{"product_id":"4-point-field-control-analog-module-ge-fanuc-ic670alg320","title":"4 Point Field Control Analog Module | GE Fanuc IC670ALG320","description":"\u003ch2\u003eGE Fanuc IC670ALG320 Field Control Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for precise analog signal execution in Field Control systems, the \u003cstrong\u003eGE Fanuc IC670ALG320\u003c\/strong\u003e (\u003cstrong\u003eIC670ALG320\u003c\/strong\u003e Analog Module) provides direct physical signal processing across 4 isolated output channels. It converts digital words from the Bus Interface Unit backplane into proportional 0-20 mA, 4-20 mA, 0-10 VDC, or 0-12.5 VDC control signals to drive field actuators and valves.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670ALG320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.48 kg (1.06 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Field Control Module Format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C (Storage: -40 deg C to +85 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.4 W minimum; 4.3 W maximum (20-29 VDC external supply, 180 mA max operating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBIU Power Draw\u003c\/td\u003e\n\u003ctd\u003e51 mA maximum from Bus Interface Unit power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e4 single-ended output channels (1 single group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA, 0-10 VDC, 0-12.5 VDC source outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Resolution\u003c\/td\u003e\n\u003ctd\u003e12-bit (4.0 uA @ 4-20 mA; 50 uA @ 0-20 mA; 2.5 mV @ 0-10 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e60 us per channel typical (at 1 MHz clock)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e+\/-0.002% of value per deg C typical (+\/-0.005% max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC for 1 min (user-to-logic\/frame ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC670ALG320 maintains backplane bus communication velocity across local expansion racks while providing high I\/O density scaling in control enclosures. Integrated optical isolation barriers protect internal logic circuits against ground loops and field transients, ensuring deterministic output updates without corrupting system scan cycles. Firmware flash compatibility across parent CPU units guarantees stable backplane handshake operations during continuous 12-bit digital-to-analog conversions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the external power supply requirements for the IC670ALG320 module?\u003c\/p\u003e\n\u003cp\u003eA: The module requires an external power supply of 20 VDC to 29 VDC with a maximum ripple of 5%, consuming up to 180 mA during active operation.\u003c\/p\u003e\n\u003cp\u003eQ: How does the IC670ALG320 isolate field signals from local backplane logic?\u003c\/p\u003e\n\u003cp\u003eA: Optical isolation barriers provide galvanic isolation rated at 250 VAC continuous and 1500 VAC for 1 minute between field outputs, logic circuits, and frame ground.\u003c\/p\u003e\n\u003cp\u003eQ: What current draw does the IC670ALG320 place on the local Bus Interface Unit?\u003c\/p\u003e\n\u003cp\u003eA: The module draws a maximum of 51 mA directly from the 5 VDC internal logic supply of the Bus Interface Unit backplane.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDe-energize primary backplane power and external 24 VDC field power before inserting or removing the module from its terminal base.\u003c\/li\u003e\n\u003cli\u003eSecure field cabling to the removable terminal block using shielded twisted-pair wires to suppress noise on analog loops.\u003c\/li\u003e\n\u003cli\u003eConnect cable shielding to panel earth ground at one end only to prevent ground loop currents across isolated output circuits.\u003c\/li\u003e\n\u003cli\u003eVerify channel output mode selection prior to applying external power to connected actuators or positioning valves.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate enclosure ventilation to prevent ambient operating temperatures from exceeding +60 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44511126782051,"sku":"IC670ALG320","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/147._4ec62f02-ff60-408f-8119-f1ea47f4e11a.jpg?v=1787641924","url":"https:\/\/www.autocontrolglobal.com\/products\/4-point-field-control-analog-module-ge-fanuc-ic670alg320","provider":"AutoControl Global","version":"1.0","type":"link"}