{"product_id":"dio216-4-bachmann-m1-automation-system-datasheet-technical-manual","title":"DIO216\/4 Bachmann M1 Automation System Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eBachmann DIO216\/4 Digital I\/O Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for Specific Technical Task in System\/Network Name, the \u003cstrong\u003eBachmann DIO216\/4\u003c\/strong\u003e (\u003cstrong\u003eDIO216\/4\u003c\/strong\u003e Digital Input\/Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDIO216\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 mm x 25 mm x 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 digital inputs, 4 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e24 VDC (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e2-3 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e24 VDC (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-system up to 1500 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Latency\u003c\/td\u003e\n\u003ctd\u003eInputs: \u0026lt; 5 ms, Outputs: \u0026lt; 2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe DIO216\/4 module utilizes the native backplane bus communication velocity link of the Bachmann M1 architecture to execute deterministic cyclic logic synchronization. This configuration balances high-density scaling with strict time parameters, routing 16 input processing states and 4 independent output execution commands through a unified driver stack. Integrated channel status LEDs communicate with the main processing matrix via onboard system firmware flash compatibility layers. Galvanic isolation circuits up to 1500 V RMS isolate the logical backplane execution from external electrical transients across the physical field wiring terminals, eliminating the risk of data corruption or parity failure during simultaneous high-frequency switching operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Are there operational restrictions regarding the hot-swap capabilities of the DIO216\/4 module?\u003c\/p\u003e\n\u003cp\u003eA: Live mechanical extraction and insertion are supported within the M1 rack profile without shutting down the system backplane power supply. However, field terminal connections must be isolated prior to hot-swapping to avoid transient electrical arcing across the module contacts.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle backplane current constraints when driving all 4 output channels at maximum capacity?\u003c\/p\u003e\n\u003cp\u003eA: The 4 W rated internal power consumption covers the digital logic circuit requirements drawn from the system bus. The 0.5 A per-channel load for the 4 digital outputs must be sourced from an external, isolated 24 VDC field power supply to prevent thermal overload on the internal backplane traces.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting Profiles:\u003c\/strong\u003e Secure the housing to standard symmetric steel DIN rail sub-assemblies inside a dust-free industrial cabinet. Ensure the integrated grounding spring maintains a clean metal-to-metal connection with the rail to establish a functional ground path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Convection Spacing:\u003c\/strong\u003e Provide a minimum vertical clearance of 50 mm above and below the module assembly to allow unrestricted natural convection cooling across the internal fanless heat-dissipation surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Configurations:\u003c\/strong\u003e Terminate discrete sensor and actuator wiring loops using stranded ferruled conductors. Separate high-voltage AC cables from the 24 VDC low-voltage I\/O lines by a minimum of 300 mm to suppress inductive noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Ground Connection:\u003c\/strong\u003e Clamp the external signal cables to the local low-impedance master copper ground bar within the enclosure to minimize electromagnetic interference across the high-speed input filter circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43881633841251,"sku":"FM221 00016747-10","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/31_b1e06847-2aff-4356-ba01-82a3afb52a74.jpg?v=1765335610","url":"https:\/\/www.autocontrolglobal.com\/ms\/products\/dio216-4-bachmann-m1-automation-system-datasheet-technical-manual","provider":"AutoControl Global","version":"1.0","type":"link"}