{"product_id":"216gw62-hesg324008-abb-reg-216-ct-pt-signal-conditioner","title":"216GW62 HESG324008 ABB REG 216 CT\/PT Signal Conditioner","description":"\u003ch2\u003eABB 216GW62 REG 216 CT\/PT Signal Conditioner\u003c\/h2\u003e\n\u003cp\u003eConfigured for current and potential signal scaling and isolation in ABB REG 216 systems, the \u003cstrong\u003eABB 216GW62\u003c\/strong\u003e (\u003cstrong\u003e216GW62\u003c\/strong\u003e CT\/PT Signal Conditioner) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e216GW62 (Part Number: HESG324008)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSwitzerland \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg to 3.25 kg (configuration dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e280 mm x 180 mm x 81 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Operating Temperature Limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Component (Self-Powered from CT\/PT Loop)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eABB REG 216 Generator Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Role\u003c\/td\u003e\n\u003ctd\u003eCT\/PT Signal Scaling and Galvanic Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd\u003eDIN IP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85389099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Deterministic Network Interfacing\u003c\/h3\u003e\n\u003cp\u003eThe ABB 216GW62 scales high-level primary current transformer (CT) and potential transformer (PT) signals down to precise secondary levels for real-time acquisition across the ABB REG 216 generator protection system chassis. The module maintains magnetic core linearity during asymmetric fault current peaks, suppressing signal distortion before transferring analog waveforms across backplane processing buses. High-density wire windings and inter-channel isolation barriers eliminate cross-talk noise, ensuring low latency during high-speed differential algorithm execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ABB 216GW62 signal conditioner require an external auxiliary DC supply?\u003c\/p\u003e\n\u003cp\u003eA: No, the 216GW62 operates as a passive electromagnetic transformer assembly that derives energy directly from the measured CT\/PT field loops.\u003c\/p\u003e\n\u003cp\u003eQ: How does the 216GW62 module maintain signal accuracy during high-current grid faults?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates precision magnetic cores engineered to prevent magnetic saturation, allowing linear transformation of high fault currents to secondary processing levels.\u003c\/p\u003e\n\u003cp\u003eQ: What physical protection class does the module housing feature?\u003c\/p\u003e\n\u003cp\u003eA: The unit features a DIN IP30-rated metallic enclosure that guards internal windings against physical contact and environmental dust inside the panel.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eShort-circuit all current transformer (CT) secondary loops prior to touching terminals or disconnecting wiring on the ABB 216GW62 module to avoid lethal overvoltage induction. Verify that potential transformer (PT) supply breakers are open before making physical conductor connections.\u003c\/p\u003e\n\u003cp\u003eFirst, secure the 216GW62 chassis inside the REG 216 system enclosure using standard rack hardware. Confirm that panel chassis grounding jumpers establish a direct metal-to-metal connection with the station ground grid to dissipate common-mode electrical transients.\u003c\/p\u003e\n\u003cp\u003eSecond, connect field CT and PT wiring to the corresponding screw terminals on the module block according to the system schematic. Strip wiring back cleanly and torque terminal screws to standard factory specifications. Route analog input conductors through shielded twisted pairs, terminating shields at the designated single-point earth ground.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43838410850403,"sku":"216GW62 HESG324008","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/270.2_7e4f1c76-b551-4ad4-a698-326081c9ed85.jpg?v=1763103476","url":"https:\/\/www.autocontrolglobal.com\/products\/216gw62-hesg324008-abb-reg-216-ct-pt-signal-conditioner","provider":"AutoControl Global","version":"1.0","type":"link"}