{"product_id":"170aao92100-schneider-modicon-momentum-analog-output-module","title":"170AAO92100 Schneider Modicon Momentum Analog Output Module","description":"\u003ch2\u003eSchneider 170AAO92100 Modicon Momentum Analog Output\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider 170AAO92100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e170AAO92100\u003c\/strong\u003e analog output module, operates as a dedicated hardware component for converting digital control values into precise voltage and current analog signals within Modicon Momentum distributed I\/O architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e170AAO92100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon Momentum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 single-ended channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ranges\u003c\/td\u003e\n\u003ctd\u003e+-10 V, +-5 V, 0-20 mA, 4-20 mA (configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit converted to 16-bit signed format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy at 25 deg C\u003c\/td\u003e\n\u003ctd\u003e+-0.15% FS (voltage), +-0.25% FS (current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy at 60 deg C\u003c\/td\u003e\n\u003ctd\u003e+-0.25% FS (voltage), +-0.45% FS (current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load\u003c\/td\u003e\n\u003ctd\u003eVoltage: \u0026gt;=1 kOhm, Current: \u0026lt;=750 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time\u003c\/td\u003e\n\u003ctd\u003e2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFail State\u003c\/td\u003e\n\u003ctd\u003eHold, reset-to-zero, reset-to-full-scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eInternal short-circuit, reverse polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-bus isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLED indicators for module status and fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e141.5 x 125 x 47.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.215 kg (0.474 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0-60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40-85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, IEC\/EN standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModicon Momentum Backplane Communication and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with the Modicon Momentum backplane bus, executing high-speed data transactions to maintain deterministic analog update cycles across distributed nodes. With 16 single-ended channels mapped into a compact physical footprint, the hardware optimizes cabinet real estate while supporting scalable I\/O expansion. Firmware flash compatibility ensures seamless integration with standard programming environments, maintaining stable channel-to-bus galvanic isolation and preventing ground-loop propagation across connected actuators and control valves.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum update time latency for the 170AAO92100 module across the backplane?\u003c\/p\u003e\n\u003cp\u003eA: The module executes complete channel refresh cycles within a deterministic update time of 2 ms.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module behave during a communication loss with the master PLC CPU?\u003c\/p\u003e\n\u003cp\u003eA: The module applies user-configurable fail-state behaviors, supporting hold-last-state, reset-to-zero, or reset-to-full-scale configurations to safeguard connected field actuators.\u003c\/p\u003e\n\u003cp\u003eQ: Can the output channels be configured independently for voltage and current ranges?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 16 single-ended channels support software-configurable ranges including +-10 V, +-5 V, 0-20 mA, and 4-20 mA.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module securely onto a standard DIN-rail or baseplate within an appropriately rated industrial enclosure to protect against dust and moisture ingress.\u003c\/li\u003e\n\u003cli\u003eEnsure proper shielding of analog signal cables. Terminate cable shields strictly at the enclosure ground bar to mitigate electromagnetic interference (EMI) and radio frequency interference (RFI).\u003c\/li\u003e\n\u003cli\u003eVerify power supply polarity prior to energizing the backplane to prevent internal circuit damage.\u003c\/li\u003e\n\u003cli\u003eMaintain minimum clearance distances from high-voltage power lines and variable frequency drives to preserve measurement accuracy and loop stability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43917228507235,"sku":"170AAO92100","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/227_9f2adeda-be8e-471b-9de4-72dec9fce677.jpg?v=1766716404","url":"https:\/\/www.autocontrolglobal.com\/products\/170aao92100-schneider-modicon-momentum-analog-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}