{"product_id":"36-terminal-box-style-i-o-carrier-ge-fanuc-ic200chs022n","title":"36-Terminal Box Style I\/O Carrier | GE Fanuc IC200CHS022N","description":"\u003ch2\u003eGE Fanuc IC200CHS022N VersaMax Box Style I\/O Carrier\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200CHS022N\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200CHS022\u003c\/strong\u003e Box-Style I\/O Carrier, operates as a dedicated hardware component for field signal termination and backplane bus connection within VersaMax automation platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200CHS022N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eRefer to device label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg (0.75 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 mm x 66.8 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive carrier (no active logic draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Terminals\u003c\/td\u003e\n\u003ctd\u003e36 box-style \/ spring-clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Capacity\u003c\/td\u003e\n\u003ctd\u003e0.5 to 2.5 mm2 (AWG #14 to #22 single, up to AWG #18 dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e300 V AC\/DC max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Current Rating\u003c\/td\u003e\n\u003ctd\u003e10 A max per terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail or sub-panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe carrier module links adjacent field nodes using integrated carrier-to-carrier connectors, maintaining high backplane bus communication velocity across the VersaMax local rail. Integrated internal copper paths channel logic power, ground references, and field signals directly to the plugged-in I\/O module interface. With support for 36 discrete field wiring points within a compact footprint, the unit optimizes I\/O density scaling inside control enclosures while maintaining physical channel-to-channel isolation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can an I\/O module be removed from the IC200CHS022N carrier while field wiring remains connected?\u003c\/p\u003e\n\u003cp\u003eA: You can disconnect and replace the active I\/O module directly from the carrier face without disturbing the 36 field wiring terminals, provided field power feeds are isolated to prevent arcing across backplane pins.\u003c\/p\u003e\n\u003cp\u003eQ: What grounding precautions must be taken during DIN rail installation to prevent EMC interference?\u003c\/p\u003e\n\u003cp\u003eA: You must ensure the DIN rail itself connects directly to protective earth (PE) with low impedance, as the metallic grounding clip on the back of the carrier relies on physical rail contact for EMC shielding.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum current capacity supported per terminal block connection?\u003c\/p\u003e\n\u003cp\u003eA: Each individual terminal supports a maximum rating of 10 A at 300 V AC\/DC; circuits exceeding 10 A require external interposing power relays.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the carrier horizontally onto a standard 35 mm DIN rail or secure it to the sub-panel using mounting screws through the dedicated chassis slots. Route incoming signal wires to the 36 terminals, stripping wire insulation appropriately for solid or stranded copper conductors ranging from AWG #14 to #22. Ensure adjacent carrier units snap tightly together to engage the side-mounted carrier-to-carrier backplane bus connectors before seating the target VersaMax I\/O module onto the top socket.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44458397302883,"sku":"IC200CHS022N","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/480._ce062fa6-63b7-4fe4-8184-cd0e09b62003.jpg?v=1786348322","url":"https:\/\/www.autocontrolglobal.com\/products\/36-terminal-box-style-i-o-carrier-ge-fanuc-ic200chs022n","provider":"AutoControl Global","version":"1.0","type":"link"}