{"product_id":"8810-hi-tx-ge-safety-analog-input-module-4-20-ma-for-hazardous-location","title":"8810-HI-TX | GE Safety Analog Input Module | 4–20 mA for Hazardous Location","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE 8810-HI-TX Safety Analog Input Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an advanced module designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehazardous area process automation\u003c\/strong\u003e. It provides precise, reliable analog input acquisition for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etransmitters and sensors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein industries such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoil \u0026amp; gas\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epetrochemical\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewater treatment\u003c\/strong\u003e. With\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 isolated input channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand support for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART communication\u003c\/strong\u003e, this module ensures safe, efficient operation in critical environments, meeting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 2 safety standards\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis module features a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA nominal signal range\u003c\/strong\u003e, offering\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-bit resolution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor accurate measurement and a fast\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e25 ms update speed\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eper channel.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLine fault detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor short and open circuits enhances system reliability, while\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures compatibility with smart transmitters for enhanced diagnostics and status reporting.\u003c\/p\u003e\n\u003cp\u003eDesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eClass I, Division 2 hazardous locations\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8810-HI-TX\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an ideal choice for industries that require robust, SIL 2-compliant solutions for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esafety instrumented systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e8 single-ended analog input channels\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e: 4–20 mA nominal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFull Signal Range\u003c\/strong\u003e: 0.25–24 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupports\u003c\/strong\u003e: 2-, 3-, or 4-wire transmitters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eResolution \u0026amp; Speed\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-bit resolution\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpdate speed\u003c\/strong\u003e: 25 ms per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHART Update\u003c\/strong\u003e: 0.75 s per point\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy \u0026amp; Repeatability\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy at 25°C\u003c\/strong\u003e: ±0.1% of span\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e: 0.05% of span\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Coefficient\u003c\/strong\u003e: 38 ppm\/°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLine Fault Detection\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShort Circuit Current\u003c\/strong\u003e: 23.5 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOpen Circuit Current\u003c\/strong\u003e: \u0026lt;0.5 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage (@20 mA)\u003c\/strong\u003e: ≥10.2 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMax Output Current\u003c\/strong\u003e: 28 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHART Capabilities\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePass-through communication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAcquisition and status reporting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData format\u003c\/strong\u003e: IEEE754 floating point\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Power\u003c\/strong\u003e: 24 VDC from 8914-PSAC power supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e: 70 mA (system), 350 mA (field)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: –40°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: –40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e: 5–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Location\u003c\/strong\u003e: Class I, Division 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the purpose of the GE 8810-HI-TX module?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE 8810-HI-TX\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehazardous area process automation\u003c\/strong\u003e, enabling reliable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog input acquisition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom transmitters and sensors, while meeting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. How many input channels does the module support?\u003c\/strong\u003e\u003cbr\u003eIt supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 isolated analog input channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA nominal signal range\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What is the accuracy of the module?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eaccuracy\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±0.1% of span\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eat\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e25°C\u003c\/strong\u003e, providing high-precision measurements for critical processes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Is the module certified for use in hazardous locations?\u003c\/strong\u003e\u003cbr\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8810-HI-TX\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis certified for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eClass I, Division 2 hazardous locations\u003c\/strong\u003e, making it suitable for use in dangerous environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. What industries can benefit from the GE 8810-HI-TX module?\u003c\/strong\u003e\u003cbr\u003eIt is ideal for industries such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoil \u0026amp; gas\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epetrochemical\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewater treatment\u003c\/strong\u003e, all of which require\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecompliance for safety.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43876762222691,"sku":"8810-HI-TX","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/215._c08f716f-9e3e-4df7-81ef-d5ccb7d6ff5e.jpg?v=1765165383","url":"https:\/\/www.autocontrolglobal.com\/id\/products\/8810-hi-tx-ge-safety-analog-input-module-4-20-ma-for-hazardous-location","provider":"AutoControl Global","version":"1.0","type":"link"}