{"product_id":"3300-10-02-02-00-bently-nevada-115v-220v-ac-rack-power","title":"3300\/10-02-02-00 Bently Nevada 115V\/220V AC Rack Power","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/10 (Part Number 3300\/10-02-02-00 \/ 78422-01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the foundational power source for the Bently Nevada 3300 Series Machinery Monitoring System. This full-height module occupies the left-most slot (Position 1) of the rack and converts standard AC line voltage into the regulated DC power required by all installed monitors and transducers. A single 3300\/10 module provides sufficient current to drive a fully populated 12-slot rack, ensuring consistent operation of critical vibration and position monitoring loops. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein factory packaging.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: 3300\/10-AA-BB-CC\u003c\/h3\u003e\n\u003cp\u003eThe 3300\/10 uses specific alphanumeric codes to designate input voltage range and agency certifications.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAA: 02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh Voltage AC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConfigurable for 115 Vac or 220 Vac operation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBB: 02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCSA\/NRTL\/C (Class 1, Div 2) certified for hazardous areas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCC: 00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafety Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard factory testing and documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 to 125 Vac, or 190 to 250 Vac (Switchable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRegulated DC for modules and Proximitor sensors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 A Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +65°C (32°F to +149°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35.6 cm x 4.8 cm x 24.1 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg ( 2.7 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Line Noise Filtration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 3300\/10 features a built-in industrial-grade line filter. This hardware layer intercepts electrical transients and electromagnetic interference (EMI) from the plant grid, preventing supply-side noise from corrupting delicate vibration data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Voltage Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineers can easily toggle the module between 115 Vac and 220 Vac by adjusting an internal jumper cable. This flexibility allows for global deployment across different regional power standards using a single part number.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFull Rack Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike lower-tier supplies, the robust thermal design of the 3300\/10 handles the maximum load of 12 monitor modules plus transducers without requiring secondary or auxiliary power supplies in standard configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module carries CSA\/NRTL\/C approvals, ensuring safe operation in Class 1, Division 2 environments typical of oil refineries and chemical processing plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use the 3300\/10 in a 3500 Series rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The 3300\/10 is physically and electrically incompatible with the 3500 system. It fits only the mechanical backplane of the Bently Nevada 3300 Series. For 3500 racks, you must use the 3500\/15 power supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I change the input voltage from 115 Vac to 220 Vac?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou must perform the voltage selection manually by adjusting a designated cable\/jumper on the power supply module before inserting it into the rack. Always verify the voltage setting matches your local mains to prevent hardware damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 3300\/10 provide power to the proximity probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndirectly, yes. The 3300\/10 provides the regulated DC voltage to the monitor modules (such as the 3300\/16 or 3300\/20), which then distribute the necessary negative voltage to the field-mounted Proximitor® sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this power supply \"Hot-Swappable\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. In a standard single-supply 3300 rack, removing the 3300\/10 will immediately power down the entire machinery protection system. Only remove or install the module when the rack is either bypass-protected or during a scheduled machine outage.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44177249239139,"sku":"3300\/10-02-02-00","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/1.1_5f36c96f-fb03-4437-a4b7-310b02628c99.jpg?v=1778654813","url":"https:\/\/www.autocontrolglobal.com\/products\/3300-10-02-02-00-bently-nevada-115v-220v-ac-rack-power","provider":"AutoControl Global","version":"1.0","type":"link"}