{"product_id":"1c31113g05-emerson-core-function-keyword-new-original-stock","title":"1C31113G05 Emerson Core Function Keyword | New \u0026 Original Stock","description":"\u003ch1\u003eEmerson 1C31113G05 Ovation Series Analog Input Modules\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson 1C31113G05\u003c\/strong\u003e serves as the primary \u003cstrong\u003e1C31113G05\u003c\/strong\u003e Analog Input Module utilized to execute raw sensor signal conditioning across Ovation Distributed Control System platforms. The hardware processes incoming continuous loop currents spanning a 0-20 mA calibration threshold, converting physical transmitter variables into digitized datasets for controller execution. Internal instrumentation arrays stabilize fluctuating field data loops directly at the hardware register interface, transmitting filtered process coordinates across the local backplane bus without degrading execution scan cycles.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e1C31113G05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eOvation (by Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e3.0 kg shipping mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eStandard Ovation chassis-slot form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e24 VDC nominal supply input tracking constraints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eInput Channel Scope\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eMultiple independent analog sensing lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eLoop Signal Range\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e0-20 mA current loop input configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eCircuit Isolation\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eChannel-to-channel and channel-to-system physical isolation barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eExecution Latency\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e\u0026lt; 5 ms response time window\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eStorage Temp\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eHumidity Capacity\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e5-95% non-condensing relative humidity index\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003eMechanical Shock\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e10 g (11 ms half-sine) physical wave limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003eVibration Tolerance\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e0.7 g absolute acceleration from 13.2 to 150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003eChassis Protection\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003eIP20 ingress rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003eFrame Mounting\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003eRack-mounted installation inside designated Ovation I\/O chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe physical layout of the 1C31113G05 features individual channel-to-channel isolation barriers designed to block unpredictable common-mode electrical potentials across extended plant wiring nets. By decoupling each current return path, the hardware prevents local field wiring shorts from altering adjacent tracking lines. This electrical architecture maintains signal stability, allowing secondary digital variables associated with the 4-20 mA HART loop protocol to pass over the analog current baseline into system memory registers without inductive distortion, facilitating concurrent device diagnostics and remote calibration sequences while holding control loop integrity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What hot-swap parameters govern the physical removal of the 1C31113G05 module during active controller execution?\u003c\/p\u003e\n\u003cp\u003eA: The module configuration allows physical extraction and insertion while the Ovation backplane bus remains energized. Pulling the active module instantly interrupts all incoming 0-20 mA loop current tracks, causing the host controller to flag an open-circuit I\/O status error without introducing operational fault states onto adjacent rack components.\u003c\/p\u003e\n\u003cp\u003eQ: How does the internal diagnostic system indicate a transmitter loop wiring break or field sensor power loss?\u003c\/p\u003e\n\u003cp\u003eA: The card contains continuous loop monitoring circuits that track minimum baseline input levels. When an external wire fracture occurs or a transmitter de-energizes, dropping the signal current below the calibrated low-scale threshold, the module flags a local channel open circuit error and routes a diagnostic fault bit to the main system control log.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 1C31113G05 handle non-isolated 4-wire powered transmitters without external grounding modifications?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Because the module incorporates individual channel-to-channel isolation, it can accommodate mixed combinations of 2-wire loops and externally powered 4-wire transmitters on the same rack assembly without creating parasitic ground loops that corrupt analog conversion accuracy.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment Lock:\u003c\/strong\u003e Position the module frame inside the guide rails of the Ovation I\/O rack. Slide the assembly inward until the structural retention latch engages the backplane connector pins to ensure continuous low-impedance contact performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Ground Separation:\u003c\/strong\u003e Terminate all instrumentation cable shield braids at the designated master earth ground bus bar inside the local marshalling cabinet. Keep the outer shield layer completely isolated at the field junction box to avert parasitic loop current generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Track Routing:\u003c\/strong\u003e Place all 0-20 mA analog input wiring inside separate, grounded steel conduits. Maintain physical distance between these measurement tracks and high-voltage AC motor lines or variable frequency drive (VFD) paths to block external electromagnetic noise injection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFitting Engagement Limits:\u003c\/strong\u003e Verify exactly 5 full threads of NPT engagement at all conduit interface connections on field junction boxes to preserve the environmental seal against moisture entry and ambient atmospheric contaminants.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Ovation","offers":[{"title":"Default Title","offer_id":44215897555043,"sku":"1C31113G05","price":228.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/263._a272fb56-9432-4298-9d20-907049769bad.jpg?v=1779783456","url":"https:\/\/www.autocontrolglobal.com\/lt\/products\/1c31113g05-emerson-core-function-keyword-new-original-stock","provider":"AutoControl Global","version":"1.0","type":"link"}