{"product_id":"ge-sr489-p5-hi-a20-e-management-relay-enhanced-display","title":"369-HI-R-M-F-P1-0-E | Sistema di Gestione Motore GE 369（副本）","description":"\u003ch3\u003e\u003cstrong\u003ePanoramica del Prodotto\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e369-HI-R-M-F-P1-0-E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(codice d’ordine\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e369HIRMFP10E\u003c\/strong\u003e) è un autorevole Relè di Protezione Motore della serie GE Multilin 369. Questo modulo è una necessità meccanica per il monitoraggio e la protezione di motori da media a grande potenza contro stress elettrici e meccanici. Integrando un sofisticato modello termico, il rilevamento della corrente e la logica di comunicazione in un telaio robusto, il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e369-HI-R-M-F-P1-0-E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eassicura un funzionamento deterministico del motore. Serve come barriera protettiva primaria, prevenendo il danneggiamento dell’isolamento e danni meccanici dovuti a sovraccarichi, guasti a terra o squilibri di fase in settori industriali critici come miniere, petrolio e gas e trattamento delle acque.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifiche Tecniche Dettagliate\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttributo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDettagli\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduttore\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Multilin \/ General Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumero Modello\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e369-HI-R-M-F-P1-0-E\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumero Parte\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e369HIRMFP10E\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSerie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSistema di Gestione Motori 369\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlimentazione (HI)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e88–300 VDC \/ 70–265 VAC (Gamma Alta)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eComunicazione (R)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDoppie porte RS485 con supporto Modbus RTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMisurazione (M)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMisurazione Avanzata (Corrente, Tensione, Potenza, Frequenza)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFibra Ottica (F)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePorta in fibra ottica per comunicazione senza interferenze\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIngressi di Fase (P1)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSecondari CT da 1 A per monitoraggio di fase ad alta precisione\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAmbientale (E)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRivestimento conformale per ambienti gravosi\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunzione Primaria\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModellazione Termica Avanzata e Protezione\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura di Funzionamento\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C a +70 °C (-40 °F a 158 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,0–2,0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eLinee Guida Ingegneristiche e Operative\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompetenza nella Gestione Termica\u003c\/strong\u003e: Il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e369-HI-R-M-F-P1-0-E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizza un algoritmo termico proprietario che considera il feedback RTD e le statistiche di corrente. Questa competenza consente la massima utilizzazione del motore calcolando la reale capacità termica utilizzata, essenziale per proteggere contro avvii a caldo ripetuti.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLogica di Comunicazione Ridondante\u003c\/strong\u003e: Dotato dell’opzione \"R\", questo relè offre doppie porte RS485. Questo design affidabile garantisce che, in caso di guasto di un canale di comunicazione, il sistema SCADA mantenga la visibilità in tempo reale dello stato del motore, evitando operazioni non monitorate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuite di Protezione Autorevole\u003c\/strong\u003e: L’unità include protezioni integrate per rotore bloccato, inversione di fase e guasti a terra. Il gruppo di ingressi \"P1\" da 1A è ottimizzato per rilevamenti ad alta sensibilità, permettendo un rapido isolamento dei guasti prima che il calore localizzato causi danni permanenti allo statore.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResistenza ad Ambienti Gravosi\u003c\/strong\u003e: La designazione \"E\" conferma che le schede interne sono rivestite conformalmente. Questo è un requisito ingegneristico per installazioni in ambienti corrosivi, come impianti chimici o di trattamento acque reflue, dove contaminanti aerodispersi potrebbero degradare le schede logiche.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ Tecniche\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eD: Quali sono le principali differenze tra la serie 369 e la serie 750?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eR: Il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e369-HI-R-M-F-P1-0-E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè specificamente un sistema di \"Gestione Motori\" progettato per integrazione compatta nei centri di controllo motori (MCC). La serie 750 è un sistema più completo di \"Protezione Motori\" tipicamente usato per motori di utilità più grandi e complessi che richiedono un numero maggiore di ingressi\/uscite.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eD: Questo relè può essere usato con secondari CT da 5A?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eR: Questa configurazione specifica (\u003cstrong\u003eP1\u003c\/strong\u003e) è progettata per secondari CT di fase da 1A. Usarlo con CT da 5A comporterà misurazioni errate e interventi di protezione non corretti. La migliore pratica professionale prevede di abbinare l’hardware del relè al rapporto CT presente in loco.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eD: In che modo la porta in fibra ottica (F) migliora l’affidabilità del sistema?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eR: La porta in fibra ottica fornisce un’isolamento elettrico totale per i segnali di comunicazione. In ambienti con elevata interferenza elettromagnetica (EMI), come vicino a grandi azionamenti a frequenza variabile (VFD), questa porta garantisce che i pacchetti dati non vengano corrotti.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44071757545571,"sku":"SR489-P5-HI-A20","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/365._888a63c7-3bec-4a00-b61a-8702a76a7e80.jpg?v=1773999374","url":"https:\/\/www.autocontrolglobal.com\/it\/products\/ge-sr489-p5-hi-a20-e-management-relay-enhanced-display","provider":"AutoControl Global","version":"1.0","type":"link"}