10004/1/1 Honeywell | Fault-Tolerant Automation Interface Module
10004/1/1 Honeywell | Fault-Tolerant Automation Interface Module
10004/1/1 Honeywell | Fault-Tolerant Automation Interface Module
/ 3

10004/1/1 Honeywell | Fault-Tolerant Automation Interface Module

  • Manufacturer: Honeywell

  • Part Number: 10004/1/1

  • Condition:New with Original Package

  • Product Type: Fault-Tolerant Automation Interface Module

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The HONEYWELL 10004/1/1 is a rack-plug communication module designed for Honeywell Fault Tolerant Automation (FTA) systems. It provides reliable, multi-channel serial connectivity between controller racks and field devices, enabling alarm forwarding, event logging, remote control, and historical data transport. Its fault-tolerant design ensures redundancy and high availability, while built-in diagnostics maintain communication integrity.

Technical Specifications

Parameter Details
Model 10004/1/1
Type FTA rack-plug communication module
Serial Ports 4 independent ports (RS‑232/RS‑422/RS‑485 selectable)
Data Integrity CRC checking and link diagnostics for error detection
Timing & Revisions Suffix 00701+ includes improved timing; some revisions meet updated Serial Communication Controller specs
Power Supply Powered from host rack/backplane; plug-in module form factor
Mounting FTA chassis rack with keyed connector and retention
Diagnostics Built-in diagnostics for communication health and link verification
Isolation Channel isolation per Honeywell FTA industrial design standards
Operating Temperature Industrial range; follow Honeywell installation guidelines
Humidity Industrial non-condensing range
Applications Protocol bridging, remote device linking, alarm/event forwarding, historical data transport, remote-control interfaces
Manufacturer Honeywell
Origin USA

FAQ

Q1: Is the 10004/1/1 module brand new?
A1: Yes, the Honeywell 10004/1/1 is full OEM, original, and brand-new.

Q2: How many serial communication ports does it have?
A2: The module provides 4 independent serial ports supporting RS‑232, RS‑422, or RS‑485.

Q3: Can this module be used for fault-tolerant communication?
A3: Yes, it includes redundant communication paths for high-availability FTA links.

Q4: What applications is the 10004/1/1 suitable for?
A4: It is ideal for alarm/event forwarding, remote control, protocol bridging, and historical data transfer.

Q5: Does it provide diagnostics for the communication links?
A5: Yes, CRC checking and built-in link diagnostics ensure robust communication reliability.

 