350‑E‑P0‑G0‑H‑E‑E‑C‑P‑SN‑N‑N | GE Multilin Feeder Protection Relay
Manufacturer: GE Fanuc
-
Part Number: 350-E-P0-G0-H-E-E-C-P-SN-N-N
Condition:New with Original Package
Product Type: Multilin Feeder Protection Relay
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
GE Multilin 350‑E‑P0‑G0‑H‑E‑E‑C‑P‑SN‑N‑N Feeder Protection Relay – Product Description
Overview
The GE Multilin 350‑E‑P0‑G0‑H‑E‑E‑C‑P‑SN‑N‑N is a digital feeder protection relay designed for advanced protection, control, and monitoring of electrical feeders. Moreover, it provides integrated arc flash protection, high-speed diagnostics, and communication features, making it suitable for both utility substations and industrial power distribution systems. This model offers flexibility for feeders without internal CT inputs, allowing cost-effective deployment in various configurations.
Technical Specifications
Current Inputs:
-
Phase CTs: Not included (P0 configuration)
-
Ground CTs: Not included (G0 configuration)
Protection Functions:
-
Overcurrent protection (phase/ground if external CTs are connected)
-
Breaker failure protection
-
Thermal overload protection
-
Voltage and frequency monitoring (optional)
Control & Outputs:
-
Electromechanical relay outputs for trip, alarm, and control functions (H)
-
Breaker control logic with interlocks (C)
-
Programmable logic and virtual inputs (P)
-
Manual commands via front panel or SCADA
Communication Protocols:
-
Dual Ethernet ports (E‑E)
-
Modbus RTU/TCP
-
DNP3.0
-
IEC 60870‑5‑103
Recording & Diagnostics:
-
Event recording with timestamp
-
Waveform capture for fault analysis
-
Preventive maintenance and self-diagnostics
Power Supply:
-
Universal AC/DC supply (88–300 VDC / 70–265 VAC)
Environmental Ratings:
-
Operating temperature: –40 °C to +70 °C
-
Storage temperature: –40 °C to +85 °C
-
EMC immunity per IEC 61000 standards
Physical Specifications:
-
Compact panel-mount design
-
weight: 3 kg
-
Dimensions: 220 × 180 × 200 mm
FAQ
Q1: Does this relay include phase and ground CTs?
No, the P0-G0 configuration excludes internal CTs, but external CTs can be connected.
Q2: Can it communicate with SCADA systems?
Yes, it supports dual Ethernet, Modbus RTU/TCP, DNP3.0, and IEC 60870‑5‑103 protocols.
Q3: What is the operating temperature range?
The relay operates reliably between –40 °C and +70 °C.
Q4: Does it support arc flash protection?
Yes, integrated arc flash mitigation enhances operational safety.
Q5: Is event recording available?
Yes, the relay captures events with timestamps and waveform data for fault analysis.