Product Description
The Emerson KL4501X1-BF1 is a precision CHARM address plug designed for seamless integration with DeltaV Electronic Marshalling systems. It assigns a unique address to each CHARM I/O module, ensuring proper communication and control within distributed control systems. The module is ideal for industrial automation environments, including hazardous locations, due to its rugged construction and certified compliance with ATEX, IECEx, FM, and UKEX standards.
The KL4501X1-BF1 features snap-in installation on CHARM baseplates and supports Address Plug #6 (Position 3E). Moreover, it operates reliably under a wide ambient temperature range from -40°C to +70°C, and its compact dimensions allow efficient system assembly in tight enclosures. This plug provides low-power operation at +6.3 VDC with minimal current draw, making it suitable for energy-efficient control systems.
Technical Specifications
| Attribute | Specification |
|---|---|
| Model | KL4501X1-BF1 |
| Type | CHARM Address Plug |
| System Compatibility | DeltaV Electronic Marshalling |
| Function | Assigns unique address to CHARM I/O modules |
| Address Position | Plug #6 (Position 3E) |
| Mounting | Snap-in on CHARM baseplates |
| Power Rating | +6.3 VDC at 2 mA |
| Ambient Temperature | -40°C to +70°C |
| Shock Resistance | 10g, half-sine wave for 11 ms |
| Vibration Resistance | 1 mm peak-to-peak (2–13.2 Hz); 0.7g (13.2–150 Hz) |
| Humidity | 5%–95%, non-condensing |
| Airborne Contaminants | ISA-S71.04–1985 Class G3 |
| Hazardous Area Ratings | II 3G Ex ec IIC Gc / Class I Div 2 Groups A–D |
| Certifications | ATEX, IECEx, FM, UKEX |
| Dimensions | 107 × 41 × 105 mm |
| Weight | 0.04 kg |
| Country of Origin | USA |
FAQ
Q1: What is the purpose of the KL4501X1-BF1 address plug?
A1: It assigns a unique address to each CHARM I/O module in a DeltaV system.
Q2: Which address position does this plug support?
A2: This unit is designed for Address Plug #6, Position 3E.
Q3: Can it operate in hazardous environments?
A3: Yes, it is certified for ATEX, IECEx, FM, and UKEX hazardous area use.
Q4: What is the power requirement for this plug?
A4: It operates at +6.3 VDC with a current of 2 mA on the CHARM bus.
Q5: How is the plug installed?