{"product_id":"aat141-s50-s2-yokogawa-centum-vp-tc-mv-input-module","title":"Modulo di ingresso TC\/mV Yokogawa CENTUM VP AAT141-S50 S2","description":"\u003ch2\u003eModulo di ingresso TC\/mV Yokogawa AAT141-S50 S2\u003c\/h2\u003e\n\u003cp\u003eConfigurato per l'acquisizione precisa dei segnali e la conversione digitale nei circuiti di controllo DCS, lo \u003cstrong\u003eYokogawa AAT141-S50 S2\u003c\/strong\u003e, catalogato anche come modulo di ingresso TC\/mV \u003cstrong\u003eAAT141\u003c\/strong\u003e, consente il collegamento diretto fisico\/elettrico. Gestisce 16 canali isolati che accettano direttamente ingressi da termocoppie e segnali in millivolt provenienti dai sensori di campo.\u003c\/p\u003e\n\u003ch3\u003eAnalisi del suffisso e matrice dei modelli\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCodice suffisso\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescrizione\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDettagli tecnici\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAAT141\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModello base\u003c\/td\u003e\n\u003ctd\u003eModulo di ingresso per termocoppie e millivolt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTipo\u003c\/td\u003e\n\u003ctd\u003eTipo standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProtezione antideflagrante\u003c\/td\u003e\n\u003ctd\u003eSenza protezione antideflagrante\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTipo base\u003c\/td\u003e\n\u003ctd\u003eArchitettura standard di elaborazione di base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRevisione\u003c\/td\u003e\n\u003ctd\u003eRevisione del sistema \/ design dei circuiti aggiornato\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecifiche hardware\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecifiche\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModello\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAAT141-S50 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigine\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGiappone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensioni\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 cm x 13 cm x 15 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura di esercizio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eda 0 a 55 gradi C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumo energetico\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 mA (5 VCC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumero di canali\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (isolati)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTipi di segnali di ingresso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTermocoppia (J, K, E, B, R, S, T, N), millivolt (da -100 a +150 mV, da -20 a +80 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistenza di ingresso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 M ohm o superiore (alimentazione ON\/OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensione di tenuta\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 VCA tra ingresso e sistema per 1 minuto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrecisione di misura\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTC: +\/-30 uV; mV: +\/-80 uV (intervallo da -100 a +150 mV), +\/-30 uV (intervallo da -20 a +80 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntervallo di aggiornamento dei dati\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 secondo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompensazione del giunto di riferimento\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-1 grado C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong deriva termica\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-80 uV\/10 gradi C (mV), +\/-30 uV\/10 gradi C (TC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCollegamento del cablaggio esterno\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMorsetto a pressione, cavo con connettore MIL, cavo dedicato (KS1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCompensazione del giunto freddo e isolamento del segnale\u003c\/h3\u003e\n\u003cp\u003eL'AAT141-S50 S2 integra un isolamento galvanico tra canale e sistema, con tenuta nominale di 1500 VCA, per impedire che il rumore dei loop di massa comprometta i segnali a bassa tensione in millivolt. L'hardware include circuiti interni di compensazione del giunto freddo (CJC), calibrati per fornire offset di riferimento accurati entro +\/-1 grado C. I singoli canali supportano la parametrizzazione software indipendente per le curve linearizzate delle termocoppie (tipi standard JIS\/IEC J, K, E, B, R, S, T, N) o per gli intervalli in millivolt (da -100 a +150 mV e da -20 a +80 mV), insieme a una routine configurabile di rilevamento della bruciatura del sensore a 60 secondi.\u003c\/p\u003e\n\u003ch3\u003eDomande frequenti\u003c\/h3\u003e\n\u003cp\u003eD: Come gestisce il modulo la rottura del cavo del sensore su un canale per termocoppia?\u003c\/p\u003e\n\u003cp\u003eR: Il modulo esegue una sequenza configurabile di rilevamento della bruciatura. I tecnici impostano il comportamento in caso di bruciatura su UP (fuori scala alto) o DOWN (fuori scala basso) entro 60 secondi dal rilevamento del circuito aperto.\u003c\/p\u003e\n\u003cp\u003eD: È possibile configurare canali con tipi di sensore diversi sullo stesso modulo?\u003c\/p\u003e\n\u003cp\u003eR: Sì, ciascuno dei 16 canali consente di impostare individualmente i tipi di termocoppia o gli intervalli in millivolt senza influire sull'isolamento o sulla risoluzione del segnale dei canali adiacenti.\u003c\/p\u003e\n\u003ch3\u003eLinee guida per l'installazione sul campo\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSchermatura e messa a terra:\u003c\/strong\u003e Collegare la schermatura di tutti i cavi dei sensori alla barra di terra del segnale dedicata sulla morsettiera. Assicurarsi che la continuità della schermatura si estenda fino alla scatola di giunzione sul campo, senza collegare a terra il filo di schermatura all'estremità del sensore sul campo, per eliminare i percorsi di corrente dei loop di massa.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCablaggio dei morsetti e distanze:\u003c\/strong\u003e Mantenere una distanza minima di 50 mm tra i cavi di alimentazione a 24 VCC\/120 VCA e le linee di segnale a bassa tensione delle termocoppie all'interno delle canaline dell'armadio. Utilizzare morsetti a pressione o cavi di sistema KS1 inseriti saldamente in posizione per prevenire la perdita di contatto dovuta alle vibrazioni elevate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquilibrio termico:\u003c\/strong\u003e Lasciare che l'armadio di controllo raggiunga condizioni ambientali operative stabili per almeno 30 minuti dopo l'accensione iniziale. In questo modo il circuito interno di compensazione del giunto di riferimento raggiunge l'equilibrio con le temperature ambientali circostanti.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":46214925680739,"sku":"AAT141-S50","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/885.jpg?v=1789865750","url":"https:\/\/www.autocontrolglobal.com\/it\/products\/aat141-s50-s2-yokogawa-centum-vp-tc-mv-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}