{"product_id":"ge-469-p5-hi-a20-t-high-voltage-control-power-module","title":"GE 469-P5-HI-A20-T High-Voltage Control Power Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin 469-P5-HI-A20-T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a comprehensive protection, control, and monitoring solution for medium to large-scale industrial motors. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal unit integrates advanced thermal modeling and digital signal processing to safeguard induction and synchronous motors. By monitoring critical electrical and thermal parameters, the 469-P5-HI-A20-T prevents costly motor failures and optimizes maintenance schedules in power generation, mining, and heavy manufacturing sectors. It serves as the primary intelligence for high-value motor assets, ensuring continuous operation under complex industrial loads.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e469-P5-HI-A20-T\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Multilin \/ GE Vernova\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhase CT Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 A Secondaries\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90–300 VDC or 70–265 VAC @ 48–62 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4–20 mA (Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Modes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload, Short Circuit, Ground Fault, Phase Loss, Thermal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RTU\/TCP, DNP3, IEC 61850\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS485, Ethernet, USB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Panel-Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSophisticated Thermal Modeling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 469-P5-HI-A20-T utilizes an advanced thermal model that accounts for motor heating due to overload, unbalanced current, and stator cooling. This precise calculation allows the motor to operate at its maximum safe capacity without risking insulation damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Power Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"HI\" control power designation enables the relay to operate across a wide voltage range (90–300 VDC or 70–265 VAC). This flexibility ensures compatibility with diverse substation battery banks and industrial AC mains, simplifying global deployment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnified Communication Stack:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis relay supports multiple high-level protocols including IEC 61850 and DNP3. These interfaces allow the 469 to integrate seamlessly into modern SCADA and DCS environments, providing operators with real-time data streaming for predictive analytics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Environmental Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for the harshest conditions, the module maintains operational accuracy from –40°C to +70°C. The robust hardware resists high-vibration and electromagnetic interference (EMI) levels typically found near large motor starters and variable frequency drives (VFDs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Diagnostic Logging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated LCD and historical event logs track motor trips, starts, and operational hours. Maintenance teams use this data to perform root-cause analysis on motor faults, significantly reducing the Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the significance of the \"P5\" and \"A20\" codes in this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"P5\" indicates 5A Phase CT secondaries, making it compatible with standard industrial current transformers. The \"A20\" designates the inclusion of 4–20 mA analog outputs, which allows the relay to transmit motor parameters to external PLC or DCS analog inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this relay protect synchronous motors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The Multilin 469 series specifically supports both induction and synchronous motors. For synchronous applications, it monitors field excitation and pull-out conditions to ensure synchronized operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the \"T\" suffix affect the device?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"T\" typically indicates enhanced features or specific environmental testing\/options within the 469 family, such as enhanced communication or specific terminal configurations. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal unit meets all standard Multilin 469 high-performance benchmarks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the relay support remote monitoring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAbsolutely. Through the Ethernet port or RS485 interface, you can access all motor data, trip history, and diagnostic values remotely using GE’s EnerVista software or third-party SCADA systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43820579258467,"sku":"469-P5-HI-A20-T","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/118_38ec0de3-1d3f-48bd-be37-10ddfe6c25a9.jpg?v=1762409786","url":"https:\/\/www.autocontrolglobal.com\/fa\/products\/ge-469-p5-hi-a20-t-high-voltage-control-power-module","provider":"AutoControl Global","version":"1.0","type":"link"}