{"product_id":"di3301s2-triconex-tmr-input-module-100-original-stock","title":"DI3301S2 Triconex TMR Input Module - 100% Original Stock","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTriconex DI3301S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-integrity interface between discrete field devices and the Triconex Triple Modular Redundancy (TMR) controller. This module monitors critical safety inputs—including emergency stop buttons, pressure switches, and flame detectors—and conditions these signals for the safety logic solver. Utilizing a fault-tolerant architecture, the DI3301S2 ensures that no single internal failure results in a loss of the safety function or a nuisance trip. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, specifically engineered for high-availability environments in the oil \u0026amp; gas and chemical sectors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDI3301S2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTriconex (Schneider Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafety Digital Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDry contacts, relay contacts, discrete signals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Input Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eArchitecture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTriple Modular Redundancy (TMR)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh galvanic isolation (Channel-to-Backplane\/Ground)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 C to +85 C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard DIN rail compatible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.42 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDiagnostics\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated LEDs for channel status and fault detection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTriple Modular Redundancy (TMR):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe DI3301S2 processes each input signal through three independent internal paths. Hardware voting ensures the system reaches the correct safety decision even if one circuit leg encounters an error, maintaining 24\/7 operational continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Temperature Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for rugged environments, the module operates reliably from -40 C to +85 C. This thermal tolerance makes it ideal for remote instrument enclosures (RIEs) in locations with extreme seasonal fluctuations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in Predictive Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced internal diagnostics continuously monitor the health of the input circuitry. If the module detects a fault, it alerts the operator via TriStation 1131 and front-panel LEDs while the redundant legs continue to manage the safety loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features superior galvanic isolation to block electrical noise and protect the controller backplane from field-side surges. This ensures clean, deterministic signal acquisition from remote field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swappable Functionality:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintenance teams replace the DI3301S2 without powering down the rack or bypassing the safety function. This \"online replacement\" capability significantly lowers the Mean Time to Repair (MTTR) and prevents production loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the DI3301S2 support 120V inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe DI3301S2 is optimized for 24 VDC discrete signals (dry contacts). For 120V input requirements, you should utilize an interposing relay or a dedicated high-voltage input module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"S2\" revision in the model number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"S2\" designates a specific hardware revision or communication variant. Always verify that your current Triconex system firmware and TriStation project configuration support the DI3301S2 version for seamless integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module distinguish between a \"Closed\" contact and a wiring fault?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module performs continuous circuit checks. If it detects a value outside the normal discrete voltage thresholds, it identifies it as a fault rather than a valid signal state change, preventing an incorrect safety action.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module certified for SIL 3 applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The TMR architecture of the Triconex platform, including the DI3301S2, is TUV certified for use in Safety Integrity Level 3 (SIL 3) applications, providing the highest standard of risk reduction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43783643824227,"sku":"DI3301S2","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/39_f4523c19-f580-43f6-9666-8732d64236fe.jpg?v=1760684860","url":"https:\/\/www.autocontrolglobal.com\/fa\/products\/di3301s2-triconex-tmr-input-module-100-original-stock","provider":"AutoControl Global","version":"1.0","type":"link"}