14-Point PLC Controller | GE Fanuc IC200UDD104 VersaMax Micro
14-Point PLC Controller | GE Fanuc IC200UDD104 VersaMax Micro
14-Point PLC Controller | GE Fanuc IC200UDD104 VersaMax Micro
/ 3

14-Point PLC Controller | GE Fanuc IC200UDD104 VersaMax Micro

  • Manufacturer: GE Fanuc

  • Part Number: IC200UDD104

  • Condition:New with Original Package

  • Product Type: Programmable Logic Controllers

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

GE Fanuc IC200UDD104 VersaMax Micro Controller

The GE Fanuc IC200UDD104-BG, also cataloged as the IC200UDD104 Micro Controller, operates as a dedicated hardware component for discrete logic control and high-speed pulse generation within GE VersaMax Micro PLC automation systems. The controller incorporates 8 discrete inputs operating at 24 VDC alongside 6 transistor outputs (2 high-current rated at 1.0 A and 4 low-current rated at 0.75 A). It runs on an external 24 VDC power supply, utilizing non-volatile flash memory for logic program execution and retaining parameters without battery power.

Suffix Breakdown & Model Matrix

The IC200UDD104 model designation identifies the base hardware layout of the 14-point VersaMax Micro Controller with a 24 VDC power and I/O interface. Hardware suffix codes such as -BA and -BG designate specific manufacturing revision levels, internal component variations, and updated firmware baseline releases. All suffix variations maintain identical terminal layout assignments, physical enclosure dimensions, operating voltage tolerances, and execution timing characteristics.

Hardware Specifications

Parameter Specification
Model IC200UDD104 (IC200UDD104-BA / IC200UDD104-BG)
Brand GE Fanuc / General Electric
Origin USA
Weight 0.30 kg (0.84 lbs)
Dimensions 92.5 mm x 82 mm x 60 mm
Operating Temp 0 deg C to +60 deg C
Storage Temp -40 deg C to +85 deg C
Power Consumption 4 W typical (19.2 to 30 VDC operating range)
Total Digital I/O 14 points (8 inputs, 6 outputs)
Digital Inputs 8 x 24 VDC (0 to 30 VDC range, 7.5 mA typical)
Digital Outputs 6 x 24 VDC transistor outputs
Output Ratings Q1-Q2: 1.0 A @ 24 VDC; Q3-Q6: 0.75 A @ 24 VDC
Inrush Current Q1-Q2: 8 A for 20 ms; Q3-Q6: 4 A for 20 ms
Isolation Voltage 1500 V RMS (field to logic), 500 V RMS (between groups)
High-Speed Capabilities PWM/PTO output up to 5 kHz; High-speed counter (Type A/B)
On-Board Adjustments 2 built-in analog potentiometers (8-bit resolution)

Firmware Flash Compatibility & I/O Density Scaling

The IC200UDD104 controller executes logic programs stored in internal non-volatile flash memory, retaining instruction sets across complete power loss without external battery retention circuits. Digital input response times are configurable between 0.5 ms and 20 ms to suppress noise artifacts across field sensor wiring. The unit supports direct high-speed pulse train output (PTO) generation up to 5 kHz alongside high-speed counter functions executing independently of CPU scan cycle variations. Internal optical coupling provides 1500 V RMS galvanic isolation to protect internal processor logic from external field transient spikes.

Frequently Asked Questions

Q: What are the output current limits for the transistor channels on the IC200UDD104?

A: Output channels Q1 and Q2 support up to 1.0 A continuous current at 24 VDC with an 8 A inrush capacity for 20 ms. Output channels Q3 through Q6 support up to 0.75 A continuous current at 24 VDC with a 4 A inrush capacity for 20 ms.

Q: How do the two integrated potentiometers function within the controller logic?

A: The two built-in analog potentiometers convert manual adjustment positions into internal 8-bit integer values (0 to 255) accessible directly via internal system registers in the logic application.

Q: What power supply range is required for proper operation of the module?

A: The module requires a nominal 24 VDC power supply operating within an allowable input range of 19.2 VDC to 30 VDC, maintaining a minimum hold-up time of 10 ms at 19.2 VDC.

Field Installation Guidelines

Mount the unit horizontally on a standard 35 mm DIN rail or attach it directly to an enclosure mounting plate using hardware screws through the integrated panel-mounting holes. Maintain a minimum clear space of 50 mm above and below the housing to allow adequate air circulation through the convection cooling vents.

Connect the primary 24 VDC system power to the designated power supply terminals, adhering strictly to polarity markings. Route 24 VDC input/output signal cables separately from AC power conductors and motor drive output leads to avoid inductive coupling. Connect the protective ground terminal directly to the central enclosure earth grounding bus using a short, low-impedance copper wire.