{"product_id":"8400-triconex-controller-module-for-tmr-sis-platforms","title":"8400 | Triconex Controller Module for TMR SIS Platforms","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Triconex 8400 is the central processor module for Triconex Safety Instrumented Systems (SIS).\u003cbr\u003eIt executes all safety logic and coordinates I\/O modules in mission-critical industrial environments.\u003cbr\u003eMoreover, the module features Triple Modular Redundancy (TMR) to ensure continuous operation without single-point failures.\u003cbr\u003eIt is engineered for high-hazard industries, providing safe shutdown, fire \u0026amp; gas protection, and high-integrity pressure protection.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMain Processor \/ Controller Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTriconex 8400\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSchneider Electric (Triconex brand)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTriconex SIS (Tricon, Trident, Tri-GP platforms)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArchitecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTriple Modular Redundancy (TMR)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32-bit high-performance CPU with redundant execution paths\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 MB RAM, 8 MB Flash (expandable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgram Storage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNon-volatile memory for safety logic programs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in self-diagnostics, watchdog timers, voting logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Integrity Level:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSIL 3 compliant (IEC 61508 certified)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUL, CE, ATEX, IECEx\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEthernet (10\/100 Mbps), RS-232\/RS-485, Modbus TCP\/IP, OPC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSequence of Events (SOE):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTime-stamped event logging, 1 ms resolution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–20 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5–95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (H × W × D):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApprox. 187 × 114 × 40 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 2.0 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the primary function of the Triconex 8400?\u003c\/strong\u003e\u003cbr\u003eIt serves as the central CPU, executing safety logic and coordinating I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is the 8400 SIL certified?\u003c\/strong\u003e\u003cbr\u003eYes, it is SIL 3 certified according to IEC 61508 standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What communication protocols are supported?\u003c\/strong\u003e\u003cbr\u003eIt supports Ethernet, Modbus TCP\/IP, OPC, and Triconex peer-to-peer protocols.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How does the 8400 ensure fault tolerance?\u003c\/strong\u003e\u003cbr\u003eThrough Triple Modular Redundancy (TMR) with redundant execution paths and voting logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What industries use this module?\u003c\/strong\u003e\u003cbr\u003eChemical, petrochemical, oil \u0026amp; gas, power generation, and high-hazard industrial facilities.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":43894904881251,"sku":"8400","price":260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/23.1_ae767225-161b-4fb9-811f-a537d8745ba3.jpg?v=1765938216","url":"https:\/\/www.autocontrolglobal.com\/it\/products\/8400-triconex-controller-module-for-tmr-sis-platforms","provider":"AutoControl Global","version":"1.0","type":"link"}