{"product_id":"3bse056767r1-abb-ci871k01-industrial-network-interface","title":"3BSE056767R1 ABB CI871K01 Industrial Network Interface","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB CI871K01 (Part Number: 3BSE056767R1) functions as a high-performance PROFINET IO Interface Kit for ABB System 800xA and AC 800M process control architectures. This industrial communication package bridges processing units and decentralized field instruments. It allows AC 800M controllers to operate as native PROFINET IO controllers, transmitting deterministic data packets to distributed I\/O blocks, variable speed drives, and intelligent electronic devices (IEDs).\u003c\/p\u003e\n\u003cp\u003eWe deliver this hardware assembly as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original, and factory-sealed\u003c\/strong\u003e. The complete kit includes the CI871 Communication Interface module alongside its matching TP867 interface baseplate, backed by our 12-month industrial hardware warranty.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCI871K01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BSE056767R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFINET IO Interface Kit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 800M controllers (PM861, PM864, PM866, PM891)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFINET IO (Ethernet-based)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Transmission Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10\/100 Mbps Full Duplex auto-negotiation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Connectors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x RJ45 ports (located on the TP867 baseplate)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 12 modules per controller via CEX-Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e160 mA typical at 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.8 W typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHot-Swap Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLive operational hot-swapping allowed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e186 mm H x 59 mm W x 127.5 mm D\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Structural Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.7 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 degrees C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCorrosion Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 harsh environment certification (ISA 71.04)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 rating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mm DIN rail via TP867 baseplate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccelerates Distributed Device Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module processes Ethernet-based PROFINET protocols at 10\/100 Mbps in full duplex mode. This dedicated speed loop feeds real-time digital field device data back to the primary AC 800M processor without creating data bus bottlenecks during high-density I\/O polling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSurvives Corrosive Chemical Vapor Atmospheres:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eISA 71.04 G3-compliant conformal coating protects the interior multi-layer printed circuit boards. This chemical shielding blocks airborne sulfur, moisture, and chlorine vapors from oxidizing copper tracks in wastewater treatment facilities and petrochemical refineries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePermits Zero-Downtime Hot-Swapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in backplane power isolation circuits allow technicians to insert or remove the active CI871 interface module while the system runs live. This feature lets you swap components without halting neighboring automation tracks or dropping the host CEX-Bus network power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminates External Network Hub Expenses:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe underlying TP867 baseplate integrates a built-in dual-port RJ45 Ethernet switch matrix. This port pairing allows engineers to daisy-chain network lines directly from module to module inside the cabinet layer, saving physical rail space by skipping standalone Ethernet switch installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich specific ABB controller variants accept the CI871K01 interface kit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CI871K01 matches the hardware configuration and signaling of the ABB AC 800M controller series. It links directly with PM861, PM864, PM866, and PM891 processing models through the integrated side-attaching CEX-Bus system rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat installation sequence prevents port misalignment or backplane faults?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMount the TP867 baseplate firmly onto the standard 35mm DIN rail first, locking it into position next to the controller module or existing CEX-Bus extensions. Slide the CI871 interface housing downward into the baseplate guides until the internal dual pin assemblies mesh completely into the backplane, then lock the retention latches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require independent external grounding straps inside the panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The TP867 baseplate features built-in metallic grounding clips that snap directly onto the metal DIN rail frame. This mechanical connection establishes a low-impedance ground path that drains off electromagnetic noise automatically, provided you ground the DIN rail to the primary cabinet earth terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44189351215203,"sku":"CI871K01 3BSE056767R1","price":340.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/141_c1d952f7-9431-4109-823f-19fc50b41b7d.jpg?v=1779180566","url":"https:\/\/www.autocontrolglobal.com\/products\/3bse056767r1-abb-ci871k01-industrial-network-interface","provider":"AutoControl Global","version":"1.0","type":"link"}