{"title":"Yokogawa CPU Module","description":"\u003cp\u003eYokogawa's CPU modules, also known as Central Processing Units (CPUs), serve as the brain of Yokogawa's industrial automation systems. They are responsible for processing data received from input modules, executing control programs, and sending control signals to output modules. Essentially, they handle the entire control logic of the automation process.\u003c\/p\u003e\n\u003ch3\u003eExamples of Yokogawa CPU Modules\u003c\/h3\u003e\n\u003cp\u003eYokogawa offers a variety of CPU modules across different control system series, each designed to meet specific application requirements and offering varying degrees of complexity and functionality. Some examples include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCENTUM VP R3000 CPU Module\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCENTUM VP F1000 CPU Module\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCENTUM CS1000 CPU Module\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCENTUM NX10 CPU Module\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFASTA 2000 CPU Module\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese modules belong to different Yokogawa control system series such as CENTUM VP, CENTUM CS, CENTUM NX, and FASTA. Each series caters to distinct industrial automation needs, providing solutions tailored to different scales of operations and application complexities.\u003c\/p\u003e\n\u003c!----\u003e","products":[{"product_id":"cp461-50-yokogawa-processor-module","title":"CP461-50 | Yokogawa | Processor Module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe YOKOGAWA CP461-50 is a high-performance processor module for use with the Yokogawa CENTUM VP distributed control system (DCS). It is a compact and modular module that is designed for easy installation and maintenance. The CP461-50 is powered by a high-performance CPU that allows it to handle complex control algorithms and large amounts of data in real time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer :\u003c\/strong\u003e Yokogawa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct No. :\u003c\/strong\u003e CP461-50\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type :\u003c\/strong\u003e Processor Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCP461 :\u003c\/strong\u003e Processor Module (for AFV300\/AFV400)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuffix Codes :\u003c\/strong\u003e 5 = Standard type with no explosion protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuffix Codes :\u003c\/strong\u003e 0 = Basic type\u003c\/li\u003e\n\u003cli\u003e2 modules for dual-redundant configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Module (Non-standard component.) :\u003c\/strong\u003e Max. 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions ( D x W x H ) : \u003c\/strong\u003e15.2 cm x 5.1 cm x 20.3 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight :\u003c\/strong\u003e 0.7 Kg\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight : \u003c\/strong\u003e2 Kg\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42156934955107,"sku":"CP461-50","price":530.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/CP461_3.jpg?v=1741072892"},{"product_id":"yokogawa-cp333d-processor-module","title":"Yokogawa CP333D Processor Module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CP333D is a Processor Module that plays a pivotal role within the Centum CS distributed control system (DCS), serving as its computational nucleus. It is responsible for executing control logic, processing I\/O signals, and managing communication with other system components. The module is available in both new and used conditions and has been tested with a 2-year warranty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Type\u003c\/strong\u003e: AS S9951DA-002\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStyle\u003c\/strong\u003e: S323\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication\u003c\/strong\u003e: Used in Yokogawa Centum CS - Centum VP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 8.0\" x 2.0\" x 10.0\" (20.3 cm x 5.1 cm x 25.4 cm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 2 lbs 4.0 oz (1.0 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e: 90 to 264 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e: 3.3 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current Range\u003c\/strong\u003e: 0 to 3 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: 92%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Ripple and Noise\u003c\/strong\u003e: Less than 2 mVp-p\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42156937773155,"sku":"CP333D","price":510.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/CP333D_2.jpg?v=1741072891"},{"product_id":"yokogawa-scp451-51-central-processor-module","title":"Yokogawa | SCP451-51 | Central Processor Module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe SCP451-51 is a high-performance processor module designed for use in Yokogawa’s ProSafe-RS safety instrumented systems (SIS). It provides essential control and monitoring functions for safety-critical processes in industries such as chemical, oil and gas, and power. The module is available in both new and used conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication\u003c\/strong\u003e: Used in Yokogawa ProSafe-RS safety instrumented systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed Processor\u003c\/strong\u003e: Features a high-speed, 32-bit processor for real-time processing of safety-critical tasks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Tasking Capability\u003c\/strong\u003e: Capable of executing multiple safety functions simultaneously\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Capacity\u003c\/strong\u003e: Sufficient memory to store large programs and data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer : \u003c\/strong\u003eYokogawa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct No. :\u003c\/strong\u003e SCP451-51\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type :\u003c\/strong\u003e Processor Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5 :\u003c\/strong\u003e Standard type with no explosion protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 ：\u003c\/strong\u003eWith ISA Standard G3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight : \u003c\/strong\u003e2 Kg\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42156947013731,"sku":"SCP451-51","price":550.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/SCP451-51_1_c70b81d5-2e28-4e9e-ab97-80013fd78c37.jpg?v=1741072890"},{"product_id":"yokogawa-scp461-11-s1-enhanced-rfi-processor-module","title":"Yokogawa SCP461-11 S1 Enhanced RFI Processor Module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Yokogawa SCP461-11 S1 is a processor module designed for the Yokogawa EXA series Distributed Control System (DCS). This high-performance module is tailored for demanding applications, equipped with a powerful processor and substantial memory capacity, making it ideal for tasks that require high levels of processing power and data throughput. The SCP461-11 S1 also supports a wide range of communication interfaces, facilitating easy connectivity to other devices within the DCS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor\u003c\/strong\u003e: 1.2 GHz dual-core ARM Cortex-A57\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory\u003c\/strong\u003e: 2 GB DDR4 RAM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage\u003c\/strong\u003e: 8 GB eMMC flash memory\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eEthernet 10\/100\/1000Base-T\u003c\/li\u003e\n\u003cli\u003eUSB 2.0\u003c\/li\u003e\n\u003cli\u003eRS-232\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e: -40°C to +85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42157023297635,"sku":"SCP461-11 S1","price":550.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/SCP461-11_1.jpg?v=1741072889"},{"product_id":"yokogawa-cp701-field-control-cpu-module","title":"Yokogawa CP701 Field Control CPU Module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYokogawa CP701 is a Field Control CPU (Central Processing Unit) used in the Yokogawa Field Control Station (FCS) system. It is a rack-mounted unit that provides the processing power and memory for the FCS system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPU:\u003c\/strong\u003e Intel Pentium 4 1.5 GHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e 8 MB SDRAM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage:\u003c\/strong\u003e 128 MB CompactFlash\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\n\u003cstrong\u003eCommunications:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e10 Mbps Ethernet port\u003c\/li\u003e\n\u003cli\u003e2 RS-232C ports\u003c\/li\u003e\n\u003cli\u003e1 RS-485 port\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 100-240 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42369345945699,"sku":"CP701","price":550.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/CP701_2.png?v=1741072796"},{"product_id":"cp345-yokogawa-processor-board-module","title":"CP345 | Yokogawa | Processor Board Module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Yokogawa CP3451 Processor Card Module is a high-performance, real-time processor used in various Yokogawa automation systems. It features a 32-bit PowerPC processor, 1GB of RAM, and 128MB of flash memory. The CP3451 supports multiple communication protocols, including Ethernet, PROFINET, and Modbus.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Yokogawa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e CP3451\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e AAI543-H001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Processor Card Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Origin:\u003c\/strong\u003e Indonesia\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 120 mm x 120 mm x 40 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertificates:\u003c\/strong\u003e CE, RoHS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1 year\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of I\/O Points:\u003c\/strong\u003e Capable of supporting up to 1,536 points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor Speed:\u003c\/strong\u003e Operating at 100 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e 128MB RAM and 128MB flash storage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options:\u003c\/strong\u003e Ethernet, Modbus, Profibus, DeviceNet, ControlNet, Foundation Fieldbus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42472011464803,"sku":"CP345","price":510.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/CP333D_3.jpg?v=1741072892"},{"product_id":"yokogawa-s9981de-01-pressure-transmitter","title":"Yokogawa S9981DE-01 Pressure Transmitter","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S9981DE-01 is a 10 Slot Backplane developed by Yokogawa, designed specifically to interconnect various modules within a control system. It serves as the physical interface allowing modules to communicate effectively with each other.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlots:\u003c\/strong\u003e Accommodates up to 10 modules for diverse application configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectivity:\u003c\/strong\u003e Provides the essential physical connectivity for seamless module interaction and communication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 17.5\" x 5.3\" x 1.0\" (44.5 cm x 13.3 cm x 2.5 cm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 2 lbs 0.3 oz (0.9 kg).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42521142427747,"sku":"S9981DE-01","price":510.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/CP333D_2.jpg?v=1741072891"},{"product_id":"cp451-50-yokogawa-processor-module","title":"CP451-50 | Yokogawa | Processor Module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Yokogawa CP451-50 is a high-performance programmable controller (PLC) module designed to serve as the central processing unit (CPU) within Yokogawa’s CENTUM VP Distributed Control System (DCS). It functions as the “brain” of the DCS, executing control logic, acquiring data from field devices, managing communication with other system components, and interfacing with operators.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Data Handling:\u003c\/strong\u003e Capable of managing complex control algorithms and processing large volumes of data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Memory Capacity:\u003c\/strong\u003e Ample storage for control programs, historical data, and configuration settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Communication:\u003c\/strong\u003e Supports Ethernet, USB, RS-232C, and RS-485 ports for seamless integration with various field devices, operator stations, and other systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e Enhances system reliability and availability with dual-redundant configuration capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Connection:\u003c\/strong\u003e Facilitates direct connection of 2-wire transmitters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPU:\u003c\/strong\u003e 64-bit quad-core running at 2.5GHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e 16GB DDR4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Ports:\u003c\/strong\u003e Ethernet, USB, RS-232C, RS-485\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Support:\u003c\/strong\u003e 16 channels of 4-20 mA signals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Approximately 265 x 305 x 35 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 3.5 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42542294761571,"sku":"CP451-50","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/PW482-10_3_4309b17f-e078-49b7-ba38-96eeb0e2a221.jpg?v=1741072798"},{"product_id":"cp451-10-yokogawa-processor-module","title":"CP451-10 | Yokogawa | Processor Module","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Voltage:\u003c\/strong\u003e 24V DC, 50mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Voltage Range:\u003c\/strong\u003e 20.4~26.4V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput ON Voltage Maximum:\u003c\/strong\u003e 2V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current at Output OFF:\u003c\/strong\u003e 0.1mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load Current:\u003c\/strong\u003e 100mA per channel at 26.4V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 32 channels (digital output)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Approximately 26 x 35 x 25mm (L x W x H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.24 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Performance:\u003c\/strong\u003e The CP451-10 module offers superior processing capabilities, enabling swift execution of control logic and data processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Supports seamless communication and integration with other control systems, PLCs, SCADA systems, or networks, facilitating data exchange and collaborative operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Durability:\u003c\/strong\u003e Designed for robust operation in harsh industrial environments, resisting vibration, humidity, and temperature variations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming \u0026amp; Configuration:\u003c\/strong\u003e Configurable within control systems to meet specific application needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42549022392419,"sku":"Processor Module","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/PW482-10_3_4309b17f-e078-49b7-ba38-96eeb0e2a221.jpg?v=1741072798"},{"product_id":"cp461-10-yokogawa-processor-module","title":"CP461-10 | Yokogawa | Processor Module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: CP461\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Processor Module (for AFV300\/AFV400)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Can be used in a dual-redundant setup with 2 modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Module Compatibility\u003c\/strong\u003e: Supports up to 8 non-standard I\/O modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.7 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight\u003c\/strong\u003e: 2 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42630597312611,"sku":"CP461-10","price":530.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/CP461_3.jpg?v=1741072892"},{"product_id":"yokogawa-cp471-10-processor-module","title":"Yokogawa CP471-10 Processor Module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CP471-10\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003eProcessor Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYokogawa Type Designation:\u003c\/strong\u003ePLC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuffix Code\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1\u003c\/strong\u003e: With explosion protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0\u003c\/strong\u003e: Basic Type\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.45 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42630636798051,"sku":"CP471-10","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/PW482-10_1_caa73efe-2607-4c9f-aa4b-ef54c5552f97.jpg?v=1741072798"},{"product_id":"yokogawa-cp461-51-central-processor-module","title":"Yokogawa CP461-51 Central Processor Module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CP461-51\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003eProcessor Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYokogawa Type Designation:\u003c\/strong\u003ePLC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor\u003c\/strong\u003e: Dual-core ARM Cortex-A57\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClock Speed\u003c\/strong\u003e: 2.0 GHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Systems Supported\u003c\/strong\u003e: Linux, VxWorks, Windows CE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.45 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42630760497251,"sku":"CP461-51","price":530.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/CP461_2.jpg?v=1741072892"},{"product_id":"yokogawa-cp471-51-processor-module","title":"Yokogawa CP471-51 Processor Module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CP471-51\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003eProcessor Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYokogawa Type Designation:\u003c\/strong\u003ePLC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor\u003c\/strong\u003e: High-performance microprocessor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Compatible with CENTUM VP R6.01, R6.02, R6.03, and R6.041\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.45 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42630827180131,"sku":"CP471-51","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/PW482-10_1_caa73efe-2607-4c9f-aa4b-ef54c5552f97.jpg?v=1741072798"},{"product_id":"yokogawa-cp471-50-processor-module-cpu-module","title":"Yokogawa CP471-50 Processor Module CPU Module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CP471-50\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003eProcessor Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYokogawa Type Designation:\u003c\/strong\u003ePLC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Can be used in a dual-redundant configuration on a duplexed field control unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor\u003c\/strong\u003e: High-performance microprocessor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.45 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42630840516707,"sku":"CP471-50","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/PW482-10_1_caa73efe-2607-4c9f-aa4b-ef54c5552f97.jpg?v=1741072798"},{"product_id":"yokogawa-cp401-11-cpu-module","title":"Yokogawa CP401-11 CPU Module","description":"\u003ch2\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CP401-11\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003eProcessor Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYokogawa Type Designation:\u003c\/strong\u003ePLC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Performance CPU\u003c\/strong\u003e: Equipped with a 32-bit RISC processor capable of handling demanding applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Memory Capacity\u003c\/strong\u003e: Offers memory ranging from 256 KB to 4 MB, ideal for storing complex control programs and data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtensive I\/O Capabilities\u003c\/strong\u003e: Supports up to 256 I\/O points, facilitating connectivity with various devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Redundant Architecture\u003c\/strong\u003e: Available in a dual-redundant configuration to enhance system reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPU\u003c\/strong\u003e: 32-bit RISC processor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory\u003c\/strong\u003e: 256 KB to 4 MB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O\u003c\/strong\u003e: Up to 256 I\/O points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication\u003c\/strong\u003e: Vnet\/IP, HKU (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply\u003c\/strong\u003e: 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 50 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -20 to 60 °C (-4 to 140 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40 to 70 °C (-40 to 158 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity\u003c\/strong\u003e: 5 to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration\u003c\/strong\u003e: 0.5 g, 5 to 500 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock\u003c\/strong\u003e: 5 g, 11 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42673668980835,"sku":"CP401-11","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/CP401-11.jpg?v=1741071415"},{"product_id":"yokogawa-cp332d-power-supply-unit","title":"Yokogawa  CP332D Power Supply Unit","description":"\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Yokogawa CP332D is a single-output DC power supply designed to provide reliable power across various applications.\u003cspan\u003e \u003c\/span\u003eIt is compact, lightweight, and offers high efficiency along with low ripple and noise.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSingle-output DC power supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdjustable from 1 V to 40 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdjustable from 0 A to 30 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Specifications:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 100\/200\/240 VAC\u003c\/li\u003e\n\u003cli\u003eFrequency: 47\/63 Hz\u003c\/li\u003e\n\u003cli\u003eCurrent: 10 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Specifications:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: Adjustable from 1 V to 40 V\u003c\/li\u003e\n\u003cli\u003eCurrent: Adjustable from 0 A to 30 A\u003c\/li\u003e\n\u003cli\u003eRipple and Noise: Less than 1 mV RMS\u003c\/li\u003e\n\u003cli\u003eEfficiency: Up to 85%\u003c\/li\u003e\n\u003cli\u003eTemperature Coefficient: 0.005%\/°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Specifications:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: 0°C to 40°C (32°F to 104°F)\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -20°C to 60°C (-4°F to 140°F)\u003c\/li\u003e\n\u003cli\u003eHumidity: 85% RH (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Dimensions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSize: 3U x 19″ x 210 mm (1.18″ x 7.48″ x 8.27″)\u003c\/li\u003e\n\u003cli\u003eWeight: 4.5 kg (9.9 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42675181387875,"sku":"CP332D","price":510.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/CP332D_2.jpg?v=1741071411"},{"product_id":"yokogawa-cp334d-process-control-module","title":"Yokogawa  CP334D Process Control Module","description":"\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Yokogawa CP334D is a V-Net station used in process control systems.\u003cspan\u003e It enables monitoring and control of various process variables, including temperature, pressure, and flow.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e250 mm (W) x 200 mm (H) x 100 mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3.5 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32-bit RISC processor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRAM: 2 MB\u003c\/li\u003e\n\u003cli\u003eFlash memory: 2 MB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 256 I\/O points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eRS-232\u003c\/li\u003e\n\u003cli\u003eRS-485\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42675212714083,"sku":"CP334D","price":510.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/CP334D.jpg?v=1741071410"},{"product_id":"yokogawa-stb4s-00-pressure-clamp-terminal-block","title":"Yokogawa | STB4S-00 | Pressure Clamp Terminal Block","description":"\u003ch3\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYOKOGAWA STB4S-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile terminal unit module designed to facilitate the connection between control systems and field devices. It ensures efficient monitoring and management of industrial processes by providing a reliable interface for digital input signals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003ePressure clamp terminal block\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eReliable digital output interface\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEfficient monitoring and management\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSeamless integration with control systems\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBuilt-in surge absorber (optional)\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePressure clamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32.6 mm x 60.5 mm x 40.8 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Absorber:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptional\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProSafe-RS systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 Kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42786830123107,"sku":"STB4S-00","price":530.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/STB4S-00_2.jpg?v=1741071073"},{"product_id":"f3sp71-4s-yokogawa-sequence-cpu-module","title":"F3SP71-4S | Yokogawa Sequence CPU Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3SP71-4S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Sequence CPU Module from Yokogawa, featuring object ladder programming, multiple I\/O control methods, and built-in communication interfaces for versatile industrial automation applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl Mode\u003c\/strong\u003e: Stored program, repetitive operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Control\u003c\/strong\u003e: Refreshing method and direct I\/O instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgramming Language\u003c\/strong\u003e: Object ladder language\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstruction Set\u003c\/strong\u003e:\u003cbr\u003e • 40 basic instructions\u003cbr\u003e • 445 application instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e:\u003cbr\u003e • USB 2.0 (12 Mbps)\u003cbr\u003e • Ethernet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Card Slot\u003c\/strong\u003e: SD\/SDHC-compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e: Memory, CPU, I\/O error detection, syntax checking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Yokogawa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3SP71-4S\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Sequence CPU Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":43477027487843,"sku":"F3SP71-4S","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/F3SP71-4S_2.jpg?v=1750410969"},{"product_id":"yokogawa-ata4s-s00-s2-pressure-clamp-dcs-terminal","title":"Yokogawa ATA4S-S00 S2 Pressure Clamp DCS Terminal","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ATA4S-S00 S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density interface for signal acquisition within\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control Systems. This 16-channel module captures precise 4–20 mA DC current loops from field transmitters, sensors, and flowmeters. By utilizing a pressure clamp terminal architecture, the ATA4S-S00 S2 ensures secure, gas-tight connections that withstand industrial vibrations. It provides the essential data link required for real-time process monitoring, safety interlocking, and industrial data logging.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: ATA4S\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix\/Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eATA4S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-Channel Analog Input Module (Pressure Clamp)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlways 00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eS2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersion suffix indicating specific hardware revision\/certification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe ATA4S-S00 S2 meets rigorous industrial benchmarks for accuracy and environmental resilience:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 independent channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4–20 mA DC (Typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Method:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePressure clamp terminal block (Tool-free wiring)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eISA G3 Standard (Corrosion resistance)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFull channel-to-channel and channel-to-ground isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP54 equivalent (When correctly installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRack-mounted in DCS I\/O subsystems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.2 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New in original factory packaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eJapan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eISA G3 Corrosion Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ATA4S-S00 S2 complies with the ISA G3 standard, protecting internal circuitry against harsh atmospheric contaminants like Hydrogen Sulfide (\u003cspan class=\"math-inline\"\u003e$H_2S$\u003c\/span\u003e) and Chlorine (\u003cspan class=\"math-inline\"\u003e$Cl_2$\u003c\/span\u003e). This makes it indispensable for wastewater treatment, paper mills, and petrochemical facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration-Proof Pressure Clamps:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe tool-free pressure clamp mechanism eliminates the risk of loose screw terminals. This design maintains constant contact pressure even in high-vibration environments near turbines or heavy pumps, preventing intermittent signal loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Rack Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePacking 16 channels into a compact rack-mount footprint allows engineers to minimize the number of I\/O sub-nests required. This reduces total cabinet space and lowers the overall cost of the control system infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSophisticated isolation barriers shield the system backplane from field-side electrical surges and ground loops. This ensures that a single-channel failure does not propagate to the CPU or disrupt the remaining 15 inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the ATA4S-S00 S2 handle 0–10V voltage signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The ATA4S-S00 S2 is specifically engineered for 4–20 mA current loops. If your application requires voltage inputs, you must utilize a precision shunt resistor or select a different Yokogawa module model such as the AAV series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What are the installation requirements for ISA G3 compliance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo fully leverage the ISA G3 rating, you must install the module within a properly sealed DCS cabinet. The module's conformal coating protects the PCB, but ensuring clean filtered air within the enclosure further extends the lifespan of the entire system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does this module support 2-wire transmitter powering?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ATA4S-S00 S2 primarily acts as the terminal interface. Powering for 2-wire transmitters depends on the specific AAI input module paired with this terminal block. Ensure your system configuration supports the loop power requirements of your field instruments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How do I verify the authenticity of the \"S2\" version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery unit we supply is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e. The \"S2\" revision is verified via the factory serial number and the holographic seals on the Yokogawa original packaging. We provide full traceability for all DCS components.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43802072318051,"sku":"ATA4S-S00 S2","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/35_98230452-0330-427c-bf9c-1afce41c796f.jpg?v=1761808525"},{"product_id":"nfcp502-w05-s1-yokogawa-stardom-fcn-500-cpu-module","title":"NFCP502-W05 S1 Yokogawa STARDOM FCN-500 CPU Module","description":"\u003ch2\u003eYokogawa NFCP502-W05 S1 CPU Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for real-time process control in STARDOM FCN-500 networks, the \u003cstrong\u003eYokogawa NFCP502-W05 S1\u003c\/strong\u003e (\u003cstrong\u003eNFCP502-W05 S1\u003c\/strong\u003e CPU Module) provides direct physical execution of logic processing and system communication.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFCP502-W05 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eDual-core 32-bit RISC, 800 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e256 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e1 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e4 x 10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 128 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 x 28 x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSubject to rack backplane load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and Communication Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eNFCP502-W05 S1\u003c\/strong\u003e utilizes an integrated Vnet\/IP protocol stack to facilitate deterministic communication within distributed control architectures. The module features channel-to-channel isolation on its I\/O expansion bus and supports cold junction compensation (CJC) through connected peripheral I\/O modules when interfacing with thermocouple sensors. Furthermore, the unit manages 4-20 mA HART loop data streams, allowing the processor to execute maintenance diagnostics and configuration parameter tracking directly from field instrumentation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum switchover latency during a redundant CPU failure?\u003c\/p\u003e\n\u003cp\u003eA: The module performs fault detection and automatic switchover in less than 50 ms, ensuring continuous operation during primary processor loss.\u003c\/p\u003e\n\u003cp\u003eQ: Does the NFCP502-W05 S1 support firmware updates without affecting the I\/O scan cycle?\u003c\/p\u003e\n\u003cp\u003eA: The module supports flash memory updates, but the system architecture dictates that primary control functions transition to the standby unit during the update phase to maintain deterministic execution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Interface\u003c\/strong\u003e: Verify that the backplane pins are free of oxidation or debris before mounting the module. Secure the module using the integrated mechanical locking levers to ensure constant pressure on the high-speed data bus connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management\u003c\/strong\u003e: Install the module in a vertical orientation to permit natural convection. Although rated for operation up to 70 deg C, maintain at least 50 mm of clearance above and below the module to avoid thermal throttling of the processor core.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Cabling\u003c\/strong\u003e: Use shielded RJ45 cabling for the 10\/100 Mbps ports. Ensure that the cable shield is terminated at the cabinet entry point to prevent high-frequency EMI\/RFI noise from coupling into the Vnet\/IP communication lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Wiring\u003c\/strong\u003e: When configuring redundant CPU sets, connect both modules to independent power sources and separate network segments. Use the designated sync cable to establish the heartbeat link between the active and standby units.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43856079880291,"sku":"NFCP502-W05 S1","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/167_431bb22d-7dab-49a6-993d-f784d38caf6f.jpg?v=1764124681"},{"product_id":"stardom-fcn-500-cpu-module-yokogawa-nfcp502-s05-s2","title":"STARDOM FCN-500 CPU Module Yokogawa NFCP502-S05 S2","description":"\u003ch2\u003eYokogawa NFCP502-S05 S2 CPU Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa NFCP502-S05 S2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNFCP502-S05 S2\u003c\/strong\u003e CPU Module, operates as a dedicated hardware component for real-time logic execution and system management within STARDOM FCN-500 control networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNFCP502-S05 S2\u003c\/td\u003e\n\u003ctd\u003eStandard STARDOM FCN-500 CPU module with dual-core RISC architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFCP502-S05 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 x 28 x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSubject to system backplane load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eDual-core 32-bit RISC, 800 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e256 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e1 GB (ECC-protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e128 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitchover Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and Communication Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eNFCP502-S05 S2\u003c\/strong\u003e utilizes the Vnet\/IP protocol to ensure deterministic data exchange across distributed control nodes. This module facilitates channel-to-channel isolation on the expansion bus to maintain signal integrity in electrically noisy industrial areas. In addition to standard control tasks, the CPU manages 4-20 mA HART loop data via peripheral I\/O, enabling direct monitoring of field device diagnostics. Cold junction compensation (CJC) for temperature sensing is executed through the integrated I\/O backplane coordination, ensuring precise thermal measurement processing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swapping under full load conditions?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module is designed for hot-swap operations, allowing replacement without interrupting the system I\/O scan or requiring a controller shutdown.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle communication redundancy?\u003c\/p\u003e\n\u003cp\u003eA: The processor utilizes four 10\/100 Mbps Ethernet ports to support redundant network paths. In the event of a link failure, the controller switches to the secondary communication path within the specified fault transition timeframe.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Alignment\u003c\/strong\u003e: Ensure the backplane interface is clear of contaminants. Align the module vertically and engage the locking mechanisms to guarantee electrical contact with the system bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Conditions\u003c\/strong\u003e: Verify that the operating environment remains within -40 deg C to +70 deg C. Provide sufficient vertical airflow to ensure the heat dissipation of the dual-core processor remains within nominal limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding\u003c\/strong\u003e: Connect the module chassis to a dedicated earth ground. Ensure all I\/O signal cabling uses high-quality shielding to maintain EMI\/RFI immunity as per the module specification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Setup\u003c\/strong\u003e: When deploying in a redundant CPU configuration, ensure both modules are synchronized via the dedicated link cable and are connected to isolated power supplies for maximum hardware fault tolerance.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43856086270051,"sku":"NFCP502-S05 S2","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/332_4810bfe5-1882-4ee1-93df-433d34b78058.jpg?v=1764125049"},{"product_id":"nfcp501-s05-s2-yokogawa-stardom-fcn-500-cpu-module","title":"NFCP501-S05 S2 Yokogawa STARDOM FCN-500 CPU Module","description":"\u003ch2\u003eYokogawa NFCP501-S05 S2 CPU Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa NFCP501-S05 S2\u003c\/strong\u003e (\u003cstrong\u003eNFCP501-S05 S2\u003c\/strong\u003e CPU Module) serves as the primary control unit utilized to execute real-time logic and network communication across STARDOM FCN-500 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFCP501-S05 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 x 28 x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSubject to system backplane load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e32-bit RISC, 400 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e128 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e512 MB (ECC-protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e64 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitchover Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Integration and Process Control\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eNFCP501-S05 S2\u003c\/strong\u003e enables deterministic communication via the Vnet\/IP protocol, providing a bridge between local control logic and larger CENTUM VP or ProSafe-RS infrastructures. The module architecture ensures channel-to-channel isolation on the I\/O expansion bus to prevent signal degradation. Furthermore, the unit supports 4-20 mA HART loop protocol connectivity, allowing for the transmission of asset management data and diagnostic parameters from field-level instrumentation directly to the controller memory.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the NFCP501-S05 S2 support hot-swapping during active operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swapping. When configured in a redundant pair, the standby unit maintains the process control state, allowing for the extraction and replacement of the faulty module without system interruption.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module maintain memory integrity during logic execution?\u003c\/p\u003e\n\u003cp\u003eA: The module utilizes ECC-protected memory for both program and data storage, which automatically detects and corrects single-bit errors to ensure logic stability and prevent unexpected controller faults.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Insertion\u003c\/strong\u003e: Align the module with the chassis guide rails. Ensure the connectors are fully seated before engaging the locking levers to maintain stable communication with the backplane bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Controls\u003c\/strong\u003e: Ensure the installation cabinet provides adequate ventilation. Although the module operates up to 60 deg C, maintaining an ambient temperature below 40 deg C prolongs the service life of internal electronic components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Shielding\u003c\/strong\u003e: Use high-quality shielded twisted-pair cabling for all network and I\/O connections. Terminate the shield at the cabinet ground bar to mitigate the effects of electromagnetic interference (EMI) on the communication ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Wiring\u003c\/strong\u003e: When installing in a redundant pair, verify that both CPUs are linked via the dedicated sync cable. Ensure power supplies are derived from independent, fault-tolerant sources to prevent a single power failure from disabling the redundant control set.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43856088137827,"sku":"NFCP501-S05 S2","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/331_d50d4c55-b756-492e-a8c2-fa921379af37.jpg?v=1764125432"},{"product_id":"yokogawa-nfcp501-s05-s2-stardom-fcn-500-cpu-module","title":"Yokogawa NFCP501-S05 S2 STARDOM FCN-500 CPU Module","description":"\u003ch2\u003eYokogawa NFCP501-S05 S2 CPU Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa NFCP501-S05 S2\u003c\/strong\u003e (\u003cstrong\u003eNFCP501-S05 S2\u003c\/strong\u003e CPU Module) serves as the primary control unit utilized to execute real-time logic and network communication across STARDOM FCN-500 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFCP501-S05 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 x 28 x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSubject to system backplane load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e32-bit RISC, 400 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e128 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e512 MB (ECC-protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e64 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitchover Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Integration and Process Control\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eNFCP501-S05 S2\u003c\/strong\u003e enables deterministic communication via the Vnet\/IP protocol, providing a bridge between local control logic and larger CENTUM VP or ProSafe-RS infrastructures. The module architecture ensures channel-to-channel isolation on the I\/O expansion bus to prevent signal degradation. Furthermore, the unit supports 4-20 mA HART loop protocol connectivity, allowing for the transmission of asset management data and diagnostic parameters from field-level instrumentation directly to the controller memory.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the NFCP501-S05 S2 support hot-swapping during active operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swapping. When configured in a redundant pair, the standby unit maintains the process control state, allowing for the extraction and replacement of the faulty module without system interruption.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module maintain memory integrity during logic execution?\u003c\/p\u003e\n\u003cp\u003eA: The module utilizes ECC-protected memory for both program and data storage, which automatically detects and corrects single-bit errors to ensure logic stability and prevent unexpected controller faults.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Insertion\u003c\/strong\u003e: Align the module with the chassis guide rails. Ensure the connectors are fully seated before engaging the locking levers to maintain stable communication with the backplane bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Controls\u003c\/strong\u003e: Ensure the installation cabinet provides adequate ventilation. Although the module operates up to 60 deg C, maintaining an ambient temperature below 40 deg C prolongs the service life of internal electronic components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Shielding\u003c\/strong\u003e: Use high-quality shielded twisted-pair cabling for all network and I\/O connections. Terminate the shield at the cabinet ground bar to mitigate the effects of electromagnetic interference (EMI) on the communication ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Wiring\u003c\/strong\u003e: When installing in a redundant pair, verify that both CPUs are linked via the dedicated sync cable. Ensure power supplies are derived from independent, fault-tolerant sources to prevent a single power failure from disabling the redundant control set.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43856089808995,"sku":"NFCP501-S05 S1","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/167.1_91e816e3-762e-47c0-b872-5494a78beee4.jpg?v=1764125867"},{"product_id":"yokogawa-nfcp501-w15-s2-stardom-fcn-500-cpu-processor-module","title":"Yokogawa NFCP501-W15 S2 STARDOM FCN-500 CPU Processor Module","description":"\u003ch2\u003eYokogawa NFCP501-W15 S2 CPU Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed deterministic process control within STARDOM FCN-500 autonomous controller platforms, the \u003cstrong\u003eYokogawa NFCP501-W15 S2\u003c\/strong\u003e (\u003cstrong\u003eNFCP501-W15 S2\u003c\/strong\u003e) CPU Module provides direct physical and electrical execution of complex control logic and supervisory functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFCP501-W15 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e65.8 x 130 x 149.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e20 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC (+\/- 5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e32-bit high-performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e1 GB RAM, 2 GB Flash, 2 MB SRAM (ECC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDistributed Control and Communication Integrity\u003c\/h3\u003e\n\u003cp\u003eThe NFCP501-W15 S2 module facilitates process synchronization via four high-speed Ethernet ports, supporting fieldbus connectivity and DCS integration. The onboard 2 MB SRAM features Error Correction Code (ECC) and battery-backed retention, ensuring data consistency during power cycles. Communication latencies are minimized through a real-time operating system (RTOS) kernel, which enforces deterministic network throughput. To maintain system stability, operators must ensure that firmware flash compatibility is verified against the existing STARDOM controller backplane bus. Proper channel-to-channel isolation and surge voltage protection limits are integrated into the module hardware to prevent external interference from propagating into the control logic execution path.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the NFCP501-W15 S2 support redundant CPU configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports dual-CPU redundancy when installed in compatible FCN-500 base plates. Switchover latency is managed by the internal redundancy protocol to ensure uninterrupted process control.\u003c\/p\u003e\n\u003cp\u003eQ: How is the battery-backed SRAM utilized?\u003c\/p\u003e\n\u003cp\u003eA: The 2 MB SRAM stores critical runtime parameters and process variables that require persistence during temporary power loss. The internal battery provides the necessary voltage to maintain this memory state for defined intervals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the module into the designated slot on the FCN-500 base plate. Use the integrated locking mechanisms to ensure the connector pins are fully engaged with the backplane bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the module's functional earth terminal to the cabinet ground bus using a low-impedance copper strap to minimize high-frequency noise and surge voltage propagation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectivity:\u003c\/strong\u003e Utilize category 6 or higher shielded twisted-pair cables for Ethernet communication ports to maintain data integrity and protocol conversion latencies within specified limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the control cabinet provides active ventilation to keep ambient temperatures within the 0 deg C to +55 deg C range. Avoid mounting the module near high-power electromagnetic sources to prevent crosstalk.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43856101671011,"sku":"NFCP501-W15 S2","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/14_cc12ef58-c1ca-4226-a929-b84253e061b4.jpg?v=1764126631"},{"product_id":"yokogawa-f3ad08-4w-high-speed-a-d-conversion-module-for-plc","title":"Yokogawa F3AD08-4W | High-Speed A\/D Conversion Module for PLC","description":"\u003ch2\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3AD08-4W\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial automation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocess control\u003c\/strong\u003e. Part of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFA-M3 PLC series\u003c\/strong\u003e, this module acquires analog signals from field devices like transmitters, sensors, and controllers, converting them into digital values that can be processed by Yokogawa's\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLC systems\u003c\/strong\u003e. It is built for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed A\/D conversion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand is essential for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand control in modern automation systems.\u003c\/p\u003e\n\u003cp\u003eWith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 analog input channels\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3AD08-4W\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers versatility in handling both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evoltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecurrent input signals\u003c\/strong\u003e, making it suitable for a wide range of industrial applications. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecompact design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures efficient use of rack space, while\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh accuracy\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereliable operation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensure continuous performance in demanding environments.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage: ±10 V, 0–10 V, 1–5 V\u003cbr\u003eCurrent: 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12–16 bit A\/D conversion (depending on configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1% of span (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh impedance for voltage input; approx. 250 Ω for current input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel-to-ground isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUpdate Cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypically ≤ 1 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–10 °C to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–20 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFA-M3 PLC series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOO (Certificate of Origin), CE, UL (depending on version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18-point terminal block, M3.5 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (External)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.9 (W) × 100 (H) × 106.1 (D) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (External)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingapore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What types of signals can the F3AD08-4W handle?\u003c\/strong\u003e\u003cbr\u003eThe F3AD08-4W supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evoltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignals (±10 V, 0–10 V, 1–5 V) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecurrent\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignals (4–20 mA), making it highly versatile for a range of industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How fast is the A\/D conversion process?\u003c\/strong\u003e\u003cbr\u003eThe F3AD08-4W features an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA\/D conversion cycle of ≤1 ms per channel\u003c\/strong\u003e, enabling real-time data acquisition and control for fast-moving industrial processes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the accuracy of the F3AD08-4W?\u003c\/strong\u003e\u003cbr\u003eThe module provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±0.1% accuracy\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(typical), ensuring precise and reliable signal conversion for critical applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can this module integrate with Yokogawa FA-M3 PLC systems?\u003c\/strong\u003e\u003cbr\u003eYes, the F3AD08-4W is designed to seamlessly integrate with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa FA-M3 PLC systems\u003c\/strong\u003e, ensuring compatibility with your existing control systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What is the operating temperature range for this module?\u003c\/strong\u003e\u003cbr\u003eThe F3AD08-4W can operate in a temperature range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e–10 °C to +55 °C\u003c\/strong\u003e, making it suitable for a wide variety of industrial environments.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":43891528663139,"sku":"F3AD08-4W","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/368._823b2b12-44bc-4453-9364-8a19552e44f9.jpg?v=1765767374"},{"product_id":"yokogawa-ant502-53-esb-optical-communication-repeater","title":"Yokogawa ANT502-53 ESB Optical Communication Repeater","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eYOKOGAWA ANT502-53 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an Optical ESB Bus Repeater Slave Module designed to extend ESB bus communication distances within Yokogawa distributed control systems. The module converts electrical ESB bus signals into optical signals, enabling long-distance, noise-immune communication across large industrial facilities.\u003c\/p\u003e\n\u003cp\u003eIt is commonly deployed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems and works in conjunction with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFIO and N-IO architectures\u003c\/strong\u003e, providing stable and reliable ESB bus extension in environments where electrical transmission limits or electromagnetic interference are concerns.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eANT502-53\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a slave-side optical repeater on the ESB bus. By converting electrical signals to optical fiber transmission, it allows ESB networks to span long distances while maintaining signal integrity and deterministic communication behavior.\u003c\/p\u003e\n\u003cp\u003eIts design supports flexible network topologies and redundant bus configurations, making it suitable for high-availability control systems deployed over wide plant areas.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical \u0026amp; Communication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Conversion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical ESB bus ⇔ Optical fiber\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication Speed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eESB bus standard, up to 1.25 Mbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eTransmission Distance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 5 km per optical hop\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eRedundancy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports dual redundant ESB bus connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eYokogawa CENTUM VP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFIO and N-IO subsystem architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eESB-based control and I\/O networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 155.9 × 130 × 32.8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight:  0.2–0.25 kg (configuration dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation: Rack or panel mounting, compact form factor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -20 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative Humidity: 10% to 90% RH, non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Documentation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCertificate of Origin (COO)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory Test Report available\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43983263400035,"sku":"ANT502-53","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/57._d7df1b6e-5da0-4b91-80d9-5e4c05f6733a.jpg?v=1770082094"},{"product_id":"ec401-50-s3-esb-communication-module-yokogawa","title":"EC401-50 S3 ESB Communication Module | Yokogawa","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eYOKOGAWA EC401-50 S3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an ESB Bus Coupler Module designed for Yokogawa\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP Distributed Control Systems\u003c\/strong\u003e. The module functions as an ER bus interface within ESB bus architectures, enabling reliable communication between local ESB bus nodes, Compact Field Control Units (FCUs), and remote ER bus segments.\u003c\/p\u003e\n\u003cp\u003eInstalled inside ESB Bus Node Units or Compact FCUs, this module provides stable, deterministic data exchange for distributed control environments where communication reliability and expandability are critical.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEC401-50 S3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a communication interface module that links ESB-based control components to ER bus networks. It enables structured data transfer between local controllers and remote nodes while supporting redundant configurations for high-availability system designs.\u003c\/p\u003e\n\u003cp\u003eWhen two modules are installed, the system supports dual-redundant ER bus communication, improving fault tolerance and maintaining continuous operation during module or network failures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication Protocol: ER bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePhysical Layer: IEEE 802.3 10BASE-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTransmission Medium: Coaxial cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Type: BNC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication Speed: 10 Mbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Transmission Distance: Up to 500 m per segment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCENTUM VP Distributed Control System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eESB Bus Node Units: ANB10S, ANB10D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact FCUs: AFF50S, AFF50D, AFV10S, AFV10D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply: Provided by host ESB Bus Node Unit or Compact FCU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption: Low-power design optimized for continuous operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 22 × 124 × 126 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.1–0.3 kg (installation dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation Method: Plug-in module for ESB nodes and Compact FCUs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -20 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative Humidity: 10% to 90% RH, non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43983265824867,"sku":"EB401-50 S3","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/58._18f6ad3f-c431-4108-8f32-e08855d42515.jpg?v=1770082422"},{"product_id":"scp461-11-yokogawa-cs-3000-system-controller-board","title":"SCP461-11 Yokogawa CS 3000 System Controller Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa SCP461-11 (SCP461 11) serves as the primary central processing unit (CPU) for Field Control Stations within the CENTUM VP and CS 3000 Distributed Control Systems (DCS). This 100% brand new, original module executes complex control algorithms, manages high-speed signal processing, and coordinates communication across the control network. As the functional core of the system, it integrates seamlessly with safety control units like the SSC60 and S2SC70, ensuring synchronized operation across the plant's automation layers. Engineered for mission-critical industrial environments, the SCP461-11 provides the high-integrity logic execution required for large-scale refineries, chemical plants, and power generation facilities.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eYokogawa SCP461 series modules utilize specific coding to define hardware revisions and functional compatibility:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\/Suffix\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSCP461\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic Processor Module Model\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-11\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpecific hardware revision \/ standard performance version\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-51\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-availability or specialized variant (alternative model)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eS1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard system designation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe SCP461-11 utilizes Japanese precision engineering to maintain stable performance in high-interference settings.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa (Japan)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCENTUM VP, CS 3000 DCS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Unit Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSSC60, S2SC70 Safety Control Units\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnhanced EMI (Electromagnetic) and RFI (Radio Frequency) Shielding\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e199.5 × 146.5 × 32.8 mm (Standard configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg to 0.7 kg (Card weight only)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eField Control Station Baseplate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLogic Execution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReal-time multi-loop control and signal processing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Factory New and Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa SCP461-11 addresses the challenges of high-density process control and electrical noise:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior EMI\/RFI Hardening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module features robust shielding that prevents electromagnetic and radio frequency interference from disrupting CPU operations. This ensures stable logic execution even when installed near high-voltage switchgear or heavy industrial motors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSynchronized Safety Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe processor maintains tight timing synchronization with Yokogawa’s safety-related control units. This synergy allows for unified control and safety strategies, reducing the complexity of the total system architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Logic Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe SCP461-11 architecture prioritizes real-time signal processing. It ensures that critical control loops execute at consistent intervals, preventing process jitter and maintaining product quality in high-speed manufacturing environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Quality Standards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManufactured in Japan, this module meets rigorous international standards for durability and reliability. The hardware withstands the thermal stresses of continuous 24\/7 industrial operation, minimizing the risk of unplanned system shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the SCP461-11 in a standard PLC rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The SCP461-11 is a specialized DCS processor module designed exclusively for Yokogawa CENTUM VP and CS 3000 baseplates. It utilizes a proprietary backplane interface that is not compatible with generic PLC hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the -11 and -51 versions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSuffixes like -11 and -51 typically denote different hardware revisions or specific software compatibility tiers within the CENTUM series. While they often perform the same primary functions, you must consult your system's original engineering documentation to ensure the specific revision matches your Field Control Station's requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require special expertise for installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Integrating an SCP461-11 requires a trained automation engineer familiar with Yokogawa's engineering environment. The module requires specific software configuration and system loading to recognize the I\/O bus and control logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the typical shipping lead time for this part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile some configurations may show an estimated lead time of 10-12 weeks from the factory, we frequently maintain ready stock for immediate shipment within 1–3 working days via global carriers like DHL or FedEx.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44121929023587,"sku":"SCP461-11","price":240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/77._30636671-d1a9-40f6-9f09-984aac13adae.jpg?v=1776417499"},{"product_id":"scp461-e1-yokogawa-400mhz-processor-module-for-centum-vp","title":"SCP461-E1 Yokogawa 400MHz Processor Module for CENTUM VP","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa SCP461-E1 (SCP461 E1) functions as the high-availability central processing unit for the CENTUM VP distributed control system (DCS). This 100% brand new, original module acts as the primary intelligence for AFV30S and AFV40S Field Control Units, executing complex process control logic and managing high-speed data acquisition across the plant floor. Engineered for mission-critical reliability, the SCP461-E1 supports Yokogawa's proprietary \"Pair \u0026amp; Spare\" redundancy architecture. This hardware-level synchronization ensures continuous plant operation even during a processor failure. By integrating a 400 MHz RISC processor and Vnet\/IP communication capabilities, the SCP461-E1 delivers the deterministic scan rates required for large-scale refineries, chemical processing, and energy infrastructure.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe SCP461-E1 utilizes specific suffixes to denote its functional tier and system compatibility:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix\/Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSCP461\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Processor Module Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-E1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnhanced performance version (Vnet\/IP support)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eS2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpecific system revision \/ configuration designation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe SCP461-E1 combines high-speed memory with industrial-grade environmental protection to maintain long-term system stability.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMain Processor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32-bit RISC Industrial Processor (400 MHz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMain Memory (RAM)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128 MB high-speed SDRAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNon-Volatile Storage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e512 MB Flash (Firmware \u0026amp; Configuration backup)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVnet\/IP (100 Mbps redundant Ethernet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDuplexed “Pair \u0026amp; Spare” with auto-sync\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISA Standard G3 compliant (Conformal Coating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in battery backup for volatile data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 50°C (32–122°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e199.5 mm × 146.5 mm × 32.8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.75 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa SCP461-E1 addresses the most demanding industrial automation requirements through specialized hardware features:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUninterrupted \"Pair \u0026amp; Spare\" Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports dual-redundant configurations where two processors run identical logic simultaneously. If the active unit detects an internal discrepancy, the standby unit takes control without a single millisecond of lag. This eliminates process \"bumps\" and prevents safety-related shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eISA G3 Corrosive Gas Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa applies a specialized conformal coating to the SCP461-E1 circuitry, meeting ISA Standard G3. This protection prevents copper and silver corrosion in environments containing sulfur or chlorine, such as wastewater treatment or chemical synthesis plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVnet\/IP Deterministic Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes a Vnet\/IP interface to ensure high-speed, 100 Mbps communication with other control stations. This protocol prioritizes control traffic over general data, guaranteeing that critical alarms reach the operator console without network congestion delays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow-Latency Logic Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 400 MHz RISC processor manages high-density I\/O (up to thousands of points) while maintaining fast, predictable scan rates. This computational power allows for the implementation of advanced control strategies like multivariable predictive control (MPC) directly at the FCU level.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the SCP461-11 and the SCP461-E1?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe SCP461-E1 features a significantly faster processor (400 MHz) and expanded memory (128 MB RAM \/ 512 MB Flash) compared to earlier revisions. It specifically supports Vnet\/IP communication for modern AFV30S and AFV40S Field Control Units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the battery backup system work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module includes a built-in battery that maintains the volatile SDRAM during a total power failure. This preserves the current process state and variable values, enabling the controller to resume operation instantly once power returns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module interchangeable with generic PLCs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The SCP461-E1 is a proprietary Yokogawa DCS component. It requires a specific Yokogawa backplane and CENTUM VP engineering software for configuration. It will not function in standard third-party PLC racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace a failed module while the system is running?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf your system utilizes a duplexed (redundant) setup, you can replace the failed SCP461-E1 without shutting down the process. The healthy processor automatically synchronizes its data and logic to the new module once it is inserted into the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44121932333155,"sku":"SCP461-E1","price":240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/67._5320ddb6-165f-49f1-98ca-2b135dcff3fe.jpg?v=1776417807"},{"product_id":"cp471-50-yokogawa-centum-vp-processor-module-cpu","title":"CP471-50 Yokogawa CENTUM VP Processor Module CPU","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa CP471-50 (CP471 50) serves as the primary processing engine for the CENTUM VP Field Control Stations (FCS). This 100% brand new, original module executes complex industrial control logic, manages real-time communication across the Vnet\/IP network, and processes critical field data. Designed as a high-performance upgrade and direct replacement for the legacy CP461 series, the CP471-50 supports advanced Field Control Units including the AFV30, AFV40, A2FV50, and A2FV70. It provides the computational power necessary for modern, high-density I\/O environments while maintaining the strict deterministic timing required for large-scale process automation.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eYokogawa CP471 modules utilize specific suffix codes to define environmental protection and safety tiers:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCP471\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Processor Module Model\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-5\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard type (No explosion protection)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic type configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\/G3\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISA Standard G3 Conformal Coating (Optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\/ERFI\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnhanced RFI (Radio Frequency Interference) Resistance (Optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe CP471-50 integrates high-speed logic execution with robust physical hardware protection.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation (Japan)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProcessor Module (CPU)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAFV30, AFV40, A2FV50, A2FV70\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSoftware Requirement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCENTUM VP R6.05 or later\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware Requirement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEC401 Bus Coupler (Style S3 or later)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports Dual-Redundant Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e199.5 mm × 149 mm × 32.8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.7 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard industrial environment (Non-Explosion Protected)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa CP471-50 addresses the evolving needs of process plants by offering superior reliability and lifecycle management:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZero-Downtime Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports on-line replacement. In a dual-redundant configuration, you can swap a faulty CP471-50 while the sister module maintains active control of the process, eliminating the need for costly plant shutdowns during maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Migration Path:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa designed the CP471-50 as a direct functional replacement for the older CP461-10 and CP461-50 modules. This allows plant managers to upgrade their processing power and extend the system lifecycle without redesigning the existing cabinet infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Fault Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy installing two CP471-50 modules in a duplexed arrangement, the system achieves full hardware redundancy. The processors synchronize data in real-time, providing an instantaneous failover mechanism that protects the process from a single point of failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Hardening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features superior EMI\/RFI resistance. This shielding ensures that electrical noise from high-capacity pumps, drives, or radio equipment does not interfere with the sensitive control logic execution, maintaining signal purity in harsh industrial zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the CP471-50 to replace a CP461-10 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The CP471-50 serves as a direct replacement for the CP461 series. However, ensure your system runs CENTUM VP software version R6.05 or later to support the newer hardware architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific bus coupler?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. To ensure full functionality and communication stability, the CP471-50 requires the EC401 ESB Bus Coupler module with a style code of S3 or later.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle corrosive environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the standard CP471-50 is robust, Yokogawa offers an optional ISA Standard G3 conformal coating (\/G3). This coating protects the internal circuitry from corrosive gases like hydrogen sulfide and chlorine, common in paper mills and chemical plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum number of I\/O modules one CP471-50 can manage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn a standard configuration, the processor manages up to 8 I\/O modules directly, though total system capacity depends on the specific Field Control Unit chassis and expansion bus configuration used.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44121933086819,"sku":"CP471-50","price":240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/56_e6c3c97f-4a50-4679-b8a7-7e798787b4b8.jpg?v=1776418144"},{"product_id":"new-original-yokogawa-cp451-51-32-bit-risc-processor","title":"New Original Yokogawa CP451-51 32-bit RISC Processor","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Yokogawa CP451-51 (CP451 51) functions as the high-integrity central processing unit for CENTUM VP Field Control Units,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003especifically the AFV300 and AFV400 series (also compatible with AFV10S\/D).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis 100% brand new,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoriginal module executes the core control logic,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emanages complex data acquisition,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand coordinates multi-protocol communication for large-scale industrial plants.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEngineered to replace the legacy CP451-11,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe CP451-51 integrates a 32-bit RISC processor to handle continuous,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esequential,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand batch control tasks with high precision.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts specialized architecture supports dual-redundant \"hot\" standby modes,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that critical process loops remain active even during hardware maintenance or unforeseen faults.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe CP451-51 utilizes specific suffix codes to define its environmental and safety rating:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCP451\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Processor Module Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-5\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard type (No explosion protection)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISA Standard G3 conformal coating for corrosion resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe CP451-51 combines industrial-grade memory retention with high-speed computational power.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMain Processor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32-bit RISC (VR5432, 133 MHz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMain Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Retention\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 72 hours via S9129FA Backup Battery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus (RTU\/ASCII), Ethernet, Fieldbus, Profibus-DP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports dual-module hot redundancy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Management\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHandles signal conversion, alarm processing, and trend recording\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 55°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65 (Front panel dust and splash resistance)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 20 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e48 × 96 × 140 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Yokogawa CP451-51 addresses the challenges of harsh industrial environments and mission-critical uptime:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eG3-Level Environmental Resilience:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module features an ISA Standard G3 compliant conformal coating.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis protective layer prevents circuit board corrosion caused by sulfur dioxide,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003echlorine,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor high humidity,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it the ideal choice for petrochemical refineries and wastewater treatment plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eZero-Interruption Failover:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhen paired in a duplexed configuration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003etwo CP451-51 modules synchronize their internal data registers in real-time.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIf the primary CPU fails,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe secondary module assumes control within milliseconds,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epreventing process \"bumps\" and ensuring continuous safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMulti-Protocol Communication Hub:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe processor manages multiple interfaces including RS-232C,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRS-422\/485,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand LAN.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis flexibility allows the CENTUM VP system to integrate seamlessly with third-party PLCs,\u003c\/span\u003e\u003cspan\u003e gas chromatographs,\u003c\/span\u003e\u003cspan\u003e and power management systems through Modbus or Profibus-DP.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Data Integrity:\u003c\/strong\u003e\u003cspan\u003e An integrated S9129FA battery preserves the 32 MB SDRAM for up to 72 hours during a complete power loss.\u003c\/span\u003e\u003cspan\u003e This ensures the controller retains its current logic state and historical trend data,\u003c\/span\u003e\u003cspan\u003e facilitating a safe and rapid recovery once power returns.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the CP451-51 replace an existing CP451-11 module?\u003c\/strong\u003e\u003cspan\u003eYes.\u003c\/span\u003e\u003cspan\u003e The CP451-51 serves as a direct,\u003c\/span\u003e\u003cspan\u003e high-performance replacement for the CP451-11.\u003c\/span\u003e\u003cspan\u003e It offers identical physical dimensions and mounting specifications for a seamless \"drop-in\" upgrade.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific rack?\u003c\/strong\u003e\u003cspan\u003eThe CP451-51 installs specifically into AFV300,\u003c\/span\u003e\u003cspan\u003e AFV400,\u003c\/span\u003e\u003cspan\u003e AFV10S,\u003c\/span\u003e\u003cspan\u003e and AFV10D Field Control Unit racks.\u003c\/span\u003e\u003cspan\u003e It is not compatible with generic PLC or non-Yokogawa backplanes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the ISA G3 option?\u003c\/strong\u003e\u003cspan\u003eThe G3 rating means the module's electronic components are protected against highly corrosive atmospheres.\u003c\/span\u003e\u003cspan\u003e This is a critical requirement for plants located in industrial zones with high levels of chemical pollutants that would otherwise cause premature hardware failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I manage the backup battery?\u003c\/strong\u003e\u003cspan\u003eThe system provides low-battery diagnostics via the CENTUM VP software.\u003c\/span\u003e\u003cspan\u003e To maintain data retention capabilities,\u003c\/span\u003e\u003cspan\u003e you must recharge the battery for a minimum of 48 hours upon initial installation or after a long period of storage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44121934037091,"sku":"CP451-51","price":240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/57_38e5a2c8-77f6-49d4-986b-54c43e878616.jpg?v=1776418540"},{"product_id":"yokogawa-cp461-51-s2-centum-vp-control-processor-module","title":"Yokogawa CP461-51 S2 CENTUM VP Control Processor Module","description":"\u003ch2\u003eYokogawa CP461-51 S2 CENTUM Control Processor Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for real-time control logic execution and process data processing in Field Control Units (FCUs), the \u003cstrong\u003eYokogawa CP461-51 S2\u003c\/strong\u003e (\u003cstrong\u003eCP461\u003c\/strong\u003e Control Processor Module) provides direct physical and electrical execution of DCS control loops across CENTUM VP and CS 3000 platforms. The hardware coordinates high-speed signal flow through dual-redundant Vnet\/IP network interfaces to prevent control loop interruption. Integrated battery-backed main memory retains process state data for up to 72 hours during power outages, while strict backplane bus isolation isolates sensitive central processing logic from field transients.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe suffix structure of the CP461 processor module indicates specific functional capabilities and hardware revisions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model (CP461):\u003c\/strong\u003e Standard CENTUM series high-speed central processing unit card architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirst Suffix (-51):\u003c\/strong\u003e Designates enhanced environmental resistance options and specific board-level hardware assembly configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecond Suffix (S2):\u003c\/strong\u003e Specifies the hardware revision level and firmware compatibility baseline.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP461-51 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.70 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e199.5 mm x 146.5 mm x 16.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP \/ CENTUM CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDistributed Control System (DCS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eCompatible Field Control Unit (FCU) chassis slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eDual-redundant Vnet\/IP control bus protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Backup\u003c\/td\u003e\n\u003ctd\u003eBattery backup holding main memory for up to 72 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Recharge Time\u003c\/td\u003e\n\u003ctd\u003e48 hours minimum for full capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Features\u003c\/h3\u003e\n\u003cp\u003eThe CP461-51 S2 interfaces directly with field I\/O racks over deterministic Vnet\/IP control loops. Channel-to-channel isolation circuits suppress ground potential differences across field wiring barriers. The processor card continuously calculates cold junction compensation values for temperature loops and processes 4-20 mA HART instrumentation data without degrading scan cycles. Operating in dual-redundant pairs, the card synchronizes internal memory structures across the backplane bus to ensure seamless failover during hardware fault conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can an engineer mix a CP461-51 S2 module with a CP471 processor in a dual-redundant processor pair?\u003c\/p\u003e\n\u003cp\u003eA: Engineers must never mix CP461 and CP471 modules within the same dual-redundant processor slot pair. Both slots in a redundant Field Control Unit require identical processor model numbers and matching hardware revision codes to enable memory synchronization and automatic failover functions.\u003c\/p\u003e\n\u003cp\u003eQ: How long does the internal backup battery maintain main memory during a total power disruption?\u003c\/p\u003e\n\u003cp\u003eA: The onboard backup system preserves main memory contents for up to 72 hours following a complete power loss. After external power restoration, the system requires a minimum 48-hour continuous recharge cycle to return the battery to full backup capacity.\u003c\/p\u003e\n\u003cp\u003eQ: What is the procedure for replacing a failed CP461-51 S2 in an active redundant system?\u003c\/p\u003e\n\u003cp\u003eA: Technicians can pull the faulted module from its slot while the backup module continues process execution without interruption. Inserting the replacement CP461-51 S2 into the backplane triggers an automatic state copy, copying memory tables and aligning firmware states before re-establishing redundant backup mode.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eSlide the CP461-51 S2 vertically along the card guides of the assigned Field Control Unit slot until the rear backplane connectors align. Apply steady inward pressure on the front panel faceplate to lock the card into the backplane socket, then tighten the upper and lower retaining screws to a torque of 0.5 Nm. Ensure the cabinet earth ground connects directly to the system ground bus with a heavy copper conductor having a path resistance below 1 Ohm. Route all Vnet\/IP network communications cabling in dedicated wire ducts, maintaining a minimum clearance of 200 mm from high-voltage AC lines to prevent signal distortion.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67676846719075,"sku":"CP461-51-S2","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/345._621217ad-096d-44cc-a209-474db8ac6453.jpg?v=1791616339"},{"product_id":"scp451-51-s2-yokogawa-prosafe-rs-safety-processor-module","title":"SCP451-51 S2 Yokogawa ProSafe-RS Safety Processor Module","description":"\u003ch2\u003eYokogawa SCP451-51 S2 ProSafe-RS Safety Processor Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa SCP451-51 S2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSCP451\u003c\/strong\u003e Safety Processor Module, operates as a dedicated hardware component for real-time safety logic execution and process data coordination within ProSafe-RS Safety Instrumented System (SIS) platforms. The unit processes deterministic safety algorithms across backplane buses to manage active emergency shutdown (ESD) loops and process interlocks. Integrated memory buffers retain processor state data during system power interruptions, while channel-to-channel galvanic isolation prevents field electrical transients from affecting internal core microprocessors.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe suffix structure of the SCP451 safety processor module designates mechanical specifications and environmental protective options applied during production:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model (SCP451):\u003c\/strong\u003e Standard ProSafe-RS high-reliability safety processor module platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirst Suffix (-51):\u003c\/strong\u003e Designates non-explosion-proof construction combined with factory-applied conformal coating specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecond Suffix (S2):\u003c\/strong\u003e Indicates the specific hardware revision level and firmware baseline compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSCP451-51 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e102 mm x 38 mm x 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eProSafe-RS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSafety Instrumented System (SIS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC +\/-10 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS-485 \/ Backplane Safety Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Features\u003c\/h3\u003e\n\u003cp\u003eThe SCP451-51 S2 routes safety logic commands across redundant control buses to preserve process availability without single-point failure risks. Integrated channel-to-channel isolation circuits prevent ground loops and field voltage surges from degrading core processing performance. The module processes analog trip thresholds and cold junction compensation values received from remote I\/O units, enforcing active safety interlocks within deterministic system scan times.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What precautions are necessary when hot-swapping an SCP451-51 S2 module in a redundant configuration?\u003c\/p\u003e\n\u003cp\u003eA: Technicians must verify that the partner processor in the dual-redundant Safety Control Unit is fully online and displaying active diagnostic health LEDs before extracting the faulty module. Upon seating the replacement card, the backplane automatically synchronizes memory tables and aligns firmware execution states.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle power supply fluctuations within the control panel?\u003c\/p\u003e\n\u003cp\u003eA: The module accepts a nominal input voltage of 24 VDC with a +\/-10 percent tolerance window. Internal voltage regulation circuitry steps down field power to a regulated 5 VDC rail for internal logic circuits, filtering high-frequency noise and voltage sags.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInsert the SCP451-51 S2 vertically into the designated Safety Control Unit rack slot, guiding the board along the chassis rails until the rear backplane connectors engage firmly. Secure the top and bottom retaining screws to a torque spec of 0.5 Nm to prevent connection looseness caused by industrial panel vibration. Ensure the main cabinet ground connects directly to the system earth bar with heavy copper wire, keeping path resistance under 1 Ohm to maintain effective shield grounding. Route RS-485 and safety network cables through separate wire ducts, maintaining a minimum physical separation of 200 mm from AC power conductors to suppress electromagnetic interference.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67676865396835,"sku":"SCP451-51 S2","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/919._e31f5bf3-d9c4-4690-9f9c-b3596413e111.jpg?v=1791616570"},{"product_id":"scp451-51-s1-yokogawa-safety-processor-module-order-online","title":"SCP451-51 S1 Yokogawa Safety Processor Module | Order Online","description":"\u003ch2\u003eYokogawa SCP451-51 S1 ProSafe-RS Safety Processor Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa SCP451-51 S1\u003c\/strong\u003e serves as the primary \u003cstrong\u003eSCP451\u003c\/strong\u003e Safety Processor Module utilized to execute real-time safety logic across ProSafe-RS platforms. Mounted inside SSC50S\/D or SSC57S\/D Safety Control Units, the unit processes application programs to trigger active emergency shutdown (ESD) routines and safety interlocks. Deterministic communication travels over Vnet\/IP network channels to coordinate field data across redundant controller configurations. Channel-to-channel galvanic isolation prevents signal degradation across backplane circuits while non-explosion-protected construction ensures stable continuous execution in controlled hardware enclosures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe suffix structure of the SCP451 platform defines physical protection options and internal hardware revisions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model (SCP451):\u003c\/strong\u003e Standard ProSafe-RS safety processor module hardware architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirst Suffix (-51):\u003c\/strong\u003e Standard industrial enclosure build designated as non-explosion-proof type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecond Suffix (S1):\u003c\/strong\u003e Hardware design revision level and internal firmware baseline release.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSCP451-51 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.70 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 mm x 60 mm x 210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eProSafe-RS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSafety Instrumented System (SIS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controllers\u003c\/td\u003e\n\u003ctd\u003eSSC50S\/D, SSC57S\/D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Network Protocol\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP control bus protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Architecture\u003c\/td\u003e\n\u003ctd\u003eSIL 3 configurable in dual-redundant setups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Features\u003c\/h3\u003e\n\u003cp\u003eThe SCP451-51 S1 processes continuous safety signals using high-speed Vnet\/IP communication channels. Integrated galvanic isolation barriers isolate internal microprocessors from field wiring ground loops and electrical voltage transients. The module continuously calculates cold junction compensation values and monitors 4-20 mA analog trip limits sent from remote safety I\/O modules, maintaining microsecond-level synchronization across dual-redundant processor pairs to eliminate single points of failure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What action occurs during a single-module replacement in a dual-redundant SSC50D Safety Control Unit?\u003c\/p\u003e\n\u003cp\u003eA: Technicians can extract a faulted SCP451-51 S1 module while the partner processor maintains continuous safety logic execution. Inserting the replacement module into the live rack initiates automated backplane memory synchronization, restoring redundant redundancy without interrupting field safety loops.\u003c\/p\u003e\n\u003cp\u003eQ: How do installer technicians verify cabinet grounding compliance for the SCP451-51 S1?\u003c\/p\u003e\n\u003cp\u003eA: Installation personnel must connect the rack earth lug directly to the main station ground bar using a dedicated copper strap. Measurement across the ground connection must show a path resistance of less than 1 Ohm to ensure effective shield drain currents and suppress noise on Vnet\/IP network lines.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eAlign the SCP451-51 S1 card edges with the guide tracks of the target SSC50S\/D or SSC57S\/D Safety Control Unit slot. Push the module firmly into the chassis until the rear backplane connectors seat completely, then tighten the upper and lower faceplate retaining screws to a torque of 0.5 Nm. Ensure all Vnet\/IP communication cables route through isolated wire ducts, maintaining at least 200 mm of physical distance from high-voltage power lines to prevent high-frequency noise coupling. Connect cabinet earth straps directly to the main protective earth bar with less than 1 Ohm total resistance.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67676882206819,"sku":"SCP451-51-S1","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/887_4b6349ba-1eab-4dc9-aebc-a2c02a8d31d7.jpg?v=1791616852"},{"product_id":"yokogawa-cp401-11-s1-plc-processor-module","title":"Yokogawa CP401-11 S1 PLC Processor Module","description":"\u003ch2\u003eYokogawa CP401-11 S1 PLC Processor Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa CP401-11 S1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP401\u003c\/strong\u003e PLC Processor Module, operates as a dedicated hardware component for control logic execution and system data processing within CENTUM distributed control system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP401-11 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.1 cm $\\times$ 10.3 cm $\\times$ 14.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eRefer to applicable hardware manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eControl logic execution and system data processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eControl Processing \u0026amp; System Architecture\u003c\/h3\u003e\n\u003cp\u003eConfigured for industrial automation tasks across CENTUM series platforms, the unit executes deterministic control algorithms and coordinates data exchange across field control stations. The hardware supports redundant CPU configurations to maintain operational availability in continuous process environments. Backplane communication velocity and internal diagnostics ensure synchronization across connected I\/O nodes without intermittent polling delays.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swapping in redundant configurations?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping depends on the specific field control station node design and firmware revision. Verify rack-level support in the system manual before replacing modules under power.\u003c\/p\u003e\n\u003cp\u003eQ: How is firmware compatibility managed during replacement?\u003c\/p\u003e\n\u003cp\u003eA: The replacement unit must match the exact system software revision and safety node version currently active in the CENTUM engineering station to prevent communication faults.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify Power State:\u003c\/strong\u003e Ensure the field control station rack is powered down or configured for safe module insertion according to system specifications. Verify success by checking that rack LED indicators are fully extinguished.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect Physical Slots:\u003c\/strong\u003e Align the module guides with the designated backplane slot slots, ensuring no bent pins or obstruction on the connector interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure Retention Latches:\u003c\/strong\u003e Push the module firmly into the backplane connector until the top and bottom locking mechanisms engage completely. Verify success by gently pulling on the module handle to confirm zero lateral play.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInitialize System:\u003c\/strong\u003e Restore power and monitor the front-panel status LEDs for normal self-test completion and communication synchronization with the primary controller.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67691420745827,"sku":"CP401-11 S1","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/925.jpg?v=1791853037"},{"product_id":"cp471-00-yokogawa-s1-controller-module","title":"CP471-00 Yokogawa S1 Controller Module","description":"\u003ch2\u003eYokogawa CP471-00 S1 Controller Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa CP471-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP471\u003c\/strong\u003e Processor Module, operates as a dedicated hardware component for control processing and execution of control functions within CENTUM VP distributed control system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP471-00 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 cm $\\times$ 20.3 cm $\\times$ 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eControl processing and execution of control functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Network Communication \u0026amp; Loop Control\u003c\/h3\u003e\n\u003cp\u003eConfigured for high-speed deterministic execution across CENTUM VP field control units, the unit manages 4-20 mA HART loop protocol parameters and communicates via internal backplane buses. Dual-redundant processor configurations ensure continuous data exchange across node interfaces without channel-to-channel crosstalk, while cold junction compensation and digital filtering stabilize analog feedback loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the dual-redundant configuration support online module replacement?\u003c\/p\u003e\n\u003cp\u003eA: Yes, online replacement is supported in approved dual-redundant setups, allowing physical swapping without interrupting active system control loops.\u003c\/p\u003e\n\u003cp\u003eQ: How is backplane communication synchronized between redundant CPU modules?\u003c\/p\u003e\n\u003cp\u003eA: Synchronization is maintained through dedicated high-speed bus couplers and redundant control links, ensuring zero-latency failover during active operational states.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify Power State:\u003c\/strong\u003e Ensure the target field control unit slot is powered down or configured for hot-insertion according to system specifications. Verify success by checking that local node status indicators are stable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect Physical Slots:\u003c\/strong\u003e Align the module card edges with the designated backplane guides, ensuring no pin distortion or physical obstruction on the edge connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure Retention Latches:\u003c\/strong\u003e Push the module firmly into the backplane connector until the top and bottom locking levers engage completely. Verify success by gently pulling on the front handle to confirm zero lateral movement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInitialize System:\u003c\/strong\u003e Restore power and monitor the front-panel status LEDs for normal self-test execution, processor synchronization, and communication lock with the engineering station.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67691451809891,"sku":"CP471","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/330._843205e1-fbc7-4bc1-a0d1-e0efc6575b14.jpg?v=1791853469"},{"product_id":"yokogawa-cp461-11-centum-processor-module","title":"Yokogawa CP461-11 CENTUM Processor Module","description":"\u003ch2\u003eYokogawa CP461-11 Processor Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa CP461-11\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP461\u003c\/strong\u003e Processor Module, operates as a dedicated hardware component for real-time control logic execution and data processing within CENTUM VP Field Control Units.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP461-11 (Style S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.1 cm $\\times$ 10.3 cm $\\times$ 14.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C (Refer to FCU hardware manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied via backplane bus from host Field Control Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003eCENTUM Distributed Control System (DCS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Hardware\u003c\/td\u003e\n\u003ctd\u003eSelected AFV30 and A2FV50 Field Control Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP control network bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eDual-redundant configuration capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eVnet\/IP Communication and Control Architecture\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with the Vnet\/IP deterministic control network to exchange process input\/output data and system diagnostic frames across distributed station nodes. Execution loops process field variables through internal firmware registers, maintaining synchronous execution cycles in dual-redundant configurations. Channel isolation boundaries mitigate common-mode electrical interference across backplane bus slots, while internal watchdogs monitor hardware health status to trigger bumpless transfer sequences upon detection of processor discrepancies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CP461-11 support hot-swapping during active process operation?\u003c\/p\u003e\n\u003cp\u003eA: Hot-insertion and removal depend strictly on the host Field Control Unit rack power design and redundant controller pairing status. Verify rack-specific power policies before module extraction.\u003c\/p\u003e\n\u003cp\u003eQ: How is controller redundancy synchronized between dual CP461-11 modules?\u003c\/p\u003e\n\u003cp\u003eA: Synchronization occurs via dedicated high-speed optical or electrical inter-module links built into the backplane enclosure, mirroring memory states and execution registers continuously.\u003c\/p\u003e\n\u003cp\u003eQ: What action is required when replacing a legacy CP461 revision with a Style S1 unit?\u003c\/p\u003e\n\u003cp\u003eA: Verify firmware version compatibility against the CENTUM engineering station database and ensure the hardware key matches the base slot mechanical configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure proper grounding of the host Field Control Unit chassis before sliding the module into the designated slot.\u003c\/li\u003e\n\u003cli\u003eHandle the printed circuit board using electrostatic discharge (ESD) wrist straps to protect sensitive internal microprocessors.\u003c\/li\u003e\n\u003cli\u003eAlign the module parallel to the card guide rails and apply firm, even pressure until the mechanical retaining latches engage fully.\u003c\/li\u003e\n\u003cli\u003eInspect the front panel status LED indicators after power-up to confirm normal CPU execution and communication bus linkage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67691469111395,"sku":"CP461-11","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/895._63497702-b4fe-41e5-a19c-b4e8f5f57454.jpg?v=1791853807"},{"product_id":"yokogawa-scp451-11-s1-prosafe-rs-processor-module","title":"Yokogawa SCP451-11 S1 ProSafe-RS Processor Module","description":"\u003ch2\u003eYokogawa SCP451-11 S1 ProSafe-RS Processor Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa SCP451-11 S1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSCP451-11\u003c\/strong\u003e ProSafe-RS Processor Module, operates as a dedicated hardware component for safety-oriented execution within ProSafe-RS Safety Instrumented System (SIS) platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSCP451-11 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard ProSafe-RS enclosure slot profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C (Refer to safety control unit documentation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied via backplane bus from host ProSafe-RS chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eMIPS R5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Memory\u003c\/td\u003e\n\u003ctd\u003e32 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eFlash memory for application programs; NVRAM for operating data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant Vnet\/IP (100 Mbps) and ESB bus interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSafety-Critical Control Execution and Redundancy\u003c\/h3\u003e\n\u003cp\u003eThe module coordinates safety logic execution through its internal MIPS R5000 architecture, feeding diagnostic frames across dual-redundant Vnet\/IP network channels. Channel-to-channel electrical isolation and built-in hardware watchdogs monitor system integrity continuously, maintaining fail-safe state execution pathways upon detection of critical faults. Furthermore, duplexed controller configurations synchronize memory states across dual modules to achieve high availability within emergency shutdown applications.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the SCP451-11 S1 module be replaced under live power conditions?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping depends entirely on the specific rack design and redundant system pairing status; verify safety controller power policies before extraction.\u003c\/p\u003e\n\u003cp\u003eQ: How do dual-redundant modules synchronize safety control logic execution?\u003c\/p\u003e\n\u003cp\u003eA: Synchronization occurs via dedicated high-speed backplane inter-module pathways, continuously cross-checking memory registers and hardware status bits.\u003c\/p\u003e\n\u003cp\u003eQ: What actions are required during firmware updates on safety processor cards?\u003c\/p\u003e\n\u003cp\u003eA: Updates must follow certified engineering workstation procedures to prevent safety integrity level (SIL) state interruptions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure proper grounding of the ProSafe-RS safety node chassis prior to module insertion.\u003c\/li\u003e\n\u003cli\u003eUtilize appropriate electrostatic discharge (ESD) wrist protection to shield microprocessors from static damage.\u003c\/li\u003e\n\u003cli\u003eAlign the module parallel to the card guide rails and apply steady pressure until internal connectors seat completely.\u003c\/li\u003e\n\u003cli\u003eInspect diagnostic LED indicators upon system startup to confirm valid CPU operation and redundant network link status.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67691496734819,"sku":"SCP451-11 S1","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/887_ecfb3c49-9ee7-4e47-81a9-d7caa030105e.jpg?v=1791854272"},{"product_id":"nfcp100-s00-yokogawa-stardom-fcn-cpu-module","title":"NFCP100-S00 Yokogawa STARDOM FCN CPU Module","description":"\u003ch2\u003eYokogawa NFCP100-S00 CPU Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa NFCP100-S00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNFCP100\u003c\/strong\u003e CPU Base Module, operates as a dedicated hardware component for sequence and analog control execution within STARDOM FCN Autonomous Controller platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFCP100-S00 (Style S3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg (1.70 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e65.8 mm $\\times$ 132 mm $\\times$ 145.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C (Refer to FCN system manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.8 A max at 5 V DC $\\pm$ 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eMMX-Pentium, 166 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Memory\u003c\/td\u003e\n\u003ctd\u003e128 MB with ECC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRetentive Memory\u003c\/td\u003e\n\u003ctd\u003e1 MB with ECC and battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e2 $\\times$ 10\/100 Mbps Ethernet (RJ45), 1 $\\times$ RS-232-C (9-pin D-sub)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and DCS Integration\u003c\/h3\u003e\n\u003cp\u003eThe module integrates seamlessly into distributed process control architectures by transmitting field data across dual Ethernet interfaces and supporting standard 4-20 mA HART loop protocol integrations through connected I\/O cards. Channel-to-channel isolation safeguards sensitive conversion circuits against common-mode electrical transients, while internal cold junction compensation (CJC) ensures precise thermocouple signal processing. Furthermore, deterministic network communication protocols maintain synchronous execution cycles across distributed FCN nodes without transmission jitter.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the RS-232-C serial port be utilized when the CPU modules are configured in a redundant pair?\u003c\/p\u003e\n\u003cp\u003eA: No, the serial interface is disabled on redundant CPU configurations to prevent arbitration conflicts on the communication bus.\u003c\/p\u003e\n\u003cp\u003eQ: How does the retentive memory retain data during sudden power losses?\u003c\/p\u003e\n\u003cp\u003eA: Retentive memory relies on a 2700 mAh lithium battery backup combined with ECC protection to preserve critical control variables safely.\u003c\/p\u003e\n\u003cp\u003eQ: What precautions are necessary during firmware flashing on the NFCP100-S00?\u003c\/p\u003e\n\u003cp\u003eA: Ensure uninterrupted power supply to the 5 V DC backplane and maintain network stability throughout the entire flash write cycle to prevent corruption.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the FCN rack power supply is switched off before inserting or extracting the CPU module from the 2-slot base chassis.\u003c\/li\u003e\n\u003cli\u003eGround your wrist properly using an ESD-safe strap to protect the internal MMX-Pentium processor from electrostatic discharge.\u003c\/li\u003e\n\u003cli\u003eSlide the module smoothly along the enclosure guide rails, then secure the top and bottom retaining screws to ensure proper backplane connector engagement.\u003c\/li\u003e\n\u003cli\u003eInspect the front panel LED indicators upon startup to verify normal CPU execution status and network link integrity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67691509284963,"sku":"NFCP100-S00","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/926.jpg?v=1791854543"},{"product_id":"yokogawa-cp701-s1-field-control-cpu-module","title":"Yokogawa CP701 S1 Field Control CPU Module","description":"\u003ch2\u003eYokogawa CP701 S1 Field Control CPU Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa CP701 S1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP701\u003c\/strong\u003e Field Control CPU Module, operates as a dedicated hardware component for real-time control logic execution and process data processing within CENTUM distributed control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP701 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e254 mm $\\times$ 51 mm $\\times$ 279 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C (Refer to FCS technical documentation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied via backplane rack from host FCS power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eR4300 MPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock Frequency\u003c\/td\u003e\n\u003ctd\u003e75 MHz internal, 25 MHz external\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Memory\u003c\/td\u003e\n\u003ctd\u003e8 MB with ECC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003eCENTUM CS Distributed Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with field instrumentation architectures by supporting 4-20 mA HART loop protocol integrations via connected input\/output cards. Channel-to-channel isolation boundaries safeguard low-level analog conversion circuits against common-mode electrical interference across backplane bus slots. Furthermore, internal cold junction compensation (CJC) processing blocks maintain measurement accuracy during thermocouple signal conditioning without introducing transmission drift.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CP701 S1 CPU module be hot-swapped during active loop execution?\u003c\/p\u003e\n\u003cp\u003eA: Hot-insertion and removal procedures depend strictly on the host Field Control Station backplane power design and redundant controller pairing status; verify rack policies prior to handling.\u003c\/p\u003e\n\u003cp\u003eQ: How does the memory handle runtime error detection?\u003c\/p\u003e\n\u003cp\u003eA: The 8 MB main memory incorporates error-correction code (ECC) hardware logic to detect and correct single-bit memory corruptions automatically during execution cycles.\u003c\/p\u003e\n\u003cp\u003eQ: What precautions are necessary when updating system software versions?\u003c\/p\u003e\n\u003cp\u003eA: Ensure complete firmware compatibility verification against the target CENTUM engineering station database before initiating memory flashing sequences.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower down the Field Control Station chassis entirely before inserting or extracting the CPU module from the designated base slot.\u003c\/li\u003e\n\u003cli\u003eGround your wrists using a certified electrostatic discharge (ESD) strap to protect sensitive microprocessors and memory components.\u003c\/li\u003e\n\u003cli\u003eAlign the module parallel to the card guide rails and apply steady, even pressure until the mechanical backplane connectors seat completely.\u003c\/li\u003e\n\u003cli\u003eVerify front-panel diagnostic status indicators upon system startup to confirm normal processor execution and communication bus linkage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67691522719843,"sku":"CP701 S1","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/927..jpg?v=1791854836"},{"product_id":"pw442-50-s2-yokogawa-centum-vp-power-supply-module","title":"PW442-50-S2 Yokogawa CENTUM VP Power Supply Module","description":"\u003ch2\u003eYokogawa PW442-50-S2 Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa PW442-50-S2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePW442-50\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for power distribution and conversion within CENTUM VP Distributed Control System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePW442-50-S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard CENTUM VP rack mounting profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C (Refer to system enclosure guidelines)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInput rating: 220-240 V AC, 50\/60 Hz; Output current: 0.7-4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Application\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP Distributed Control System (DCS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eDual-redundant configuration supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module stabilizes system distribution busses while supporting connected input\/output cards that drive 4-20 mA HART loop protocol instruments across the plant network. Comprehensive channel-to-channel isolation safeguards low-voltage internal logic circuits against hazardous transient spikes originating from primary AC power feeds. Additionally, internal cold junction compensation (CJC) circuits maintain thermal stability for associated field signal conditioners, preventing voltage drift during continuous high-load operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the PW442-50-S2 power supply module be replaced under active system power?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping depends entirely on the specific rack backplane design and whether a dual-redundant secondary module is actively carrying the load; verify cabinet policies beforehand.\u003c\/p\u003e\n\u003cp\u003eQ: How do dual-redundant power modules manage load sharing?\u003c\/p\u003e\n\u003cp\u003eA: Redundant units operate in parallel diode-OR configurations, balancing current draws automatically without interrupting backplane output voltages.\u003c\/p\u003e\n\u003cp\u003eQ: What precautions are necessary when wiring the AC input terminals?\u003c\/p\u003e\n\u003cp\u003eA: Ensure the primary AC supply is completely isolated upstream, and secure earth-ground connections firmly to the chassis grounding lug.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the primary 220-240 V AC power source is locked out and tagged out before handling the module.\u003c\/li\u003e\n\u003cli\u003eWear an ESD-compliant wrist strap to prevent static discharge damage to internal regulation components.\u003c\/li\u003e\n\u003cli\u003eSlide the module evenly along the designated enclosure guide slot until the rear power connectors engage fully with the backplane.\u003c\/li\u003e\n\u003cli\u003eCheck the front-panel status indicators after energizing the system to confirm proper AC input and DC output voltage regulation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67691550998627,"sku":"PW442-50","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/909.1_588151b7-0151-45fc-9797-722a1cc04dad.jpg?v=1791855320"},{"product_id":"yokogawa-s9681db-0-centum-digital-i-o-terminal-board","title":"Yokogawa S9681DB-0 CENTUM Digital I\/O Terminal Board","description":"\u003ch2\u003eYokogawa S9681DB-0 Digital I\/O Terminal Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa S9681DB-0\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eS9681DB\u003c\/strong\u003e Digital I\/O Terminal Board, operates as a dedicated hardware component for field wiring termination and signal interconnection within CENTUM VP and CS3000 distributed control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS9681DB-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 mm $\\times$ 142.5 mm $\\times$ 32.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 digital inputs (0 to 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 digital outputs (0 to 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOpto-coupler isolation for noise immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail or panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Loop Protocols\u003c\/h3\u003e\n\u003cp\u003eThe board interfaces directly with field discrete loops while supporting associated I\/O modules that manage 4-20 mA HART loop protocol integrations across the control network. Opto-coupler isolation barriers safeguard internal logic circuitry against severe ground loops and common-mode electrical transients originating from field cabling. Furthermore, integrated cold junction compensation (CJC) blocks handle temperature-dependent analog inputs seamlessly when paired with multi-function I\/O cards.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can terminal blocks on the S9681DB-0 be rewired while active loop power is applied?\u003c\/p\u003e\n\u003cp\u003eA: Field wiring modifications require upstream loop power isolation to prevent accidental short circuits or controller fault trips.\u003c\/p\u003e\n\u003cp\u003eQ: How does the opto-coupler isolation protect the connected I\/O cards?\u003c\/p\u003e\n\u003cp\u003eA: Optical isolation decouples high-voltage field transients physically from the low-voltage control backplane bus.\u003c\/p\u003e\n\u003cp\u003eQ: What precautions should be observed when mounting the board on a DIN rail?\u003c\/p\u003e\n\u003cp\u003eA: Ensure the metallic rail is grounded properly to maintain electromagnetic shielding and surge dissipation integrity across the cabinet assembly.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that all connected field power sources are locked out before servicing terminal block connections.\u003c\/li\u003e\n\u003cli\u003eSecure the board firmly onto a standard DIN rail or panel mounting surface using appropriate locking brackets.\u003c\/li\u003e\n\u003cli\u003eRoute low-level signal cables separately from high-voltage power conduits to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eInspect all terminal screw torque ratings to ensure secure mechanical contact and low-resistance signal transmission.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67691585273955,"sku":"S9681DB","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/912._69acbc6a-d8c2-4261-aa0e-f1c1236e0c7a.jpg?v=1791855850"},{"product_id":"yokogawa-akb331-m020-sdv541-prosafe-rs-signal-cable","title":"Yokogawa AKB331-M020\/SDV541 ProSafe-RS Signal Cable","description":"\u003ch2\u003eYOKOGAWA AKB331-M020\/SDV541 Signal Cable\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA AKB331-M020\/SDV541\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAKB331\u003c\/strong\u003e signal cable, operates as a dedicated hardware component for 50-pin digital output signal transmission between SDV541 modules and terminal boards within Yokogawa ProSafe-RS systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAKB331-M020\/SDV541\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e20 m length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive pass-through component (0 W active draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e50-pin high-density connector to 50-pin high-density connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Module\u003c\/td\u003e\n\u003ctd\u003eSDV541 Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eYokogawa ProSafe-RS \/ FIO System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Function\u003c\/td\u003e\n\u003ctd\u003eInter-cabinet digital output signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eDesigned to maintain rigorous electromagnetic compatibility in industrial control environments, the cable assembly incorporates dedicated shielding against high-frequency electromagnetic interference. The physical architecture preserves channel isolation parameters across the 20-meter span, ensuring deterministic signal delivery from the ProSafe-RS digital output modules to field terminal boards without voltage degradation or cross-talk interference.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum allowable bend radius during physical installation of this 50-pin cable?\u003c\/p\u003e\n\u003cp\u003eA: The cable assembly must maintain a minimum bend radius complying with standard industrial multi-core wiring specifications to prevent mechanical stress on the high-density internal conductors and connector pins.\u003c\/p\u003e\n\u003cp\u003eQ: Does this cable supply active power to the connected terminal boards?\u003c\/p\u003e\n\u003cp\u003eA: No. The assembly functions entirely as a passive signal transmission path for digital outputs and contains no active amplification or power supply circuitry.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize the associated Yokogawa ProSafe-RS controller cabinet and connected terminal boards prior to physical handling.\u003c\/li\u003e\n\u003cli\u003eInspect both 50-pin high-density connectors for bent pins or debris contamination before mating.\u003c\/li\u003e\n\u003cli\u003eAlign the connector keyways carefully and secure the fastening screws to specified torque limits to prevent accidental disconnection from vibration.\u003c\/li\u003e\n\u003cli\u003eRoute the 20-meter cable through dedicated signal wire trays, maintaining physical separation from high-voltage power lines to mitigate electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eVerify continuity and correct pin-to-pin mapping across the channel loop before restoring system power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67700165869667,"sku":"AKB331-M020\/SDV541","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/928..jpg?v=1791943490"}],"url":"https:\/\/www.autocontrolglobal.com\/collections\/yokogawa-cpu-module.oembed?page=3","provider":"AutoControl Global","version":"1.0","type":"link"}