{"product_id":"3bse008560r1-abb-tb810-fiber-optic-modulebus-connector","title":"3BSE008560R1 ABB TB810 Fiber Optic Modulebus Connector","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB TB810 (3BSE008560R1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the primary fiber optic interface for the S800 I\/O system. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal unit enables the expansion of the Modulebus to remote I\/O clusters, transcending the distance limitations of standard electrical cabling. By converting electrical bus signals into optical pulses, the TB810 facilitates high-speed, interference-free data exchange between the central controller and distributed I\/O stations in complex industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe TB810 utilizes a compact form factor designed for seamless integration into the S800 I\/O station base.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTB810\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrder Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BSE008560R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModulebus Optical Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMedium\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFiber Optic (Plastic or HCS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed Modulebus Sync\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 mm x 40 mm x 20 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.035 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-power passive-logic interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS EU Directive 2011\/65\/EU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5. Small Equipment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe TB810 Optical Port solves critical signal integrity and architecture challenges in automated facilities:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Electromagnetic Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBecause it uses fiber optic transmission, the TB810 eliminates data corruption caused by high-voltage motors, frequency converters, or lightning strikes. This makes it indispensable for applications in power plants and heavy manufacturing zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe optical link provides a complete electrical break between I\/O clusters. This prevents ground loops and ensures that a fault in one remote station does not propagate through the bus to the main processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Compact Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeasuring only 40mm x 40mm, the module installs directly into the I\/O station without requiring additional DIN rail space or complex mounting hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistance Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike copper Modulebus connections limited to a few meters, the TB810 allows engineers to position I\/O clusters dozens of meters away from the controller, optimizing floor space and reducing local wiring costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the TB810 compatible with both plastic and HCS fiber?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The TB810 supports standard plastic optical fiber (POF) for short distances and Hard Clad Silica (HCS) fiber for longer runs, providing flexibility based on your specific plant layout.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a separate power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The TB810 draws its necessary operating power directly from the Modulebus connection on the I\/O station base, simplifying the power distribution scheme within your cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the signal strength of the optical link?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TB810 integrates with the standard ABB diagnostics suite. You can monitor the communication health and signal integrity via the Control Builder M software or the diagnostic LEDs located on the associated CI810\/CI820 Fieldbus Communication Interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I hot-swap the TB810 during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the S800 system supports many hot-swappable components, removing the TB810 will break the Modulebus ring or link, causing all downstream I\/O modules to lose communication. Always perform replacements during a scheduled maintenance window or ensure system redundancy is active.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44172382142563,"sku":"TB810","price":520.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/484._7354544b-df2a-4e50-9e2c-d9ecc5d263b6.jpg?v=1778553697","url":"https:\/\/www.autocontrolglobal.com\/products\/3bse008560r1-abb-tb810-fiber-optic-modulebus-connector","provider":"AutoControl Global","version":"1.0","type":"link"}