  • Manufacturer: HONEYWELL

  • Part Number: 51202938-010

  • Condition:New with Original Package

  • Product Type: Analog Input Modules

  • Country of Origin: Sweden

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Honeywell 51202938-010 FTA Interconnection Cable

The Honeywell 51202938-010 serves as the primary 51202938 FTA Interconnection Cable utilized to execute high-level analog input acquisition across Honeywell TDC 3000 / TPS / Experion PKS platforms. The physical assembly routes 4-20 mA DC or 1-5 VDC analog loops between Field Termination Assemblies (FTAs) and processing chassis components to maintain deterministic process variables.

Hardware Specifications

Parameter Specification
Model 51202938-010
Brand Honeywell
Origin USA
Weight 0.25 kg
Dimensions 2.9 x 31.8 x 27.8 cm
Operating Temp -20 deg C to +70 deg C
Storage Temp -40 deg C to +85 deg C
Power Supply 24 VDC via system backplane
Input Signal Range 4-20 mA DC or 1-5 VDC
Number of Channels 8 or 16 (configuration dependent)
Accuracy +/-0.1% of span (typical)
Isolation Channel-to-channel and system galvanic isolation
Humidity 5% - 95% non-condensing
Certifications CE, UL, CSA

Process Control & Network Integration Profiles

The hardware line supports continuous deployment of the 4-20 mA HART loop protocol by passing both secondary digital telemetry and primary analog signals without impedance distortion. System layouts leverage the integrated channel-to-channel isolation and galvanic protection profiles to suppress common-mode electrical transients across extended distances. This structural design mitigates thermal shifts and minimizes resistance deviations, preventing baseline calibration degradation in cold junction compensation (CJC) circuits operating on adjacent low-level termination paths.

Frequently Asked Questions

Q: What specific analog voltage and current ranges can this interconnect assembly accommodate?

A: The configuration processes standard industrial high-level analog signals rated at either 4-20 mA DC loop currents or 1-5 VDC potential differences.

Q: How does the cable interface handle high-voltage spikes originating from field devices?

A: The associated termination architecture incorporates channel-to-channel and system galvanic isolation properties that clamp electrical noise and isolate destructive voltage transients before they reach the main controller backplane.

Field Installation Guidelines

Route the connection assembly through designated industrial wire trays, ensuring the layout does not exceed the minimum physical bend radius specified for heavy-duty multi-conductor instrumentation cables. Align the standard interface connectors with the corresponding pins on the Field Termination Assembly and control modules, applying steady mechanical force until the integrated retention clips lock completely into place.

Maintain physical isolation inside the wire management system between these low-voltage analog paths and high-current AC power cables to prevent inductive cross-talk. Verify that the ambient operating environment remains within the standard limits of -20 deg C to +70 deg C before conducting full loop checks on the associated 24 VDC backplane supply lines.

You may also like