{"product_id":"2mlp-ac23-honeywell-masterlogic-200-power-supply-module","title":"2MLP-AC23 Honeywell MasterLogic-200 Power Supply Module","description":"\u003ch2\u003eHoneywell 2MLP-AC23 MasterLogic-200 Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 2MLP-AC23\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2MLP-AC23\u003c\/strong\u003e Industrial Power Supply, operates as a dedicated hardware component for 5 VDC power distribution within MasterLogic-200 PLC and DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2MLP-AC23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e125 x 50 x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e170-264 VAC input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e5 VDC @ 8.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Power Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e2MLP-AC23\u003c\/strong\u003e utilizes high-efficiency switching architecture to maintain a stable 5 VDC output, which supports deterministic backplane bus communication velocity across the MasterLogic-200 rack. The module incorporates built-in surge voltage protection limits to mitigate the effects of AC line transients common in heavy industrial facilities. By providing clean, regulated power, the unit ensures that processor execution and I\/O density scaling remain unaffected by fluctuations in input voltage. Furthermore, the module features thermal heat sink dissipation profiles designed for high-density DIN-rail mounting stability, ensuring long-term hardware durability even when operated at maximum output current loads in confined control panels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 2MLP-AC23 support redundancy if used in parallel with another supply?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed for independent supply; parallel operation requires specific diode-ORing circuitry or dedicated power-sharing modules to prevent back-feeding and hardware damage.\u003c\/p\u003e\n\u003cp\u003eQ: How does the power supply react to instantaneous input voltage drops?\u003c\/p\u003e\n\u003cp\u003eA: The module maintains output stability during interruptions lasting up to 10 ms; any drop exceeding this duration may cause the MasterLogic-200 controller to initiate a warm-start or reset sequence.\u003c\/p\u003e\n\u003cp\u003eQ: Is the built-in input fuse field-replaceable?\u003c\/p\u003e\n\u003cp\u003eA: The built-in UL standard slow-blow fuse is internal. If the fuse blows, it indicates a catastrophic failure within the power stage, and the module requires physical replacement rather than field repair.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the power supply in a clean, ventilated enclosure on a standard DIN rail. Maintain at least 50 mm of clearance above and below the unit to facilitate convective thermal dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use 0.75-2 mm squared conductors for AC inputs. Secure all connections using RAV 1.25-3.5 or RAV 2-3.5 compressed terminals to ensure low-resistance paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the protective earth terminal to the main system ground bus. This is mandatory for surge protection effectiveness and electromagnetic compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidation:\u003c\/strong\u003e Before connecting the DC output to the rack backplane, verify that the output LED is illuminated and that the voltage measures 5 VDC (+\/- 2%) using a calibrated multimeter.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43853893009507,"sku":"2MLP-AC23","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/274.1_86e1fe3d-418e-4125-b818-1d49eb385886.jpg?v=1764056941","url":"https:\/\/www.autocontrolglobal.com\/products\/2mlp-ac23-honeywell-masterlogic-200-power-supply-module","provider":"AutoControl Global","version":"1.0","type":"link"}