{"product_id":"mvi69e-mbtcp-prosoft-enhanced-modbus-tcp-communication","title":"MVI69E-MBTCP | ProSoft | Comunicazione Modbus TCP migliorata","description":"\u003ch3\u003e\u003cstrong\u003eModulo di Comunicazione Avanzato ProSoft MVI69E-MBTCP Modbus TCP\/IP per CompactLogix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003ePanoramica del Prodotto\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIl ProSoft\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI69E-MBTCP (MV169E-MBTCP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè un modulo di comunicazione Modbus TCP\/IP avanzato progettato per la piattaforma Allen-Bradley CompactLogix™ (1769 I\/O). In quanto versione \"Avanzata\", offre una maggiore velocità di trasmissione dati e un'integrazione semplificata rispetto ai moduli tradizionali. Permette ai controllori CompactLogix di interfacciarsi senza soluzione di continuità con fino a 30 dispositivi Modbus TCP\/IP, operando contemporaneamente sia come Cliente (Master) sia come Server (Slave). Per facilitare le attività di progettazione, ProSoft fornisce un Profilo Aggiuntivo (AOP) e un'Istruzione Aggiuntiva (AOI) dedicati per l'ambiente Studio 5000 Logix Designer, consentendo una messa in servizio rapida e un'integrazione dei tag simile a quella nativa.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eScenari di Applicazione Industriale\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAutomazione di Sottostazioni\u003c\/strong\u003e: Monitoraggio e controllo di contatori di energia, relè di protezione e dispositivi elettronici intelligenti (IED) tramite Ethernet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAcqua e Trattamento delle Acque Reflue\u003c\/strong\u003e: Integrazione di unità di telemetria remota (RTU) e misuratori di portata in un sistema centralizzato CompactLogix.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGestione degli Edifici (BMS)\u003c\/strong\u003e: Interfacciamento con refrigeratori, caldaie e regolatori di illuminazione che utilizzano il protocollo Modbus TCP.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalisi della Produzione\u003c\/strong\u003e: Raccolta in tempo reale dei dati di consumo energetico da inverter di frequenza (VFD) e avviatori motore specializzati.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifiche Tecniche\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eLe seguenti caratteristiche tecniche definiscono l'hardware e le capacità di comunicazione del\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI69E-MBTCP (MV169E-MBTCP)\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParametro\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDettagli della Specifica\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumero di Modello\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMVI69E-MBTCP \/ MV169E-MBTCP\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinea di Prodotto\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModuli di Comunicazione Avanzati inRAx\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibilità Piattaforma\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControllori CompactLogix L3x, L2x e L1x con bus 1769\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupporto Protocollo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus TCP\/IP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModalità di Funzionamento\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCliente e Server simultanei\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePorta Ethernet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 × 10\/100 Mbps RJ45 (Schermata)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacità di Connessione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFino a 30 Client e 20 Server\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCorrente sul Backplane\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e800 mA a 5 VCC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDatabase Interno Dati\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.000 registri\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupporto Software\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProfilo Aggiuntivo (AOP) e Istruzione Aggiuntiva (AOI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eServer Web\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrato per diagnostica e stato del modulo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura di Funzionamento\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C a 60 °C (32 °F a 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIndicatori LED\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOK, Link\/Attività, Stato Modbus, Attività Backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43991919820899,"sku":"MV169E-MBTCP","price":260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/60._8aca9968-ad1c-4a84-bb74-18f8ef1d91f4.jpg?v=1770606532","url":"https:\/\/www.autocontrolglobal.com\/it\/products\/mvi69e-mbtcp-prosoft-enhanced-modbus-tcp-communication","provider":"AutoControl Global","version":"1.0","type":"link"}