{"product_id":"ge-fanuc-ic695alg626-hart-module-new-original-stock","title":"GE Fanuc IC695ALG626 HART Module | New \u0026 Original Stock","description":"\u003ch2\u003eGE Fanuc IC695ALG626 Analog Input Module with HART\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC695ALG626-CA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC695ALG626\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for converting analog signals into digital values within PACSystems RX3i platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695ALG626-CA \/ IC695ALG626\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc (Emerson Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg (0.63 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PACSystems RX3i single-slot module dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.23 W (600 mA @ 3.3 VDC, 450 mA @ 5 VDC backplane draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eNon-isolated analog input module with HART communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 single-ended or 8 differential input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Ranges\u003c\/td\u003e\n\u003ctd\u003e+\/-10 VDC, 0-10 VDC, +\/-5 VDC, 0-5 VDC, 1-5 VDC, +\/-50 mV, +\/-150 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Ranges\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-20 mA, +\/-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eHART Version 5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Resolution\u003c\/td\u003e\n\u003ctd\u003e24-bit Analog-to-Digital Converter (ADC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Data Format\u003c\/td\u003e\n\u003ctd\u003eIEEE 32-bit floating point or 16-bit integer in a 32-bit field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurable Filters\u003c\/td\u003e\n\u003ctd\u003e8 Hz, 12 Hz, 16 Hz, 40 Hz, 200 Hz, 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Overvoltage\u003c\/td\u003e\n\u003ctd\u003e+\/-60 VDC continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Overcurrent\u003c\/td\u003e\n\u003ctd\u003e+\/-28 mA continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003eVoltage: \u0026gt;100 kOhm; Current: 249 Ohm +\/-1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eAutocalibration executed automatically during power-up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen Circuit Fault Time\u003c\/td\u003e\n\u003ctd\u003e1 second maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC695ALG626\u003c\/strong\u003e incorporates an integrated HART modem per channel to process digital telemetry superimposed onto standard 4-20 mA HART loop protocol lines. The 24-bit analog-to-digital converter transforms continuous current and voltage waveforms into formatted data registers without disrupting background digital parameter scanning. The hardware utilizes global optocouplers providing 250 VDC channel-to-PLC backplane isolation, though individual paths remain non-isolated from adjacent channels on the common field terminal. Signal processing frequencies are restricted by internal hardware filters configurable down to 8 Hz to eliminate high-frequency cross-talk and industrial line harmonics.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the onboard current loop resistance managed when configuring a channel for current inputs?\u003c\/strong\u003e A: When a channel terminal is configured for current sensing, the module switches in an internal precision 249 Ohm (+\/-1%) shunt resistor. Field wiring must ensure that overcurrent conditions do not exceed the +\/-28 mA continuous limit to prevent thermal breakdown of this internal sensing element.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module require manual software calibration routines to maintain its 24-bit resolution accuracy?\u003c\/strong\u003e A: No. The hardware executes an autocalibration sequence automatically upon every power-up cycle. Internal reference voltages are measured against the ADC thresholds to adjust zero and gain offset constants, ensuring stable signal conversion across the 0 to 60 deg C operating boundary.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Assembly and Power Lockout:\u003c\/strong\u003e Completely isolate the RX3i Universal Backplane power supply and any connected field loops before engaging or disengaging the front terminal connector block to avoid active channel arcing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding and Differential Routing:\u003c\/strong\u003e Route all 4-20 mA and low-voltage signal pairs using twisted, shielded instrumentation wire. Terminate the outer copper shield braid exclusively at the central enclosure earth ground bus bar to minimize stray ambient electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Circuit Fault Suppression:\u003c\/strong\u003e For any input channels left unpopulated in the final system deployment, configure the respective software registers to disabled. This action suppresses the native 1-second open circuit detection alarm and prevents false hardware alerts from populating the CPU fault table.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44258827206755,"sku":"IC695ALG626-CA","price":420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/29_033a8402-6424-44f0-9e7f-84d7a6681fc7.jpg?v=1781488468","url":"https:\/\/www.autocontrolglobal.com\/de\/products\/ge-fanuc-ic695alg626-hart-module-new-original-stock","provider":"AutoControl Global","version":"1.0","type":"link"}