{"product_id":"2mli-d28a-honeywell-brand-new-64-channel-optically-isolated-board","title":"2MLI-D28A Honeywell Brand New 64-Channel Optically Isolated Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 2MLI-D28A serves as a high-density, 64-point discrete digital input module engineered for the MasterLogic-200 programmable logic controller (PLC) platform and TDC 3000 distributed control system (DCS) architectures. This ultra-compact hardware block interfaces directly with field-side binary devices, collecting real-time binary state modifications from proximity switches, limit trips, safety interlocks, and dry contacts. Automation engineers deploy this module within large-scale process plants, manufacturing lines, and safety-critical monitoring stations to compress hundreds of diagnostic input lines into a concentrated control rack footprint.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2MLI-D28A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Architecture Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMasterLogic-200 PLC \/ TDC 3000 DCS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Density Digital Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Density\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 64 discrete channels (configuration dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Electrical Signal Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDry contact networks, passive switches, active 24 VDC loops\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 30 VDC continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTypical Operating Input Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 mA to 5 mA typical per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Processing Response Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than 10 milliseconds turn-on\/turn-off delay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Circuit Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDedicated optical optocoupler isolation per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Bus Power Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 VDC source derived directly via system backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Module Size Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 mm x 124 mm x 126 mm (W x H x D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Component Hardware Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.15 KG (0.33 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperational Temperature Thresholds\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +60 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Capabilities\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Operating Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 95 percent relative humidity, non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGlobal Industry Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE certified, UL508 listed, CSA approved, TUV safety validated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Sourcing Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New and Original in Factory Packing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch3\u003eUltra-Dense 64-Point Matrix Halves Control Panel Real Estate\u003c\/h3\u003e\n\u003cp\u003eThe 2MLI-D28A packs 64 independent digital input channels into a slim 22mm chassis width, maximizing the utility of standard MasterLogic-200 rack slots. This space-saving profile eliminates the need for multiple low-density 8-point or 16-point interface cards, reducing the total physical length of the PLC chassis assembly. By consolidating multi-channel wiring connections onto a single high-density front terminal header, panel fabricators reduce cabinet enclosure dimensions and decrease overall materials costs.\u003c\/p\u003e\n\u003ch3\u003ePer-Channel Optocouplers Terminate Common-Mode Electrical Noise\u003c\/h3\u003e\n\u003cp\u003eHigh-frequency interference from nearby variable frequency drives (VFDs), heavy welding equipment, and switching surges can distort binary signals. The 2MLI-D28A contains dedicated internal optical isolation circuits on every individual channel to stop this noise. By converting the incoming electrical current into a light pulse before data enters the logic bus, the optocouplers block stray high-voltage spikes, ground loops, and inductive feedback, maintaining data integrity in severe electromagnetic fields.\u003c\/p\u003e\n\u003ch3\u003eTrue Hot-Swappable Layout Prevents Process Interruption\u003c\/h3\u003e\n\u003cp\u003eContinuous-process sectors like petrochemical refining and water treatment cannot tolerate sudden control shutdowns during component maintenance. The 2MLI-D28A features specialized backplane connector pinning that supports hot-swapping under full system power. If a field circuit fault forces a module change, maintenance personnel can pull the active card and click a replacement unit into place without turning off the rack power supply, interrupting the central CPU logic execution, or dropping adjacent operational I\/O loops.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan the 2MLI-D28A accept alternating current (AC) field signals directly?\u003c\/p\u003e\n\u003cp\u003eNo. The input circuit topology uses solid-state DC sensing components designed exclusively for direct current lines up to 30 VDC. If your plant instruments utilize 120 VAC control circuits, you must run those connections through external interposing terminal relays to switch a clean 24 VDC pilot loop before running the final signal lines to this module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat field wiring connection method best prevents signal degradation on this high-density faceplate?\u003c\/p\u003e\n\u003cp\u003eBecause the module spaces 64 points across a narrow 22mm panel front, Honeywell recommends using multi-conductor shielded ribbon cables or pre-fabricated terminal blocks paired with dedicated wiring harnesses. Proper grounding of the external cable shields at a centralized panel ground bar vents stray electromagnetic energy safely away from the card's input logic pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this module require specialized setup software to change between dry contact and active 24 VDC operation?\u003c\/p\u003e\n\u003cp\u003eNo hardware modifications or software parameter changes are required. The input circuits auto-sense incoming current within the 3 mA to 5 mA envelope. To mix input styles, arrange your external power supply lines so that dry contacts route the necessary 24 VDC loop potential directly into the corresponding channel terminal point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43846834356323,"sku":"2MLI-D28A","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/261_300e01e3-35bc-400d-ac30-b10bdefa2357.jpg?v=1763717964","url":"https:\/\/www.autocontrolglobal.com\/products\/2mli-d28a-honeywell-brand-new-64-channel-optically-isolated-board","provider":"AutoControl Global","version":"1.0","type":"link"}