  • Manufacturer: Honeywell

  • Part Number: KFD2-SCD2-EX1.LK

  • Condition:New with Original Package

  • Product Type: Pepperl+Fuchs HART-Compatible Current Driver

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Description

The Pepperl+Fuchs KFD2-SCD2-EX1.LK is a 1-channel SMART current driver and isolated barrier, engineered for intrinsically safe analog output applications in hazardous areas. It delivers a precise 4–20 mA current output to drive SMART I/P converters, electrical valves, and positioners, ensuring reliable operation in critical process automation environments.

This module supports HART-IP communication, allowing bi-directional digital signals to be superimposed on the analog output. Moreover, it features line fault detection (LFD), test sockets on terminals, and galvanic isolation to guarantee both safety and accuracy. Its compact DIN rail design simplifies integration into control panels, while SIL 2 (SC 3) certification confirms compliance with IEC/EN 61508 standards.

Technical Specifications

Specification Details
Model Number KFD2-SCD2-EX1.LK
Function SMART Current Driver / Isolated Barrier
Channels 1-channel
Input Type Analog signal from control system
Output Type Current output (4–20 mA) to hazardous-area devices
Load Resistance Up to 650 Ω
Power Supply 24 V DC via Power Rail
HART Communication Supported (bi-directional)
Line Fault Detection Yes (open/short circuit monitoring)
Accuracy ±0.1%
Isolation Galvanic isolation between input, output, and power
Mounting Type DIN rail
Operating Temperature –20°C to +60°C
Safety Compliance SIL 2 (SC 3) per IEC/EN 61508
Certifications ATEX, IECEx, FM, CSA
Dimensions (W × H × D) 20 mm × 124 mm × 115 mm
Weight 0.15 kg

FAQ

Q1: What type of devices can KFD2-SCD2-EX1.LK drive?
It drives SMART I/P converters, electrical valves, and positioners in hazardous areas.

Q2: Does it support digital communication?
Yes, it supports HART-IP for bi-directional digital signals.

Q3: What is the safety certification of this module?
It is certified SIL 2 (SC 3) according to IEC/EN 61508 standards.

Q4: How is it installed?
The module is DIN rail mountable and includes terminals with test sockets.

Q5: Does it include fault detection?
Yes, line fault detection (LFD) monitors open and short circuits for safety.

 