{"product_id":"ge-fanuc-ic693alg390f-analog-module-new-original-stock","title":"GE Fanuc IC693ALG390F Analog Module | New \u0026 Original Stock","description":"\u003ch2\u003eGE Fanuc IC693ALG390F Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693ALG390F\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693ALG390\u003c\/strong\u003e 2-Channel Analog Voltage Output Module, operates as a dedicated hardware component for converting digital values into analog signals within GE Fanuc Series 90-30 PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693ALG390F \/ IC693ALG390\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc (Emerson Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg (0.88 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e152.4 mm x 152.4 mm x 50.8 mm (6.0 in x 6.0 in x 2.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDetermined by active 18 to 30 VDC external field supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e-10 to +10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e2 analog voltage output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e2.5 mV per count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eFactory calibrated to 2.5 mV per count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 5 mV at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Offset\u003c\/td\u003e\n\u003ctd\u003e1 mV maximum from 0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e5 ms for all channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 V RMS field side to logic side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Supply\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC, 10% maximum ripple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693ALG390F\u003c\/strong\u003e interfaces with the parallel Series 90-30 backplane bus to transfer 12-bit digital profiles into internal digital-to-analog converter registers. The module maintains a deterministic 5 ms update rate across both voltage channels simultaneously, ensuring output tracking stability regardless of changes in backplane bus communication velocity or active network nodes. Galvanic isolation circuits rated at 1500 V RMS physically decouple the field terminal connections from the internal logic bus to suppress common-mode noise and safeguard the main PLC processor from field-side voltage spikes during complex system I\/O density scaling.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module draw its operational loop power directly from the 90-30 backplane?\u003c\/strong\u003e A: No. The internal digital-to-analog conversion circuits and analog output loops are powered via an external 18 to 30 VDC field supply connected to the terminal block. The module only draws a minimal logic-level initialization current from the backplane +5 VDC line.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens to the voltage outputs if the PLC enters a Stop mode or backplane communications fail?\u003c\/strong\u003e A: Upon a loss of backplane data transmission or CPU stop command, the digital-to-analog converters lose active register updates. The analog circuits drop the physical output values to a default safe state (0 VDC) to prevent downstream actuators or positioning loops from maintaining obsolete setpoints.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Power Isolation Requirements:\u003c\/strong\u003e De-energize both the backplane chassis power and the 24 VDC external field power loop before attaching or removing the field wiring connector terminal block to prevent active channel arcing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Terminal Termination:\u003c\/strong\u003e Connect the braided shield of the shielded twisted-pair signal cables directly to the chassis ground bar or designated shield terminals on the rack. Do not allow shield braids to remain floating or touch live electrical components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Voltage Specifications:\u003c\/strong\u003e Ensure the external DC supply provides a regulated voltage between 18 and 30 VDC. The supply must not exhibit a voltage ripple exceeding 10% to prevent degradation of the factory accuracy threshold (+\/- 5 mV).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44258830909539,"sku":"IC693ALG390F","price":420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/73_9ef6bede-5842-45d4-a8f7-8604d7203d73.jpg?v=1781490283","url":"https:\/\/www.autocontrolglobal.com\/ms\/products\/ge-fanuc-ic693alg390f-analog-module-new-original-stock","provider":"AutoControl Global","version":"1.0","type":"link"}