  • Manufacturer: Triconex

  • Part Number: RO-3451

  • Condition:New with Original Package

  • Product Type: Relay Output Module for Emergency Shutdown Systems

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

TRICONEX RO‑3451 Relay Output Safety Module

Product Overview

The RO‑3451 Relay Output Safety Module delivers reliable ON/OFF control for field actuators and devices in safety-critical industrial environments. Moreover, it ensures precise signaling for emergency shutdown (ESD), fire & gas detection, and process safety systems. Its SIL3 certification and hot-swappable design make it ideal for mission-critical applications requiring uninterrupted operation.

Technical Specifications

Parameter Specification
Model Number RO‑3451
Product Type Relay Output Safety Module
System Triconex TMR Safety System
Output Channels 8 isolated relay output channels
Relay Contact Type Form C (SPDT – Single Pole Double Throw)
Contact Ratings 5 A @ 250 VAC, 2 A @ 30 VDC
Isolation Voltage 4000 V RMS channel-to-coil
Operational Life 100,000 mechanical cycles
Response Time ≤10 ms (coil activation)
Relay Type Solid-state relay (depending on version)
Operating Voltage 24 VDC
Output Current Capacity Up to 10 A per relay (depending on configuration)
Operating Temperature –40 °C to +85 °C
Storage Temperature –40 °C to +85 °C
Dimensions 4.3 × 18.8 × 21.7 cm
Weight 1.36 kg
Certifications IEC 61508 SIL3
Mounting Triconex chassis compatible, hot-swappable

FAQ

Q: How many output channels does the RO‑3451 provide?
A: The module provides 8 isolated relay output channels for flexible field control.

Q: What type of relay contacts are used?
A: It uses Form C (SPDT – Single Pole Double Throw) relay contacts for versatile switching.

Q: What is the maximum voltage and current rating per relay?
A: Contact ratings are 5 A @ 250 VAC and 2 A @ 30 VDC, with output current up to 10 A depending on configuration.

Q: Is the module suitable for SIL3 applications?
A: Yes, the RO‑3451 is certified to SIL3 safety integrity standards.

Q: Can it operate in extreme temperatures?
A: Yes, it operates reliably between –40 °C and +85 °C, suitable for harsh industrial environments.