{"product_id":"120vac-output-module-ic200mdl331-ge-fanuc-versamax","title":"120VAC Output Module IC200MDL331 GE Fanuc VersaMax","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC200MDL331\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-capacity discrete output interface for the VersaMax I\/O and PLC family. It provides eight independent, individually isolated channels designed to switch AC loads up to 120VAC. By providing total electrical separation between channels, this module allows engineers to control equipment powered by different AC phases or separate power sources within a single I\/O rack. It reliably drives high-current industrial actuators, including large motor starters, solenoids, and indicators.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 (Individually Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 Volts AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85 to 132 Volts AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current per Point\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 Amperes (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 Amperes (Maximum for 1 cycle)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/2 cycle (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Drop\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 Volts (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47 to 63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSnubber and MOV for each output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85 mA (Maximum from BIU supply)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Channel LEDs + 1 Module OK LED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Channel Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual isolation for all eight points eliminates the risk of cross-talk or fault propagation between circuits. This architecture enables the module to manage loads from distinct power grids or phases safely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile many PLC outputs limit current to 0.5A, the IC200MDL331 supports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2.0 Amperes per point\u003c\/strong\u003e. This robust capacity allows direct control of heavy-duty contactors without requiring intermediate interposing relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Transient Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery output contains a built-in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSnubber and MOV (Metal Oxide Varistor) circuit\u003c\/strong\u003e. These components clamp inductive voltage spikes and suppress high-frequency noise, significantly extending the operational life of both the module and the connected field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Diagnostic Visibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNine onboard LEDs provide immediate feedback. Eight dedicated channel LEDs track the ON\/OFF state of each output, while a central \"OK\" LED monitors the module's health, allowing maintenance teams to troubleshoot field-side issues without specialized software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersaMax Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module snaps onto any VersaMax I\/O carrier. This modular design permits hot-swapping (where the carrier and software allow) and reduces the total footprint in dense control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support DC loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC200MDL331 is strictly an AC output module designed for 85-132 VAC. Attempting to switch DC loads will result in the output failing to turn off due to the nature of the internal Triac\/AC switching components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the IC200MDL331 100% Brand New?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOriginal, Brand New, and Factory-Sealed\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE Fanuc (Emerson) units. Each module includes our standard 12-month industrial warranty.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module to switch different phases of 120VAC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Because every channel is individually isolated, you can switch different phases across the 8 channels without causing a short circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens during a high inrush current event?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module handles a maximum inrush of 20 Amps for a duration of half a cycle. This makes it ideal for starting inductive loads like small AC motors or large solenoid valves that require a high initial current to \"kick\" the mechanism.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44117376565347,"sku":"IC200MDL331","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/2._c39e0ccd-fbba-4629-bfe9-6425f2f9c488.jpg?v=1776154692","url":"https:\/\/www.autocontrolglobal.com\/products\/120vac-output-module-ic200mdl331-ge-fanuc-versamax","provider":"AutoControl Global","version":"1.0","type":"link"}