{"product_id":"7sj5311-4ea02-1aa0-ff-siprotec-7sj531-feeder-protection-relay","title":"7SJ5311-4EA02-1AA0\/FF SIPROTEC 7SJ531 Feeder Protection Relay","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 7SJ5311-4EA02-1AA0\/FF operates as a sophisticated numerical protection relay within the SIPROTEC 7SJ531 series. It provides primary protection for radial or looped feeders and motor assets in medium and high-voltage industrial power distribution networks. This multi-functional unit executes complex protection algorithms to detect overcurrent, earth faults, and frequency deviations within milliseconds, isolating faults to prevent extensive equipment damage. We supply this unit as 100% brand new, original factory-sealed equipment.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSiemens\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7SJ5311-4EA02-1AA0\/FF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIPROTEC 7SJ531\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOvercurrent, Earth Fault, Voltage, Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 Current Transformer (CT), 3 Voltage Transformer (VT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital I\/O\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11 Binary Inputs, 5 Alarm Relays, 4 Command Relays\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 61850, IEC 870-5-103, PROFIBUS, RS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration Software\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIGSI 4 \/ DIGSI 5 Compatible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Graphic Display for Local HMI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAuxiliary Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWide-range DC Options (24V to 250V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e144 × 144 × 115 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–25°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Monitoring and Metering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 7SJ5311-4EA02-1AA0\/FF eliminates the need for separate metering hardware by providing high-accuracy measurement of current, voltage, power, and frequency. It tracks both active and reactive energy, supplying critical data for load management and energy audits directly to the SCADA system via IEC 61850.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Fault Diagnostics and Event Logging\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis relay captures sequence-of-events and fault records with high time-stamping precision. Engineers utilize DIGSI software to download these records, enabling rapid root-cause analysis after a trip. This functionality reduces industrial downtime by distinguishing between transient surges and permanent hardware faults.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModular Safety and Flexibility\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe modular hardware design allows for seamless integration into diverse panel configurations. With 11 binary inputs and 9 total relay outputs, the 7SJ5311-4EA02-1AA0\/FF manages complex interlocking logic and signaling without requiring additional PLC hardware. The wide-range auxiliary voltage support simplifies spare parts inventory, as one unit covers multiple DC voltage standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Environmental Resilience\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSiemens engineered the 7SJ5311-4EA02-1AA0\/FF for the harsh conditions of industrial substations. It maintains reliable logic execution in temperatures ranging from –25°C to +60°C. The IP20-rated housing protects internal numerical circuitry from atmospheric contaminants, while the panel-mounted design secures the device against high-vibration environments.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this relay support the IEC 61850 communication standard?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 7SJ5311-4EA02-1AA0\/FF supports IEC 61850, allowing for seamless integration into modern digital substations and vendor-neutral SCADA environments. It also supports legacy protocols like IEC 870-5-103 for existing installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I configure the protection curves locally?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe relay features a built-in graphic display and navigation keys for local HMI access. While DIGSI software provides the most efficient configuration experience, authorized personnel can adjust parameters and view measured values directly at the device faceplate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of having 5 CT and 3 VT inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe high density of analog inputs allows the relay to perform sensitive directional earth-fault detection and voltage-dependent protection functions. This configuration ensures the relay accurately calculates power values and monitors synchronization conditions across the circuit breaker.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43770004045923,"sku":"7SJ5311-4EA02-1AA0\/FF","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/19_7d8c76b3-3a90-49fb-b2dd-48792c15aa79.jpg?v=1776150484","url":"https:\/\/www.autocontrolglobal.com\/lv\/products\/7sj5311-4ea02-1aa0-ff-siprotec-7sj531-feeder-protection-relay","provider":"AutoControl Global","version":"1.0","type":"link"}