{"product_id":"330908-bently-nevada-3300-xl-nsv-eddy-current-sensor","title":"330908 Bently Nevada 3300 XL NSV Eddy Current Sensor","description":"\u003ch2\u003eGE IS200STAIH2AAA Mark VIe Series\u003c\/h2\u003e\n\u003cp\u003eConfigured for signal termination and interface conditioning in Mark VI\/Mark VIe control system networks, the \u003cstrong\u003eGE IS200STAIH2AAA\u003c\/strong\u003e (\u003cstrong\u003eIS200STAIH2\u003c\/strong\u003e Analog Input Terminal Board) provides direct physical\/electrical execution. The module terminates field analog input signals, including 4-20 mA current loops, plus minus 5 VDC, and plus minus 10 VDC voltage inputs, transmitting the conditioned data directly to the respective I\/O packs.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe catalog number configuration follows a defined component structural matrix:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIS200\u003c\/strong\u003e: Standard internal printed circuit board assembly identifier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSTAI\u003c\/strong\u003e: Simple Analog Input Terminal Board functional module group designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eH2\u003c\/strong\u003e: Hardware group variant matching specific terminal configurations and channel density limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAAA\u003c\/strong\u003e: Artwork, assembly, and functional revision level matching compatibility baselines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200STAIH2AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States of America (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e33 cm x 17.8 cm x 5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA \/ plus minus 5 VDC \/ plus minus 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurden Resistor\u003c\/td\u003e\n\u003ctd\u003e250 Ohm for current inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Gauge\u003c\/td\u003e\n\u003ctd\u003e12 to 24 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTorque Rating\u003c\/td\u003e\n\u003ctd\u003e0.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-system and channel-to-channel isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling \u0026amp; Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IS200STAIH2AAA establishes a high-density passive architecture optimizing signal distribution across 16 parallel input channels. By implementing fixed 250 Ohm burden resistors, the assembly translates incoming current variables into local voltage equivalents for fast digitization by adjacent I\/O processing packs. System integration relies on direct connection protocols to the active controller platform via deterministic internal backplane communication structures, mitigating propagation delays and securing precise signal sampling rates without software-driven translation layers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IS200STAIH2AAA board contain active firmware that requires flash programming?\u003c\/p\u003e\n\u003cp\u003eA: No. The IS200STAIH2AAA is a passive analog input terminal board containing termination blocks, low-pass analog filtering components, and internal routing traces. It does not contain programmable microcontrollers or onboard firmware flash matrices; configuration parameters are managed solely inside the attached digital I\/O pack.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle the common-mode voltage present across independent field transmitters?\u003c\/p\u003e\n\u003cp\u003eA: Galvanic and electrical safety boundaries are sustained via channel-to-system and channel-to-channel isolation networks. The board infrastructure rejects common-mode noise voltages through hardware-based low-pass analog filtering, preventing crosstalk and shielding the primary controller networks from field-induced electrical surges.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Infrastructure:\u003c\/strong\u003e Install the board onto the designated DIN rail or control rack frame inside the enclosure panel, ensuring all mechanical latching mechanisms are engaged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Conductor Specifications:\u003c\/strong\u003e Use field wiring cables within the certified 12 to 24 AWG dimension range. Tighten all terminal screws strictly to the specified 0.5 Nm torque specification to eliminate high-resistance contact vectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Matrix:\u003c\/strong\u003e Strip external analog loop cables at the designated entry point and clamp the overall shield braids securely to the primary instrument chassis ground bus bar to prevent high-frequency noise injection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44272800202851,"sku":"IS200STAIH2AAA","price":420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/88._a3f79a91-cf42-455a-914f-e44d91ff4cfe.jpg?v=1782090937","url":"https:\/\/www.autocontrolglobal.com\/products\/330908-bently-nevada-3300-xl-nsv-eddy-current-sensor","provider":"AutoControl Global","version":"1.0","type":"link"}