{"product_id":"honeywell-8c-taid61-series-8-analog-input-module","title":"Honeywell Serie 8C-TAID61 | Modulo di ingresso analogico","description":"\u003ch2\u003eModulo di Ingresso Analogico Honeywell 8C-TAID61\u003c\/h2\u003e\n\u003cp\u003eConfigurato per l'acquisizione di segnali ad alta precisione nelle reti di controllo Serie 8, il \u003cstrong\u003eHoneywell 8C-TAID61\u003c\/strong\u003e (Modulo di Ingresso Analogico \u003cstrong\u003e8C-TAID61\u003c\/strong\u003e) fornisce l'esecuzione fisica\/elettrica diretta del monitoraggio a 16 canali del loop 4-20 mA.\u003c\/p\u003e\n\u003ch3\u003eSpecifiche Hardware\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecifiche\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModello\u003c\/td\u003e\n\u003ctd\u003e8C-TAID61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarca\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigine\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003ctd\u003e0,8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensioni\u003c\/td\u003e\n\u003ctd\u003e130 mm x 25 mm x 250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura di esercizio\u003c\/td\u003e\n\u003ctd\u003e-20 °C a +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumo energetico\u003c\/td\u003e\n\u003ctd\u003e6 W a 8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanali di ingresso\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRisoluzione\u003c\/td\u003e\n\u003ctd\u003e16 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecisione\u003c\/td\u003e\n\u003ctd\u003e+\/- 0,1% del campo di misura\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCaratteristiche di Controllo di Processo DCS e Isolamento\u003c\/h3\u003e\n\u003cp\u003eIl \u003cstrong\u003e8C-TAID61\u003c\/strong\u003e utilizza un'architettura di isolamento canale-canale per minimizzare le interferenze da loop di massa nell'ambiente Honeywell Experion PKS. Supporta l'integrazione del protocollo loop 4-20 mA HART, permettendo al DCS di estrarre variabili diagnostiche secondarie dai trasmettitori di campo. Inoltre, il modulo implementa l'isolamento galvanico canale-backplane per sopprimere la propagazione del rumore in modalità comune. I circuiti di monitoraggio attivo dei guasti rilevano continuamente condizioni di circuito aperto, fornendo un feedback diagnostico immediato al controller C300 tramite il bus backplane. L'integrazione di convertitori analogico-digitale a 16 bit garantisce una precisa linearizzazione del segnale per loop di processo critici.\u003c\/p\u003e\n\u003ch3\u003eDomande Frequenti\u003c\/h3\u003e\n\u003cp\u003eD: Il modulo supporta la sostituzione a caldo mentre il rack I\/O è alimentato?\u003c\/p\u003e\n\u003cp\u003eR: Sì, l'architettura Serie 8 consente l'estrazione e l'inserimento del modulo senza richiedere lo spegnimento completo del sistema, a condizione che l'IOTA rimanga inserito.\u003c\/p\u003e\n\u003cp\u003eD: Come indica il modulo una condizione di circuito aperto su un canale specifico?\u003c\/p\u003e\n\u003cp\u003eR: Il modulo esegue un polling diagnostico continuo; se la corrente del loop scende sotto la soglia configurata, la logica interna di guasto attiva un flag di stato all'interno del controller Experion PKS.\u003c\/p\u003e\n\u003ch3\u003eLinee Guida per l'Installazione in Campo\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInserire saldamente il modulo nel telaio I\/O Serie 8, assicurandosi che il meccanismo di bloccaggio meccanico si innesti per stabilire una connessione affidabile con il backplane.\u003c\/li\u003e\n\u003cli\u003eInstradare il cablaggio di campo attraverso canaline dedicate per evitare accoppiamenti induttivi da linee di alimentazione ad alta tensione adiacenti.\u003c\/li\u003e\n\u003cli\u003eVerificare che l'alimentazione del loop a 24 VDC sia correttamente cablata ai terminali IOTA prima di finalizzare la connessione ai trasmettitori di campo.\u003c\/li\u003e\n\u003cli\u003eIspezionare l'integrità del rivestimento conformale prima dell'installazione in ambienti con contaminanti atmosferici corrosivi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eModulo di Ingresso Analogico Honeywell 8C-TAID61\u003c\/h4\u003e\n\u003cp\u003eConfigurato per l'acquisizione di segnali ad alta precisione nelle reti Honeywell Experion PKS e Serie 8 C300, il \u003cstrong\u003eHoneywell 8C-TAID61\u003c\/strong\u003e (Modulo di Ingresso Analogico \u003cstrong\u003e8C-TAID61\u003c\/strong\u003e) fornisce l'esecuzione elettrica diretta delle misurazioni analogiche 4-20 mA.\u003c\/p\u003e\n\u003ch3\u003eSpecifiche Hardware\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecifiche\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModello\u003c\/td\u003e\n\u003ctd\u003e8C-TAID61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarca\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigine\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003ctd\u003e0,8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensioni\u003c\/td\u003e\n\u003ctd\u003e130 mm x 25 mm x 250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura di esercizio\u003c\/td\u003e\n\u003ctd\u003e-20 °C a +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumo energetico\u003c\/td\u003e\n\u003ctd\u003e6 W a 8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanali di ingresso\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRisoluzione\u003c\/td\u003e\n\u003ctd\u003e16 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecisione\u003c\/td\u003e\n\u003ctd\u003e+\/- 0,1% del campo di misura\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCaratteristiche di Controllo di Processo DCS e Comunicazione\u003c\/h3\u003e\n\u003cp\u003eIl \u003cstrong\u003e8C-TAID61\u003c\/strong\u003e impiega isolamento canale-canale per mitigare il rumore in modalità comune e prevenire loop di massa all'interno di loop di processo complessi. Integra il supporto al protocollo loop 4-20 mA HART, consentendo la comunicazione bidirezionale tra trasmettitori di campo e controller DCS. Ogni canale utilizza una conversione A\/D ad alta velocità per garantire aggiornamenti deterministici dei dati attraverso il bus backplane. Inoltre, il modulo incorpora il rilevamento attivo di circuito aperto e il monitoraggio diagnostico interno per segnalare immediatamente i guasti lato campo all'ambiente Experion PKS. Queste caratteristiche mantengono un'integrità del segnale rigorosa durante sequenze di controllo critiche.\u003c\/p\u003e\n\u003ch3\u003eDomande Frequenti\u003c\/h3\u003e\n\u003cp\u003eD: Il 8C-TAID61 supporta l'alimentazione del loop lato campo tramite il modulo?\u003c\/p\u003e\n\u003cp\u003eR: L'architettura del modulo richiede alimentazione esterna del loop per i trasmettitori; tuttavia, fornisce il condizionamento del segnale e l'isolamento galvanico necessari per interfacciarsi con strumenti a 2 e 4 fili.\u003c\/p\u003e\n\u003cp\u003eD: Questo modulo è compatibile con configurazioni I\/O ridondanti?\u003c\/p\u003e\n\u003cp\u003eR: Sì, il modulo supporta operazioni I\/O ridondanti se abbinato a telai I\/O Serie 8 e configurazioni di processore I\/O compatibili per garantire percorsi di segnale ad alta disponibilità.\u003c\/p\u003e\n\u003ch3\u003eLinee Guida per l'Installazione in Campo\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAssicurarsi che il backplane del telaio I\/O fornisca un riferimento di massa pulito per massimizzare l'efficacia delle barriere di isolamento galvanico.\u003c\/li\u003e\n\u003cli\u003eInstradare i cavi del segnale analogico attraverso condotti metallici dedicati, separati dalle linee di alimentazione AC ad alta tensione per minimizzare le interferenze elettromagnetiche indotte.\u003c\/li\u003e\n\u003cli\u003eVerificare che il cablaggio dei trasmettitori di campo mantenga la polarità corretta ai terminali IOTA per evitare errori di rilevamento circuito aperto.\u003c\/li\u003e\n\u003cli\u003eApplicare la coppia di serraggio appropriata alle viti del blocco terminale per fissare le connessioni del loop 4-20 mA e prevenire deriva del segnale dovuta a resistenza di contatto.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43853959954531,"sku":"8C-TAID61","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/212_03c4f0ff-3ca9-493b-91cf-b7c9248a78cc.jpg?v=1764062059","url":"https:\/\/www.autocontrolglobal.com\/it\/products\/honeywell-8c-taid61-series-8-analog-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}