12HFA51A42H GE HFA Multicontact Auxiliary Relay
12HFA51A42H GE HFA Multicontact Auxiliary Relay
12HFA51A42H GE HFA Multicontact Auxiliary Relay
/ 3

12HFA51A42H GE HFA Multicontact Auxiliary Relay

  • Manufacturer: GE Fanuc

  • Part Number: 12HFA51A42H

  • Condition:New with Original Package

  • Product Type: Auxiliary Relays

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

GE 12HFA51A42H HFA Series Multicontact Auxiliary Relay

The GE 12HFA51A42H, also cataloged as the 12HFA51A42H Multicontact Auxiliary Relay, operates as a dedicated hardware component for multi-circuit switching and interlocking logic execution within power substation control and protection panels.

Suffix Breakdown & Model Matrix

Part Segment Code / Suffix Technical Definition
Basic Type 12 Product Generation / Frame Designation
Model Family HFA High-Speed Multicontact Auxiliary Relay Series
Construction 51 Hand-Reset / Self-Reset Operating Mechanism Variant
Contact / Coil A42H 125 VDC Coil Specification and 12-Contact Configuration

Hardware Specifications

Parameter Specification
Model 12HFA51A42H
Brand GE (General Electric)
Origin USA
Weight 1.0 kg (2.2 lbs)
Dimensions 12 in x 12 in x 12 in
Operating Temp -30 deg C to +65 deg C
Power Consumption +5 VDC at 6 A (Auxiliary logic power requirement)
Coil Voltage 125 VDC
Contact Capacity Up to 12 independent contact circuits
Reset Mechanism Self-resetting configuration
Application Target Protection, signaling, and interlocking control logic

Backplane Bus Communication & I/O Density Scaling

The auxiliary relay interfaces directly within hardwired relay panels and high-density control racks, enabling rapid signal multiplication across 12 independent contact paths. Contact actuation occurs instantaneously upon coil energization, delivering low latency and deterministic switching behavior across interlocking loops. Built-in contact geometry supports I/O density scaling inside protection cabinets while maintaining firmware flash compatibility with upstream digital protective relays for continuous status monitoring and system fault execution.

Frequently Asked Questions

Q: What operational behavior does the self-resetting mechanism provide during control loop actuation?

A: The self-resetting mechanism automatically returns all 12 contact circuits to their normal position once the 125 VDC coil voltage de-energizes, eliminating the need for manual physical reset flags or external electrical reset signals.

Q: How do the 12 independent contact circuits handle complex interlocking logic?

A: Each contact set operates electrically isolated from the others, allowing field engineers to mix control, alarm signaling, and trip isolation circuits across different DC voltage potential buses within the same physical relay module.

Field Installation Guidelines

Mount the relay vertically on standard panel cutout frameworks using approved mounting hardware to ensure structural stability under mechanical vibration. Run all high-voltage DC control wires through dedicated wiring troughs, maintaining strict physical separation between 125 VDC coil leads and low-voltage logic cables. Field technicians must verify coil supply polarity before applying power, ensure all terminal screws are torqued down securely to mitigate contact resistance, and confirm that panel grounding connections adhere to substation low-impedance grounding standards.