{"product_id":"fc-tsgash-1624p-honeywell-safety-manager-fta-module","title":"FC-TSGASH-1624P Modul FTA Manajer Keamanan Honeywell","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-TSGASH-1624P\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized Field Termination Assembly (FTA) for the Honeywell Safety Manager architecture. This module facilitates the critical interface between field-level gas and flame detectors and the Safety Instrumented System (SIS). It manages 16 independent analog input channels, converting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0–20 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efield signals into\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0–4 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignals for seamless processing by\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSAI-1620M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules. We supply this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring uncompromising integrity for mission-critical safety loops in hazardous industrial zones.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-TSGASH-1624P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell Safety Manager \/ SAI-1620M\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Analog Input Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–20 mA (Field) to 0–4 VDC (Internal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHART (Highway Addressable Remote Transducer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–20°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e261 mm × 194 mm × 52 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail or Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, COO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated HART Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC-TSGASH-1624P supports the HART protocol, allowing maintenance teams to access advanced device diagnostics and configuration data without interrupting the safety signal. This enables proactive sensor calibration and health monitoring for critical flame and gas detection loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Signal Conversion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe assembly utilizes high-accuracy circuitry to convert current-based field signals into voltage-based internal signals. This linear conversion maintains the fidelity of the raw data, ensuring the Safety Manager initiates emergency shutdowns or alarms based on exact threshold values.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Safety Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy consolidating 16 channels into a single 261mm footprint, this FTA optimizes cabinet space. This density reduces the overall hardware requirements for large-scale refineries and offshore platforms where space is at a premium.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Environmental Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for the rigors of petrochemical and power generation facilities, the module operates reliably across a wide temperature range. The design mitigates the risks of electrical noise and signal drift often found in high-interference industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhich Honeywell safety modules are compatible with the FC-TSGASH-1624P?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis FTA interfaces directly with Honeywell\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSAI-1620M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSafety Analog Input modules. It scales the field signals specifically to match the 0–4 VDC input requirements of the SAI-1620M hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this assembly support non-HART sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While it provides a transparent pass-through for HART data, it functions perfectly with standard 0–20 mA analog sensors that do not utilize digital communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary applications for this specific FTA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEngineers typically deploy the FC-TSGASH-1624P in Gas and Flame Detection Systems (FGS). It monitors high-stakes environments where rapid detection of combustible or toxic gases is mandatory for personnel safety and asset protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit refurbished or new?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee that every FC-TSGASH-1624P we ship is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original factory stock\u003c\/strong\u003e. We do not supply refurbished or used parts for safety-critical applications.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43796426719331,"sku":"FC-TSGASH-1624P","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/586.jpg?v=1761644124","url":"https:\/\/www.autocontrolglobal.com\/id\/products\/fc-tsgash-1624p-honeywell-safety-manager-fta-module","provider":"AutoControl Global","version":"1.0","type":"link"}