{"product_id":"triconex-9100-main-processor-module-32-bit-mpm","title":"Triconex 9100 Main Processor Module | 32-Bit MPM","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTriconex 9100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the primary intelligence center for the Tricon Safety Instrumented System (SIS). This 32-bit Main Processor Module (MPM) executes complex safety logic, manages high-speed I\/O coordination, and performs continuous system-wide diagnostics. It utilizes a sophisticated Triple Modular Redundancy (TMR) architecture to provide exhaustive fault tolerance. We provide this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your safety loops meet the rigorous demands of offshore, refinery, and chemical processing environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTriconex (Schneider Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMain Processor Module (MPM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eArchitecture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTriple Modular Redundancy (TMR)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProcessor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32-bit High-Performance Microprocessor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 MB RAM \/ 16 MB Flash\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoting Logic\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo-out-of-three (2oo3) hardware voting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInter-Module Link\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed TriBus Communication\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 C to +55 C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19.9 cm x 23.3 cm x 6.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTUV Certified for SIL 3 Applications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTriple Modular Redundancy (TMR):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThree independent 9100 modules work in parallel. If one processor fails, the remaining two maintain uninterrupted control, eliminating single points of failure in safety-critical interlocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware-Implemented 2oo3 Voting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe TriBus interface synchronizes data across all three processors. The hardware performs two-out-of-three voting on every scan, ensuring the system detects and bypasses any internal computational errors without tripping the process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Logic Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 32-bit microprocessor handles large-scale safety programs with minimal scan times. This speed proves essential for high-pressure emergency shutdown (ESD) and fire and gas (F\u0026amp;G) detection where milliseconds matter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Self-Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 9100 module constantly monitors its own internal health and the integrity of the I\/O bus. It pinpoints faults to the specific channel or module, allowing for online replacement without shutting down the plant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Memory Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith 16 MB of Flash memory and 8 MB of RAM, the module stores complex sequence-of-events (SOE) data and logic files securely, ensuring data retention even during power loss or system resets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the Triconex 9100 be replaced while the system is running?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Because the Tricon system utilizes TMR architecture, you can hot-swap a single 9100 MPM while the other two processors maintain active control of the process. This prevents costly downtime during maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module come in its original factory packaging?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. We supply the Triconex 9100 in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition, sealed in its original Schneider Electric\/Triconex industrial packaging to guarantee authenticity and performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the typical lifespan of the 9100 MPM in a refinery environment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTriconex engineered the 9100 for high-availability industrial service. When operated within specified temperature ranges (0-55 C), these modules provide years of reliable service in safety-critical 24\/7 operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich communication protocols does the 9100 support for SCADA integration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 9100 communicates via the Tricon controller's communication modules, supporting Modbus (RTU\/TCP), OPC, and Ethernet\/IP for seamless data sharing with your DCS or HM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43783621214307,"sku":"9100","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/28_3b345195-2fb3-4ea5-a42a-a3e7f7fa6ab6.jpg?v=1760683560","url":"https:\/\/www.autocontrolglobal.com\/hu\/products\/triconex-9100-main-processor-module-32-bit-mpm","provider":"AutoControl Global","version":"1.0","type":"link"}