{"product_id":"emerson-deltav-se4302t04-do-charm-for-solenoid-control","title":"Emerson DeltaV SE4302T04 DO CHARM for Solenoid Control","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Emerson SE4302T04 is a DeltaV™ Digital Output CHARM designed for precise 24 VDC field device control.\u003cbr\u003eIt belongs to Emerson’s CHARMs Electronic Marshalling platform, enabling flexible I\/O assignment without rewiring.\u003c\/p\u003e\n\u003cp\u003eMoreover, the module simplifies project engineering by allowing late-stage signal type configuration.\u003cbr\u003eTherefore, system designers can reduce cabinet space while improving commissioning efficiency.\u003c\/p\u003e\n\u003cp\u003eThe SE4302T04 provides controlled output for solenoid coils and other binary actuators.\u003cbr\u003eIn addition, energy-limited circuitry supports safe operation in hazardous and safety-critical installations.\u003c\/p\u003e\n\u003cp\u003eHot-swap capability allows replacement without interrupting system operation.\u003cbr\u003eAs a result, maintenance teams can minimize downtime while preserving process continuity.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eProduct Type: Digital Output CHARM Module\u003cbr\u003eModel Number: SE4302T04\u003cbr\u003eManufacturer: Emerson\u003cbr\u003eSystem Platform: DeltaV™ CHARMs Electronic Marshalling\u003c\/p\u003e\n\u003cp\u003eDevice Type: 24 V DC solenoid coils\u003c\/p\u003e\n\u003cp\u003eOutput Rating (On State):\u003cbr\u003e– 100 mA continuous at 24 V DC\u003c\/p\u003e\n\u003cp\u003eOff-State Leakage Current:\u003cbr\u003e– 1 mA maximum\u003c\/p\u003e\n\u003cp\u003eLine Fault Detection Thresholds:\u003cbr\u003e– Guaranteed short circuit: less than 50 ohms load\u003cbr\u003e– Guaranteed normal status: 240 ohms to 10 kOhms load\u003cbr\u003e– Guaranteed open circuit: greater than 20 kOhms load\u003c\/p\u003e\n\u003cp\u003eConfigurable Output Behavior:\u003cbr\u003e– Momentary output\u003cbr\u003e– Continuous pulse output\u003cbr\u003e– Line fault testing\u003c\/p\u003e\n\u003cp\u003eLine Fault Test Timing:\u003cbr\u003e– 200 microseconds\u003c\/p\u003e\n\u003cp\u003eField Circuit Protection:\u003cbr\u003e– 107 mA current limiting circuit\u003cbr\u003e– Field wiring disconnect protection\u003c\/p\u003e\n\u003cp\u003eCHARM Power Requirement:\u003cbr\u003e– 116 mA maximum at 24 V DC\u003c\/p\u003e\n\u003cp\u003eCHARM Heat Dissipation:\u003cbr\u003e– 0.56 W\u003c\/p\u003e\n\u003cp\u003eIsolation:\u003cbr\u003e– Optical isolation per channel, rated up to 250 VAC\u003c\/p\u003e\n\u003cp\u003eOperating Temperature Range:\u003cbr\u003e– –40 °C to +70 °C\u003c\/p\u003e\n\u003cp\u003eRelative Humidity:\u003cbr\u003e– 5 to 95 percent, non-condensing\u003c\/p\u003e\n\u003cp\u003eAirborne Contaminants:\u003cbr\u003e– ISA-S71.04 Class G3 compliant\u003c\/p\u003e\n\u003cp\u003eShock Resistance:\u003cbr\u003e– 10 g, half-sine wave, 11 milliseconds\u003c\/p\u003e\n\u003cp\u003eVibration Resistance:\u003cbr\u003e– 1 mm peak-to-peak from 2 to 13.2 Hz\u003cbr\u003e– 0.7 g from 13.2 to 150 Hz\u003c\/p\u003e\n\u003cp\u003eProtection Rating:\u003cbr\u003e– IP20\u003c\/p\u003e\n\u003cp\u003eCertifications:\u003cbr\u003e– ATEX\u003cbr\u003e– IECEx\u003cbr\u003e– FM approvals for hazardous locations\u003c\/p\u003e\n\u003cp\u003eMounting Type:\u003cbr\u003e– DeltaV CHARM I\/O carrier\u003c\/p\u003e\n\u003cp\u003eWeight:\u003cbr\u003e– 227 g\u003c\/p\u003e\n\u003cp\u003eLifecycle Status:\u003cbr\u003e– Active product, fully supported in DeltaV systems\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of devices can the SE4302T04 control?\u003c\/strong\u003e\u003cbr\u003eIt controls 24 VDC solenoid coils, relays, and other binary actuators.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the SE4302T04 support line fault detection?\u003c\/strong\u003e\u003cbr\u003eYes, it detects open circuits, short circuits, and abnormal load resistance conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the output behavior configurable?\u003c\/strong\u003e\u003cbr\u003eYes, it supports momentary output, continuous pulse output, and line fault testing modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the SE4302T04 be replaced during operation?\u003c\/strong\u003e\u003cbr\u003eYes, the CHARM is hot-swappable without shutting down the DeltaV system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module suitable for hazardous areas?\u003c\/strong\u003e\u003cbr\u003eYes, it carries ATEX, IECEx, and FM certifications for hazardous installations.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43897985564771,"sku":"SE4302T04","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/95.1_a533a8a9-aa47-4739-b25a-1974d8528e95.jpg?v=1766108333","url":"https:\/\/www.autocontrolglobal.com\/it\/products\/emerson-deltav-se4302t04-do-charm-for-solenoid-control","provider":"AutoControl Global","version":"1.0","type":"link"}