{"product_id":"he693thm884m-ge-fanuc-thermocouple-input-series-90-30-module","title":"HE693THM884M | GE Fanuc Thermocouple Input | Series 90-30 Module","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc HE693THM884M Thermocouple Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc HE693THM884M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an advanced thermocouple input module designed for precision temperature measurement and control. Part of the Series 90-30 PLC family, this module is ideal for a wide range of industrial applications, including metallurgy, chemical processing, petroleum, and general automation. Featuring support for a broad variety of thermocouples and RTDs, it offers exceptional accuracy, robust diagnostics, and integration flexibility, making it perfect for applications requiring high-precision temperature monitoring.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e: HE693THM884M\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Thermocouple\/RTD Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 100 mA @ 5 VDC (Typical), 300 mA for full operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.45 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 120 × 40 × 150 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRack Form Factor\u003c\/strong\u003e: Series 90-30 PLC module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Points Required\u003c\/strong\u003e: 8AI, 8AQ, 16I\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature \u0026amp; Measurement Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e: 8 thermocouple input channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Sensor Types\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermocouples\u003c\/strong\u003e: J, K, T, E, R, S, B, N\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRTDs\u003c\/strong\u003e: Supported depending on configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType J\u003c\/strong\u003e: –200 °C to +760 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType K\u003c\/strong\u003e: –270 °C to +1372 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOther types\u003c\/strong\u003e: –200 °C to +1800 °C \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e: 0.1 °C increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±0.1% of span (high precision)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA\/D Conversion\u003c\/strong\u003e: High-precision A\/D for stable readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScan Rate\u003c\/strong\u003e: Optimized for multi-channel use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics \u0026amp; Fault Detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOpen-Circuit Detection\u003c\/strong\u003e: Registers sensor failure by driving input register to maximum value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault Indication\u003c\/strong\u003e: Available via PLC registers for easy diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: –40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What thermocouple types does the HE693THM884M support?\u003c\/strong\u003e\u003cbr\u003eThe module supports multiple thermocouple types including J, K, T, E, R, S, B, and N, offering flexibility for various industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can this module handle RTDs?\u003c\/strong\u003e\u003cbr\u003eYes, the HE693THM884M supports RTDs, though compatibility depends on the configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the scan rate of the HE693THM884M?\u003c\/strong\u003e\u003cbr\u003eThe module offers an optimized scan rate for fast, accurate temperature readings across multiple channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is there any fault detection feature in the HE693THM884M?\u003c\/strong\u003e\u003cbr\u003eYes, the module includes open-circuit detection, which drives the input register to its maximum value if a thermocouple fails.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What is the power consumption of the HE693THM884M?\u003c\/strong\u003e\u003cbr\u003eThe module typically consumes 100 mA at 5 VDC, with a full operational consumption of around 300 mA.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43876678238307,"sku":"HE693THM884M","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/155._b3fcec66-caf0-4a4f-bc57-eb5df3ede8e9.jpg?v=1765158222","url":"https:\/\/www.autocontrolglobal.com\/de\/products\/he693thm884m-ge-fanuc-thermocouple-input-series-90-30-module","provider":"AutoControl Global","version":"1.0","type":"link"}