{"product_id":"10208-2-1-honeywell-fail-safe-controller-relay-card","title":"10208\/2\/1 Honeywell | Fail-Safe Controller Relay Card","description":"\u003ch3\u003e\u003cstrong\u003eHoneywell 10208\/2\/1 Fail-Safe Relay Output Module FSC System\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10208\/2\/1 (10208\/2\/1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-integrity Relay Output Module designed for use within the Honeywell Fail-Safe Controller (FSC) system. This module provides galvanic isolation and robust switching for safety-critical final control elements, such as emergency shutdown (ESD) valves, fire pumps, and motor starters. Unlike standard digital outputs, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10208\/2\/1 (10208\/2\/1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes dry contact relays to ensure a physical break in the circuit during a safety demand or system failure, adhering to strict SIL (Safety Integrity Level) requirements.\u003c\/p\u003e\n\u003cp\u003eWhile some legacy documentation occasionally cross-references varied part numbers, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10208\/2\/1 (10208\/2\/1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003especifically serves the Honeywell FSC architecture, providing reliable de-energize-to-trip functionality. Its design incorporates redundant internal circuitry and diagnostic feedback to monitor the health of the relay coils, ensuring that the safety function is performed even if a single component fails.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10208\/2\/1 (10208\/2\/1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for high-availability safety applications in harsh industrial environments.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10208\/2\/1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Fail-Safe Relay Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e: Honeywell FSC (Fail-Safe Controller)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e: Potential-free (Dry) Relay Contacts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e: 8 Independent Relay Channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Rating (Max)\u003c\/strong\u003e: 250 VAC \/ 30 VDC at 2.0 A (Resistive)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Load\u003c\/strong\u003e: 10 mA at 5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e: 2500 Vrms between logic and field circuitry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Power Consumption\u003c\/strong\u003e: 3.5 W (All relays energized)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e: \u0026lt; 10 ms (De-energization)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e: Per-channel LED for relay state and module health\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e: Standard FSC Rack Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -20°C to +70°C (-4°F to +158°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 135 x 186 x 119 mm (Rack standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 1.2 kg (2.65 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e: TUV SIL 3 Certified, CE, UL, CSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43012246470755,"sku":"10208\/2\/1","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/98.1_866ad833-7161-4f0e-ac2e-101ce9d36d2e.jpg?v=1771999943","url":"https:\/\/www.autocontrolglobal.com\/products\/10208-2-1-honeywell-fail-safe-controller-relay-card","provider":"AutoControl Global","version":"1.0","type":"link"}