{"product_id":"kl3032x1-ba1-analog-input-charm-emerson-deltav-charms","title":"KL3032X1-BA1 Analog Input CHARM | Emerson DeltaV CHARMs","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson DeltaV KL3032X1-BA1\u003c\/strong\u003e, also referenced as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSE4303T02\u003c\/strong\u003e, is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 VDC powered Analog Input CHARM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for flexible current signal measurement in DeltaV CHARMs I\/O systems.\u003cbr\u003eThis CHARM supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA and 0–20 mA signals\u003c\/strong\u003e, enabling direct connection of modern field transmitters without additional interface modules.\u003c\/p\u003e\n\u003cp\u003eMoreover, the module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2-wire, 3-wire, and 4-wire devices\u003c\/strong\u003e, simplifying field wiring while reducing engineering complexity.\u003cbr\u003eTherefore, it plays a critical role in electronic marshalling strategies where late-stage I\/O changes are expected.\u003c\/p\u003e\n\u003cp\u003eAs part of Emerson’s CHARMs architecture, the KL3032X1-BA1 delivers hot-swappable installation, automatic configuration, and consistent performance across wide environmental conditions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eProduct Type: Analog Input CHARM\u003cbr\u003eModel \/ Order Code: KL3032X1-BA1\u003cbr\u003eCHARM Identifier: SE4303T02\u003cbr\u003eManufacturer: Emerson\u003cbr\u003eSystem Compatibility: DeltaV™ CHARMs Electronic Marshalling\u003c\/p\u003e\n\u003cp\u003eSupported Signal Types:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e4–20 mA with or without HART\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0–20 mA optional\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNominal Signal Range: 4–20 mA\u003cbr\u003eFull Signal Range: 0 to 24 mA\u003c\/p\u003e\n\u003cp\u003eSupported Field Devices:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2-wire loop-powered transmitters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e3-wire devices powered through CHARM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e4-wire externally powered devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eField Power (2-wire): 15.0 V at 20 mA with 24 V DC input\u003cbr\u003eInput Impedance: 250 Ω ±1%\u003c\/p\u003e\n\u003cp\u003eAccuracy:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e±0.1% of span from 0 to 60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e±0.25% of span from –40 to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRepeatability: 0.05% of span\u003cbr\u003eResolution: 16-bit A\/D converter\u003c\/p\u003e\n\u003cp\u003eCalibration: None required\u003cbr\u003eField Circuit Protection: 30 mA current limiting and wiring disconnect\u003c\/p\u003e\n\u003cp\u003eCHARM Power Requirement:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e36 mA max at 24 V DC for 2-wire devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e12 mA max at 24 V DC for 3-wire and 4-wire devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHeat Dissipation: 0.33 W\u003c\/p\u003e\n\u003cp\u003eHART Support:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHART v7 pass-through for AMS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHART variables and device status available for control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHART Update Rate: Faster than one second, depending on device and network loading\u003c\/p\u003e\n\u003cp\u003eOperating Temperature: –40 °C to +70 °C\u003cbr\u003eMounting Method: DeltaV CHARM I\/O Carrier\u003cbr\u003eInstallation: Hot-swappable during system operation\u003cbr\u003eLifecycle Status: Active and fully supported by Emerson\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What signal types does KL3032X1-BA1 support?\u003c\/strong\u003e\u003cbr\u003eA1: It supports 4–20 mA and optional 0–20 mA current signals, with or without HART.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can this CHARM power field transmitters directly?\u003c\/strong\u003e\u003cbr\u003eA2: Yes, it provides loop power for 2-wire devices and supports 3-wire and 4-wire configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is HART communication supported?\u003c\/strong\u003e\u003cbr\u003eA3: Yes, HART v7 pass-through is supported for AMS diagnostics and control variables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Does the module require calibration?\u003c\/strong\u003e\u003cbr\u003eA4: No, the KL3032X1-BA1 is factory calibrated and requires no user calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Can the CHARM be replaced while the system is running?\u003c\/strong\u003e\u003cbr\u003eA5: Yes, it supports hot-swap installation in DeltaV CHARMs I\/O carriers.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43898004144227,"sku":"SE4303T02 KL3032X1-BA1","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/80._ffced357-7a86-4349-942b-99e1020f2d58.jpg?v=1766109497","url":"https:\/\/www.autocontrolglobal.com\/kk\/products\/kl3032x1-ba1-analog-input-charm-emerson-deltav-charms","provider":"AutoControl Global","version":"1.0","type":"link"}