{"product_id":"field-termination-module-usa-fs-term-0001-honeywell","title":"Modulo di Terminazione Campo USA | FS-TERM-0001 | Honeywell","description":"\u003ch3 class=\"\"\u003e\u003cstrong\u003ePanoramica del Prodotto\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eFS-TERM-0001 (Modello: FS-TERM-0001)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eè un modulo di terminazione sul campo e terminatore bus ad alta precisione specificamente progettato per i sistemi Honeywell Safety Manager e Fail Safe Control (FSC).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eQuesto modulo ha una doppia funzione:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eche funge da interfaccia fisica per il cablaggio sul campo e fornisce l'adattamento di impedenza essenziale (terminazione del bus) per le reti di comunicazione I\/O ridondanti.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eUtilizzando il\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eFS-TERM-0001 (Numero di parte: FS-TERM-0001)\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003el'integrità del sistema è mantenuta attraverso l'eliminazione delle riflessioni del segnale sul backplane di sicurezza o sul bus di comunicazione.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eQuesto è fondamentale nei Sistemi Strumentati di Sicurezza (SIS) ad alta disponibilità utilizzati nelle raffinerie di petrolio e gas,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eimpianti petrolchimici,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ee impianti di generazione di energia.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eFS-TERM-0001 (Numero d'ordine: FS-TERM-0001)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eassicura che i segnali digitali e analogici dai sensori sul campo raggiungano il processore di sicurezza senza distorsioni,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emantenendo l'Expertise e l'Affidabilità (E-E-A-T) richieste per i loop di sicurezza con classificazione SIL.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003e\u003cstrong\u003eSpecifiche Tecniche Dettagliate\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eFS-TERM-0001\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eè progettato per mantenere la chiarezza del segnale nelle architetture hardware mission-critical.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProduttore\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNumero Modello\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eFS-TERM-0001\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTipo di Prodotto\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTerminatore bus \/ Modulo di terminazione sul campo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSistemi compatibili\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell Safety Manager,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSistemi I\/O ridondanti FSC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFunzione\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAdattamento dell'impedenza del bus di comunicazione e interfaccia di cablaggio sul campo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTipo di terminazione\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMorsetti a vite di qualità industriale per connettività sicura\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCompatibilità del segnale\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupporto multicanale per segnali digitali e analogici\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTensione di esercizio\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDeterminato dal modulo I\/O associato (terminazione passiva)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIsolamento\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIsolamento ad alta dielettricità per proteggere la logica di sistema da sovratensioni sul campo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMontaggio\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ePannello cabinet o montaggio su chassis (rack Safety Manager standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensioni\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5.\u003c\/span\u003e\u003cspan class=\"\"\u003e1 cm x 25.\u003c\/span\u003e\u003cspan class=\"\"\u003e4 cm x 11.\u003c\/span\u003e\u003cspan class=\"\"\u003e4 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePeso netto\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e63 kg (1.\u003c\/span\u003e\u003cspan class=\"\"\u003e39 lbs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePeso di spedizione\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 kg\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"\"\u003e con imballaggio protettivo)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePaese di origine\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44029188866147,"sku":"FS-PDC-IOS05","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/124.1_31801112-2594-40b7-96c9-4b9b68da68c4.jpg?v=1772261377","url":"https:\/\/www.autocontrolglobal.com\/it\/products\/field-termination-module-usa-fs-term-0001-honeywell","provider":"AutoControl Global","version":"1.0","type":"link"}