{"product_id":"48-channel-discrete-input-module-is230tdbth6a-ge-fanuc","title":"48-Channel Discrete Input Module |  IS230TDBTH6A | GE Fanuc","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS230TDBTH6A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Discrete Input Terminal Board (TDBT) specifically engineered for the GE Speedtronic Mark VIe control system. This module serves as the primary physical termination point for field-side dry contacts, providing seamless integration for turbine auxiliary status signals, limit switches, and relay feedback. Designed for high-availability industrial environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS230TDBTH6A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that field signals are accurately conditioned and isolated before being processed by the controller.\u003c\/p\u003e\n\u003cp\u003eUnlike standard interface boards, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS230TDBTH6A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures integrated hardware filtering to eliminate \"contact bounce\" and high-frequency electrical noise, which are common in power generation facilities. This ensures the integrity of the data broadcast across the control network. The board is optimized for simplex configurations but maintains the rugged standards required for critical infrastructure, supporting continuous operation across a broad thermal range.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS230TDBTH6A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Platform\u003c\/strong\u003e: GE Mark VIe Control System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: Discrete Contact Input Termination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Capacity\u003c\/strong\u003e: 48 high-density input channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e: Dry contact status signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExcitation Voltage\u003c\/strong\u003e: 24 VDC nominal (Supports standard turbine auxiliary DC levels)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Type\u003c\/strong\u003e: Per-channel optical isolation for superior noise immunity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Conditioning\u003c\/strong\u003e: Built-in RC filtering for contact bounce suppression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Interface\u003c\/strong\u003e: Two large 48-point screw-type terminal blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -20 °C to +60 °C (-4 °F to 140 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40 °C to +85 °C (-40 °F to 185 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Rack or cabinet-base mounting within Mark VIe enclosures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 170 mm x 90 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReliability Standard\u003c\/strong\u003e: IEC 61326-1 (EMC Compliance)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication \u0026amp; System Strategy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS230TDBTH6A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis typically utilized in the Mark VIe cabinet to monitor non-redundant or auxiliary turbine systems. It acts as the bridge between the field wiring and the I\/O pack. By centralizing 48 channels onto a single board, it significantly reduces the wiring footprint and simplifies troubleshooting. This board is essential for maintaining the E-E-A-T principles of a control system, providing a trustworthy and authoritative hardware layer that handles raw field data with precision.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IS230TDBTH6A handle 125 VDC inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS230TDBTH6A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eboards are typically optimized for 24 VDC excitation. For 125 VDC applications, please verify the specific hardware group or consider the TDBTH2\/TDBTH4 variants designed for higher voltage thresholds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this board hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the terminal board itself is a passive physical interface, the I\/O pack connected to it is hot-swappable. However, removing the terminal board connections will interrupt signal flow for all 48 channels, which may result in a system alarm or trip depending on the logic configuration.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44074236706915,"sku":"IS230TDBTH6A","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/349._55095bce-5631-4e5d-a5a2-5d59e4208c51.jpg?v=1774230031","url":"https:\/\/www.autocontrolglobal.com\/products\/48-channel-discrete-input-module-is230tdbth6a-ge-fanuc","provider":"AutoControl Global","version":"1.0","type":"link"}