sub-circuits support selectable RS-232 and RS-485 signaling modes, enabling peer-to-peer serial routing without auxiliary line drivers. Furthermore, the internal processor architecture maintains firmware flash compatibility to support fieldbus interface expansion card modules, expanding data registers mapping capacity while preserving synchronized scan cycles across local and remote I\/O density scaling frameworks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the grounding constraints for the RS-485 serial communication port?\u003c\/p\u003e\n\u003cp\u003eA: The RS-485 interface requires a common signal ground potential across all networked nodes. Installers must connect the cable shield to a low-impedance functional earth ground at a single node to eliminate electrical ground loops and prevent serial data corruption from high-frequency common-mode noise.\u003c\/p\u003e\n\u003cp\u003eQ: How does the touchscreen assembly respond to severe EMI or localized electrical noise?\u003c\/p\u003e\n\u003cp\u003eA: The analog resistive touchscreen overlay isolates physical touch pressures mechanically from internal logic circuits. However, to prevent unintended input registration or transient glitching caused by localized electromagnetic fields, you must route all 24 VDC power and communication cables in separate grounded steel conduits away from AC motor drives and heavy switchgear.\u003c\/p\u003e\n\u003cp\u003eQ: Can the application firmware be flashed directly via the integrated Ethernet interface?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the runtime environment permits firmware flash updates and application code downloading through the Ethernet port using a direct peer-to-peer TCP\/IP connection. The internal flash memory retains the core bootloader sequence to ensure unit recovery in the event of a power interruption during the update process.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Cutout and Gasket Integrity:\u003c\/strong\u003e The panel-mount installation requires a clean cutout matching the exact physical dimensions of the chassis. Ensure the continuous rubber sealing gasket seats uniformly flat against the enclosure surface to maintain ingress protection ratings and prevent dust or moisture migration into the internal electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Power Input Routing:\u003c\/strong\u003e Connect the incoming 24 VDC supply line using heavy-gauge conductors to minimize voltage drop. Install a dedicated 1 A fast-acting fuse or miniature circuit breaker upstream on the positive DC rail to protect the internal power supply components from overcurrent conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit and Shielding Separation:\u003c\/strong\u003e Run all serial communication and Ethernet cables inside separate, dedicated metal conduits. Maintain a minimum clearance of 300 mm from all high-voltage AC power wiring or variable frequency drive cables to eliminate inductive cross-talk and signal distortion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Convection Clearances:\u003c\/strong\u003e Allow a minimum passive clearance of 50 mm around all sides of the HMI housing inside the control panel enclosure. Do not block the integrated ventilation slots, as obstruction will impede the natural thermal heat sink dissipation profile and can cause localized component overheating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43872420495459,"sku":"IC754VSI06MTD-LH","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/382_b313ebdf-2823-46f9-807f-4419dd8a7069.jpg?v=1764901534"},{"product_id":"ge-vmic-pci-5565-010-deterministic-real-time-communication-interface","title":"GE VMIC PCI-5565-010 Deterministic Real-Time Communication Interface","description":"\u003ch2\u003eGE PCI-5565‑010 Reflective Memory Interface\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE PCI-5565‑010\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePCI-5565\u003c\/strong\u003e Reflective Memory Interface, operates as a dedicated hardware component for deterministic, real-time data sharing within distributed control and simulation networks. The card features a dedicated 128 MB onboard SDRAM array that duplicates incoming memory packets across a fiber-optic network at speeds up to 2.125 Gbps. By removing standard networking layer overhead, the hardware allows multiple independent nodes to execute unified read\/write routines to a synchronized shared memory space.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePCI-5565‑010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (VMIC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PCI Card Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0-60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 1.8 A (Typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard Memory\u003c\/td\u003e\n\u003ctd\u003e128 MB SDRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003ePCI, 32-bit, 33 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSustained Transfer Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 132 MB\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Transmission Rate\u003c\/td\u003e\n\u003ctd\u003e2.125 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNode-to-Node Latency\u003c\/td\u003e\n\u003ctd\u003e~1 microsecond\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Node Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 256 Nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Optic Compatibility\u003c\/td\u003e\n\u003ctd\u003eSingle-mode (10 km max) \/ Multi-mode (300 m max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Data Replication and Firmware Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe architecture executes data transmission via a dedicated serial fiber-optic interface, completely isolated from host operating system dependencies. When a local CPU executes a write command to the 128 MB SDRAM array, the onboard logic immediately packages the data into packets ranging from 4 to 64 bytes and transmits it into the ring or star topology network. The integrated networking controllers handle all packet formatting and routing independently, ensuring that I\/O density scaling profiles remain decoupled from local CPU processing loads. Furthermore, the card maintains full firmware flash compatibility across Windows, Linux, and VxWorks platforms to secure consistent backplane bus communication velocity under varying network load demands.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the mechanical and electrical impact of adding a Reflective Memory Hub into the network loop?\u003c\/p\u003e\n\u003cp\u003eA: Integrating an external Reflective Memory Hub converts a standard physical ring topology into a logical star configuration. The hub adds a predictable propagation delay but provides port isolation and automatic bypass mechanics if an individual node loses electrical power, maintaining network ring integrity without system-wide dropouts.\u003c\/p\u003e\n\u003cp\u003eQ: How does the packet size variation affect the actual data transfer throughput of the module?\u003c\/p\u003e\n\u003cp\u003eA: The onboard transmission logic optimizes data throughput based on data density. Small 4-byte packets incur higher relative protocol overhead, yielding a transfer rate of 43 MB\/s, whereas larger 64-byte blocks leverage full network bandwidth to achieve a maximum transfer velocity of 170 MB\/s while maintaining the same node-to-node latency.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical Interface Contamination Control:\u003c\/strong\u003e Clean all fiber-optic ferrules with a lint-free wipe before seating them into the onboard transceivers. Particulate buildup on the 2.125 Gbps transmitter or receiver interfaces can cause packet degradation, leading to continuous hardware CRC error flags.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber-Optic Bend Radius Limits:\u003c\/strong\u003e Do not allow the physical single-mode or multi-mode fiber patch cables to drop below a minimum bend radius of 30 mm. Exceeding this mechanical limit creates micro-bends that scatter the optical signal, reducing transmission distances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCI Card Slot Seating and Grounding:\u003c\/strong\u003e Power down the host chassis completely before inserting the board into a 32-bit PCI slot. Fasten the metal faceplate retention screw firmly to the computer chassis frame to ensure a low-impedance ground path for transient shielding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Convection Requirements:\u003c\/strong\u003e Ensure neighboring expansion slots do not block ambient air passage across the onboard memory and transceiver logic chips. The board requires unrestricted convection currents to stabilize the 128 MB SDRAM during sustained full-load operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43872510574691,"sku":"VMIC PCI-5565-010","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/385_fc032058-18ae-4ed1-99fb-be0221a2bf1e.jpg?v=1764902461"},{"product_id":"ge-pacsystems-rx3i-ic695alg106-da-isolated-16-bit-a-d-converter-card","title":"GE PACSystems RX3i IC695ALG106-DA Isolated 16-Bit A\/D Converter Card","description":"\u003ch2\u003eGE Fanuc IC695ALG106‑DA Isolated Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for precise voltage and current signal acquisition in distributed automation environments, the \u003cstrong\u003eGE Fanuc IC695ALG106‑DA\u003c\/strong\u003e (\u003cstrong\u003eIC695ALG106\u003c\/strong\u003e Isolated Analog Input Module) provides direct physical\/electrical execution. The hardware samples six isolated inputs using a 16-bit analog-to-digital converter, mapping unconditioned electrical transients straight into standardized controller data registries. By executing physical signal conditioning entirely on the localized terminal block layer, the module stabilizes internal loop data values before transfer to the controller.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695ALG106‑DA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e700 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PACSystems RX3i Single-Slot Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0-60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eRack Powered via PACSystems RX3i Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e6 Isolated Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA, \\pm 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e\\pm 10 V, 0-10 V, \\pm 5 V, 0-5 V, 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit Analog-to-Digital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Routing and High-Speed Memory Mapping\u003c\/h3\u003e\n\u003cp\u003eThe card manages localized I\/O density scaling through structured high-speed memory scanning loops. Onboard logic circuits parse incoming analog registers independently from the central processor, verifying full firmware flash compatibility to protect systemic update pathways under full backplane load. This automated polling design integrates with Profinet \/ EtherNet\/IP deterministic networks, ensuring constant backplane bus communication velocity while preventing loop processing dropouts during multi-channel diagnostics execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the internal hardware layer handle channel-to-channel isolation limits under steady-state overvoltage faults?\u003c\/p\u003e\n\u003cp\u003eA: The card incorporates physical optocouplers and magnetic transformers to establish channel-to-channel isolation boundaries across all six inputs. If a single field wire experiences a surge or localized ground potential shift within the specified tolerance limits, the isolation path confines the fault to that specific terminal loop, preventing crosstalk and shielding the host backplane from damage.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 16-bit analog-to-digital conversion configuration be modified for individual channels without altering adjacent inputs?\u003c\/p\u003e\n\u003cp\u003eA: Yes, each input channel contains separate configuration data paths. Using the engineering station, installers write configuration parameters to define signal parameters (such as switching from 4-20 mA to 0-10 V) on an isolated basis, allowing variable input sensors to reside together on a single single-slot card slot module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block Mechanical Seating:\u003c\/strong\u003e Select and secure one compatible terminal assembly (IC694TBB032, IC694TBB132, IC694TBS032, or IC694TBS132). Press the module firmly onto the PACSystems RX3i backplane connector tracks, ensuring that the alignment pins are straight and the retention hooks click completely into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Matrix Configuration:\u003c\/strong\u003e Route all analog input wiring using twisted-pair shielded cables. Terminate the bare braided shield layer directly to the grounding bar located at the base of the local control cubicle; do not connect both ends of the shield to eliminate ground loop current generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit and Signal Routing Boundaries:\u003c\/strong\u003e Keep all low-potential 4-20 mA and low-voltage lines inside dedicated grounded steel conduits. Maintain a minimum physical distance of 300 mm from high-current AC motor leads or industrial variable speed drives to mitigate inductive noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvection Cooling and Thermal Clearances:\u003c\/strong\u003e Verify that top and bottom ventilation paths on the host rack chassis remain entirely unblocked. The card dissipates heat through standard vertical convection, and keeping clearances open prevents component drift outside the 0-60 deg C operational limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43872604782691,"sku":"IC695ALG106-DA","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/390_34cae5f4-06f1-4f82-a42d-64d1d53149aa.jpg?v=1764905096"},{"product_id":"ge-fanuc-ic695alg412-pacsystems-rx3i-analog-input-modules","title":"GE Fanuc IC695ALG412 PACSystems RX3i Analog Input Modules","description":"\u003ch2\u003eGE Fanuc IC695ALG412 PACSystems RX3i Analog Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC695ALG412\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC695ALG412\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for multi-sensor signal conditioning and digitizing within PACSystems RX3i platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695ALG412\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e350 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e115 x 100 x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e425 mA @ 5 VDC, 400 mA @ 3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e12 isolated differential channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Sensor Types\u003c\/td\u003e\n\u003ctd\u003eThermocouples (J, K, T, E, R, S, B, N, C), Millivolt (+\/-150 mV, +\/-50 mV), Direct Strain Gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Resolution\u003c\/td\u003e\n\u003ctd\u003e32-bit IEEE floating point or 16-bit integer inside 32-bit field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Architecture\u003c\/td\u003e\n\u003ctd\u003eSigma-Delta A\/D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Barrier\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous (channel-to-channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eGreater than or equal to 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IC695ALG412 optimizes control system architecture by executing dense analog data collection across 12 isolated channels within a single-slot footprint. The underlying platform handles high I\/O density scaling via a Sigma-Delta A\/D converter, mapping input parameters directly into processor memory with configurable conversion rates from 15 ms to 120 ms. Maintaining strict firmware flash compatibility across backplane bus communication structures allows the host controller to perform synchronous variable reads without introducing phase shift errors during parallel execution loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the hardware architecture isolate the separate field sensor inputs? A: The module applies physical galvanic isolation rated at 250 VAC continuous between individual differential channels, suppressing potential ground loop degradation and maintaining common-mode rejection limits.\u003c\/p\u003e\n\u003cp\u003eQ: What specific hardware-level diagnostic routines run during operation? A: The onboard circuitry tracks live signal metrics to detect open\/short circuits, evaluate high\/low thresholds, and trigger positive or negative rate-of-change alarms based on configured limits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDe-energize the entire PACSystems RX3i backplane rack before inserting or removing the hardware from its mechanical slot.\u003c\/li\u003e\n\u003cli\u003eSlide the unit vertically down the chassis rails until the rear connectors mate with the backplane bus, then torque the module securing screws into the rack base.\u003c\/li\u003e\n\u003cli\u003eFasten the external field sensor wires to a compatible removable terminal block, routing thermocouple extensions and strain gauge bridge connections inside a separate dedicated low-voltage wire duct.\u003c\/li\u003e\n\u003cli\u003eGround all signal cable braids at one single end on the local enclosure bulkhead ground bar to prevent noise propagation across the high-impedance input instrumentation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43872633618531,"sku":"IC695ALG412","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/70_f6f18bfa-08a7-47dc-b7be-34e95f4eca8d.jpg?v=1764907119"},{"product_id":"ge-fanuc-ic695alg628-pacsystems-rx3i-analog-input-modules","title":"GE Fanuc IC695ALG628 PACSystems RX3i Analog Input Modules","description":"\u003ch2\u003eGE Fanuc IC695ALG628 PACSystems RX3i Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for precise process automation and industrial control in PACSystems RX3i networks, the \u003cstrong\u003eGE Fanuc IC695ALG628\u003c\/strong\u003e (\u003cstrong\u003eIC695ALG628\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695ALG628\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e145 x 140 x 34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e34 mA @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Ranges\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Ranges\u003c\/td\u003e\n\u003ctd\u003e+\/-10 V, 0-10 V, +\/-5 V, 0-5 V, 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eHART protocol enabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL, CE, ATEX, Zone 2, C1D2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IC695ALG628 optimizes data acquisition efficiency by managing 8 distinct analog input loops inside a single-slot RX3i chassis footprint. The module handles high-precision voltage and current conversion loops through a 16-bit resolution engine, enabling tight scaling metrics across diverse industrial transmitter layouts. System integration routines utilize explicit firmware flash compatibility architectures across the RX3i backplane bus to ensure uninterrupted parameter polling, preventing data collision when parallel diagnostic routines extract HART-modulated smart variables alongside primary variables.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the interface maintain isolation across separate transmitter connections?\u003c\/p\u003e\n\u003cp\u003eA: The hardware employs dedicated channel-to-channel isolation architecture across all 8 inputs. This internal electrical barrier blocks ground loop propagation and attenuates common-mode electrical noise across adjacent field loops.\u003c\/p\u003e\n\u003cp\u003eQ: What specific power demands does the module impose on the RX3i rack power supply?\u003c\/p\u003e\n\u003cp\u003eA: The module draws its operating power directly from the active RX3i backplane bus, demanding a low current load of approximately 34 mA at 5 VDC during standard signal execution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDe-energize the central PACSystems RX3i rack and all auxiliary external instrumentation loops before mounting or extracting the module.\u003c\/li\u003e\n\u003cli\u003eInsert the unit into the chosen backplane slot along the molded mechanical alignment tracks, exerting uniform force until the rear bus connector seats tightly.\u003c\/li\u003e\n\u003cli\u003eConnect all field instruments using multi-conductor twisted pairs with individual shields, grounding the copper shields exclusively at the designated enclosure marshaling ground strip.\u003c\/li\u003e\n\u003cli\u003eSeparate low-voltage analog instrumentation wiring (4-20 mA \/ 0-10 V) from high-power AC terminal conductors within the wire routing trays to mitigate inductive signal distortion.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43872699547747,"sku":"IC695ALG628","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/397._d41f9f61-0460-4a86-9978-1436ee4ac6be.jpg?v=1764913397"},{"product_id":"8710-ca-04-ge-pac8000-four-module-backplane-carrier","title":"8710-CA-04 GE PAC8000 Four-Module Backplane Carrier","description":"\u003ch2\u003eGE 8710-CA-04 PAC8000 Four-Module Backplane Carrier\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE 8710-CA-04\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8710-CA-04\u003c\/strong\u003e Four-Module Backplane Carrier, operates as a dedicated hardware component for mechanical and electrical module interfacing within PAC8000 distributed control platforms. This hardware assembly establishes the primary bus links and field power routing infrastructure required to sustain multi-channel data paths across node structures. By standardizing physical terminal connections and executing localized signal tracking, the carrier manages continuous power and bus logic distribution directly to mounted active components.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8710-CA-04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PAC8000 carrier footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C (Standard industrial baseline)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive distribution \/ Bussed Field Power interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 4 PAC8000 I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddressing Range\u003c\/td\u003e\n\u003ctd\u003e64-slot addressing standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Distribution\u003c\/td\u003e\n\u003ctd\u003eBussed Field Power (BFP) system feeding adjacent slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Options\u003c\/td\u003e\n\u003ctd\u003eStandard T-section DIN-rail, G-section DIN-rail, or flat-surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination\u003c\/td\u003e\n\u003ctd\u003eSnap-on field terminals with integrated shield tracks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Security\u003c\/td\u003e\n\u003ctd\u003eIntegrated mechanical coding key matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Node Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe 8710-CA-04 integrates into large node layouts by executing specific I\/O density scaling protocols over an internal serial data layer. The hardware structure implements a 64-slot addressing design, which requires isolation from legacy 32-slot backplane equipment to prevent data collision and frame timing errors during scan cycles. Bus paths routed through the multi-layer printed circuit plane enforce rigid transmission velocities, allowing synchronized clock cycles between adjacent modules. To preserve signal integrity across high-density configurations, the carrier pairs structural terminal blocks with built-in grounding rails for cable screens, suppressing stray high-frequency electromagnetic interference before it reaches the active backplane data lines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the specific configuration rules regarding mixed-mode slot addressing when using the 8710-CA-04 carrier?\u003c\/p\u003e\n\u003cp\u003eA: The 8710-CA-04 mandates 64-slot addressing logic throughout the complete electrical node segment. It is prohibited to link this hardware concurrently with older 32-slot addressing carriers on the same local bus segment, as mixing configurations disables the backplane address line mapping and prevents the node controller from resolving peripheral slot positions.\u003c\/p\u003e\n\u003cp\u003eQ: How is the field power circuit isolated and allocated across the four module positions?\u003c\/p\u003e\n\u003cp\u003eA: Electrical distribution occurs through dedicated Bussed Field Power (BFP) circuits embedded within the backplane trace matrix. Each independent BFP injection block distributes field operating current to a pair of two adjacent slots, minimizing the physical field supply connection points while preserving localized electrical separation during channel maintenance operations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Alignment and Continuity:\u003c\/strong\u003e Mount the carrier directly onto a verified, unpainted metal T-section or G-section DIN-rail. Ensure the end-to-end alignment locks firmly with adjoining carriers to maintain low-resistance backplane bus plug-in continuity across the entire node backplane assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Keying Alignment:\u003c\/strong\u003e Verify that the mechanical alignment keys located on the face of the carrier match the hardware profile coding of the specific PAC8000 I\/O module to be inserted, preventing physical insertion errors and pin damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Termination Infrastructure:\u003c\/strong\u003e Connect all incoming field instrument cable screens and shields directly to the snap-on field terminal grounding bars. Maintain appropriate distance separating field signal cables from high-voltage AC motor conductors within the control panel ducting to prevent signal cross-talk.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43872744865891,"sku":"8710-CA-04","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/403_1233bf1a-d602-4e9f-a78a-6ccd479a4a24.jpg?v=1764915115"},{"product_id":"ic695alg616-da-ge-rx3i-24-bit-16-channel-analog-input-card","title":"IC695ALG616-DA GE RX3i 24-Bit 16-Channel Analog Input Card","description":"\u003ch2\u003eGE IC695ALG616-DA PACSystems RX3i Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IC695ALG616-DA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC695ALG616\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for multi-channel process variable data acquisition within PACSystems RX3i platforms. The card interfaces directly with raw industrial field signals, routing either 16 single-ended or 8 differential analog circuits into the central computing framework. The module executes signal sampling through an integrated 24-bit analog-to-digital converter core, which translates variable voltage and current loops into numerical register values for real-time calculation by the host controller.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695ALG616-DA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE \/ Emerson Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e14.5 x 14.0 x 3.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e34 mA @ 5 VDC typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 single-ended or 8 differential (Software-configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA, +\/- 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e+\/- 10 V, 0-10 V, +\/- 5 V, 0-5 V, 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADC Resolution\u003c\/td\u003e\n\u003ctd\u003e24-bit analog-to-digital conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Isolation\u003c\/td\u003e\n\u003ctd\u003eNon-isolated input design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5-95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling and Backplane Bus Communication Velocity\u003c\/h3\u003e\n\u003cp\u003eThe IC695ALG616-DA facilitates high-density scaling across the PACSystems local backplane by optimizing multi-channel mapping within a single rack slot footprint. To preserve measurement synchronization, the on-board conversion hardware coordinates data package arrays to match the backplane bus communication velocity licenses of the RX3i chassis. The system executes channel filtering and gain calibration through proprietary logic that features absolute firmware flash compatibility with contemporary CPU modules. This high-speed pipeline translates field values instantly into standard memory words, preventing phase errors during sudden industrial process loop step-changes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the non-isolated channel architecture of the IC695ALG616-DA affect common-mode voltage limits?\u003c\/p\u003e\n\u003cp\u003eA: Because the module utilizes a non-isolated input structure, all field signaling return lines share a common electrical reference point on the board assembly. Personnel must ensure that the voltage differential between adjacent channels remains within technical reference parameters to avoid signal saturation or thermal failure of the input matrix.\u003c\/p\u003e\n\u003cp\u003eQ: What are the restrictions regarding live insertion or hot-swapping the IC695ALG616-DA within an active RX3i system?\u003c\/p\u003e\n\u003cp\u003eA: The PACSystems RX3i backplane platform permits hot-swapping under exact electrical guidelines. The module can be extracted or replaced while backplane power is active, provided that the field wiring terminal block is disconnected first to prevent ungrounded current surges from interrupting neighboring I\/O communications.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion Mechanics:\u003c\/strong\u003e Slide the circuit card assembly smoothly into the designated chassis slot until the integrated rear connectors seat completely into the active backplane. Secure the mechanical module latches to ensure solid retention and electrical grounding continuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Line Shielding:\u003c\/strong\u003e Install twisted-shielded pair conductors for all analog current and voltage loops. Terminate the individual cable drain wires directly to the external chassis grounding bar, keeping the unshielded wire exposure minimal near the terminal screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Separation Routing:\u003c\/strong\u003e Maintain physical separation between the low-voltage analog input signal lines and high-voltage AC electrical distribution runs within the panel enclosure to prevent inductive noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43872754892899,"sku":"IC695ALG616-DA","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/170_fb9d1c42-d1dd-467e-8bae-0561469c1c2f.jpg?v=1764916637"},{"product_id":"ic695pns001-abag-ge-emerson-pacsystems-rx3i-profinet-scanner","title":"IC695PNS001-ABAG GE Emerson PACSystems RX3i PROFINET Scanner","description":"\u003ch2\u003eGE Emerson IC695PNS001-ABAG PACSystems RX3i PROFINET Controller Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for direct physical\/electrical execution in PACSystems RX3i platforms, the \u003cstrong\u003eGE Emerson IC695PNS001-ABAG\u003c\/strong\u003e (\u003cstrong\u003eIC695PNS001-ABAG\u003c\/strong\u003e PROFINET Scanner Module) operates as a dedicated hardware component for distributed device interface management within PROFINET networks. The hardware module coordinates cyclic data communication arrays across external network nodes, mapping external parameter words directly into the host memory structure. Operating two physical RJ-45 media interfaces, the component handles real-time protocol framing and synchronization routines to maintain deterministic data patterns across active remote sub-racks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695PNS001-ABAG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE \/ Emerson Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard RX3i single-slot rack-mount dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7 W from RX3i backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003ePROFINET IO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Device Limit\u003c\/td\u003e\n\u003ctd\u003eUp to 128 PROFINET I\/O devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurable Update Rates\u003c\/td\u003e\n\u003ctd\u003e1 ms to 512 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Interface Ports\u003c\/td\u003e\n\u003ctd\u003e2 x RJ-45 Ethernet ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Speeds\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps, full-duplex, auto-negotiation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Topologies\u003c\/td\u003e\n\u003ctd\u003eStar, line, ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Diagnostics\u003c\/td\u003e\n\u003ctd\u003eLED status array \/ Integrated configuration web server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5-95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC695PNS001-ABAG structures network traffic inside high-capacity Profinet \/ EtherNet\/IP deterministic networks by executing strict packet processing timelines over its dual switched interfaces. The module provides substantial I\/O density scaling options, allowing up to 128 distributed remote nodes to run cyclic communication links concurrently on a single master loop. This deterministic execution profile matches the high-speed logic lines of the hosting chassis, resolving data frames with fixed cyclic update loops as low as 1 ms. The on-board communication logic isolates the core CPU from high-volume network noise during continuous high-density I\/O packet transfers, keeping peripheral error logs independent of the main controller task timing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the IC695PNS001-ABAG module maintain data stability during an open-loop fault inside a network ring topology?\u003c\/p\u003e\n\u003cp\u003eA: The module supports media redundancy protocols across its dual switched RJ-45 ports. When a cable fracture occurs inside a ring structure, the on-board logic re-routes the real-time communication frames within the specified deterministic timeout boundary, keeping all 128 remote I\/O devices active and transferring fault diagnostics to the RX3i CPU.\u003c\/p\u003e\n\u003cp\u003eQ: What are the primary constraints regarding the live insertion or removal of this communication scanner?\u003c\/p\u003e\n\u003cp\u003eA: Although the PACSystems RX3i platform incorporates specific backplane attributes allowing live insertion, uncoupling this module while network transactions are active will break all remote I\/O scans instantly. Disconnecting the card under load disrupts deterministic network structures, stops frame verification, and will generate immediate I\/O loss faults inside the master processor.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Engagement and Mechanical Grounding:\u003c\/strong\u003e Align the card accurately with the designated single-slot backplane tracks of the RX3i chassis. Slide the card inward firmly until the rear pins hook securely into the backplane, and engage the mechanical latches to establish an effective ground bond.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Shielding and Media Segregation:\u003c\/strong\u003e Deploy double-shielded, industrial-grade Cat5e or Cat6 twisted-pair cables for all network connections. Route the communication lines completely outside panel channels carrying variable frequency drive outputs or high-amperage power circuits to eliminate inductive cross-talk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort Strain Relief Setup:\u003c\/strong\u003e Secure all network cables to separate structural strain-relief mounts within the electrical cabinet. This configuration prevents mechanical vibration from putting continuous tension on the RJ-45 physical connections, protecting the port assemblies from intermittent packet dropouts.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43872767115363,"sku":"IC695PNS001-ABAG","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/408_60e4b8ae-5db1-4235-b9fc-3e93358f4bba.jpg?v=1764916961"}],"url":"https:\/\/www.autocontrolglobal.com\/collections\/ge-fanuc-pacsystems-rx3i-controllers.oembed?page=5","provider":"AutoControl Global","version":"1.0","type":"link"}