{"product_id":"51199588-100-honeywell-analog-input-module-tdc-3000","title":"51199588-100 Honeywell Analog Input Module TDC 3000","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 51199588-100 operates as a high-precision Analog Input Module within Honeywell TDC 3000 Distributed Control Systems (DCS). This rack-mounted card executes continuous, real-time data acquisition from field transmitters, flow meters, and industrial sensors. By converting standard analog field instrumentation readings into deterministic digital values, it feeds accurate process telemetry straight to central control processors.\u003c\/p\u003e\n\u003cp\u003eWe deliver this product as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and factory original\u003c\/strong\u003e. The module ships inside its native factory-sealed packaging, remains in pristine, uncommissioned stock, and includes a full 12-month industrial hardware warranty.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51199588-100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell TDC 3000 DCS and Legacy Platforms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Signal Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-20 mA, 0-10 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple independent analog inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChassis Rack-mounted\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Power Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +60 degrees C (32 to 140 degrees F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e170 x 80 x 45 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBrand new, original factory stock\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminates Signal RFI and EMI Jitter:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnboard differential filtering circuitry isolates individual input channels. This robust shielding architecture blocks radio frequency interference (RFI) and electromagnetic interference (EMI) caused by heavy plant switchgear, maintaining stable 4-20 mA process readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplifies High-Density Cluster Upgrades:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe space-saving 170 x 80 x 45 mm form factor plugs straight into standard TDC 3000 chassis files. This physical design allows maintenance teams to maximize input density inside crowded marshaling cabinets without expanding panel footprints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGuarantees Multi-Signal Field Adaptability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe flexible hardware interface conditions both current loops (4-20 mA) and voltage inputs (0-10 VDC) natively. This multi-signal processing profile eliminates the need to buy standalone conversion barriers for varying transmitter types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResists Thermal Stress In Sealed Racks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe low-power internal hardware drawing standard 24 VDC produces minimal thermal dissipation. This optimized dissipation scheme prevents localized hot spots, extending the lifecycle of adjacent logic cards inside unventilated control enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 51199588-100 accept 4-20 mA and 0-10 V signals concurrently?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The independent analog channels allow you to route mixed signal types into the card file. Ensure you configure each targeted terminal junction according to the specific voltage or current loop wiring diagram provided in your system hardware manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat insertion steps protect the card backplane pins during replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePower down the target rack section if required by your specific system operating rules. Align the module card edges smoothly with the plastic guide rails of the file slot, push the module back until the pin headers match the backplane sockets completely, and lock the mechanical retaining screws to seal out vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this input module provide internal loop power for 2-wire transmitters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module primarily scans incoming analog signals. When interfacing with 2-wire field transmitters, you must route an external 24 VDC loop power supply through the signal path or verify that your specific backplane configuration supplies active terminal wetting voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43788550799459,"sku":"51199588-100","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/403_f64a39a1-4e62-4352-9203-5b4a34b6fad2.jpg?v=1761009466","url":"https:\/\/www.autocontrolglobal.com\/products\/51199588-100-honeywell-analog-input-module-tdc-3000","provider":"AutoControl Global","version":"1.0","type":"link"}