{"product_id":"2-port-foundation-fieldbus-h1-module-deltav-ve4017p0","title":"2-Port FOUNDATION Fieldbus H1 Module | DeltaV VE4017P0","description":"\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson VE4017P0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Alternate Part Numbers:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKJ3242X1-BA1\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12P2471X\u003c\/strong\u003e) is a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFOUNDATION Fieldbus H1 Interface Card\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDeltaV M-series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control System. This Series 2 module enables the integration of smart field instruments directly into the DeltaV environment. By utilizing digital bus technology, the VE4017P0 significantly reduces complex field wiring while unlocking advanced multivariable data and diagnostics from smart transmitters and valves. It serves as the bridge for synchronized control, allowing up to 16 devices per port to communicate over a single twisted-pair segment.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVE4017P0:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eComplete M-series H1 I\/O Interface Card and Simplex Terminal Block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKJ3242X1-BA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEmerson hardware manufacturing code for the Series 2 Interface Card.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12P2471X:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReference assembly number for the H1 electronics module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson Process Management\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVE4017P0\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeltaV M-Series (Series 2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFOUNDATION Fieldbus H1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDevice Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 16 devices per port (32 total per card)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports 1:1 Redundancy with Auto-sense\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSwitchover Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic, seamless failover\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM-series Controllers and I\/O Carriers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMassive Wiring Reduction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe H1 protocol allows the VE4017P0 to \"multi-drop\" up to 16 field devices on a single cable run. This reduces the number of home-run cables, cable trays, and terminal blocks required in the marshalling cabinet, lowering overall installation costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUninterrupted Redundant Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports 1:1 redundancy. The system constantly monitors the health of the active card; upon detecting a hardware fault, the redundant card assumes control automatically without losing a single communication packet or disrupting the process loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFull Smart Device Utilization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike traditional analog cards, the VE4017P0 accesses all parameters of a FOUNDATION Fieldbus device. It pulls status information, secondary variables, and configuration data into the DeltaV database, enabling advanced predictive maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSynchronized Bus Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe card executes the Link Active Scheduler (LAS) function, which synchronizes the execution of function blocks across the bus. This ensures that the control strategy remains deterministic and timing remains consistent for high-speed loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOpen Device Interoperability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe interface provides native support for third-party FOUNDATION Fieldbus devices. This allows engineers to select the best instruments for their specific application while maintaining seamless integration with the DeltaV host.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the VE4017P0 the same as the KJ3242X1-BA1?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Yes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVE4017P0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the system part number for the assembly (which includes the card and terminal block), while\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKJ3242X1-BA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the specific hardware model number printed on the card.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I hot-swap this card if it fails?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes. The M-series architecture allows you to remove and replace the H1 interface card while the system is powered. If you use a redundant pair, the process remains entirely undisturbed during the swap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does this card include the terminal block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: The VE4017P0 part number specifically includes both the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSeries 2 Interface Card\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSimplex Terminal Block\u003c\/strong\u003e. If you require a redundant terminal block, please contact us for the specific redundancy kit part number.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How many field devices can I realistically connect to one port?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: While the card supports up to 16 devices per port, the practical limit depends on the total current draw of the instruments and the length of the cable. Most engineers connect 8 to 12 devices to ensure sufficient power and signal margins.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":44109381369955,"sku":"VE4017","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/48_f1c4c566-934f-4ed6-b7ca-df151ccbd394.jpg?v=1775790116","url":"https:\/\/www.autocontrolglobal.com\/products\/2-port-foundation-fieldbus-h1-module-deltav-ve4017p0","provider":"AutoControl Global","version":"1.0","type":"link"}