{"product_id":"51305072-300-honeywell-clcn-b-redundant-lcn-paddle-board","title":"51305072-300 Honeywell CLCN-B Redundant LCN Paddle Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 51305072-300 (Model Reference: CLCN-B) functions as a specialized Communication Link Control Network (CLCN) Paddle Board engineered for Honeywell TDC 3000 and Experion PKS distributed control systems (DCS). This interface card establishes the vital physical network connections required for the local control network (LCN) coaxial data bus, managing high-speed digital communications between system controllers, history modules, and universal stations. System architects deploy this B-side component to handle redundant network paths, ensuring that structural data monitoring continues without interruption when industrial facilities undergo primary line maintenance or sudden cable failures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51305072-300\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware Designation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCLCN-B (Redundant B-Side)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eComponent Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Link Control Network Paddle Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell TDC 3000 \/ Experion PKS Network Infrastructure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Utility Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExecutes Redundant LCN Data Routing (Channel B Path)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Mechanical Matching\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInstalls into standard 5-slot or 10-slot control chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundant Partner Board\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrates with CLCN-A (51305072-200) for dual redundancy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Formats Managed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed serialized real-time network digital signals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Outer Dimension\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Honeywell Paddle Board footprint (approx 307 mm length)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Assembly Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 kg (2.20 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +60 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Thermal Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGlobal Quality Certifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE marked, UL listed, CSA approved, TUV safety validated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEngineering Country of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcurement Status\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New and Original in Factory Packing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch3\u003eDual-Channel Coaxial Redundancy Prevents Network Communication Dropouts\u003c\/h3\u003e\n\u003cp\u003eThe 51305072-300 works alongside its partner module, the CLCN-A (51305072-200), to create a true dual-redundant local network architecture. While the A-side board manages standard daily traffic, the CLCN-B stands ready to assume the complete system communication load instantly. If physical plant hazards slice the primary network cable or a terminal connector breaks down, the underlying network hardware transfers data packets over the B-side channel in real time. This zero-microsecond switchover allows manufacturing lines, safety interlocks, and control consoles to maintain synchronized operations without dropping live process trends.\u003c\/p\u003e\n\u003ch3\u003eRigid Steel Backing Layout Isolates Vibrations in High-Stress Racks\u003c\/h3\u003e\n\u003cp\u003eIndustrial environments often transmit continuous mechanical resonances through steel control enclosures. The CLCN-B incorporates a heavy-duty mechanical frame layout that dampens high-frequency ambient vibration and low-frequency structure-borne shock. This physical stabilization safeguards the high-pin-count backplane gold connectors from microscopic rubbing and fretting corrosion, ensuring stable connection contact inside standard 5-slot and 10-slot DCS rack assemblies over years of uninterrupted deployment.\u003c\/p\u003e\n\u003ch3\u003eHardened B-Side Transceivers Reschedule Signals Around Field EMI\u003c\/h3\u003e\n\u003cp\u003eIndustrial network lines often parallel high-voltage machine power lines, causing heavy electromagnetic interference (EMI). The 51305072-300 integrates high-attenuation signal isolation transformers and dedicated transceiver shielding. This architecture filters out high-frequency electrical spikes and transient common-mode voltage ripples before they corrupt the internal digital network registers, ensuring stable error-free data packet flow between processing nodes in extreme ambient electrical environments.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat exact installation task must an engineer perform when pairing the CLCN-B with the CLCN-A?\u003c\/p\u003e\n\u003cp\u003eTo ensure correct dual-redundant operation, you must install the CLCN-B (51305072-300) into its designated redundant slot immediately adjacent to the matching CLCN-A (51305072-200) card inside the chassis. Connect the distinct B-side network trunk coax cable directly to the rear connector assembly of this board, leaving the A-side cable isolated on the primary module to preserve true physical network separation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the 51305072-300 board operate as a standalone communication interface if the CLCN-A card is missing?\u003c\/p\u003e\n\u003cp\u003eThe board contains the complete transceiver hardware necessary to read and write LCN network traffic independently. However, the Honeywell TDC 3000 and Experion network diagnostics will report a critical system redundancy fault flag if the A-side module is missing. To maintain full factory-warranted, fault-tolerant network operations in your plant, you must deploy the CLCN-B module strictly as part of a dual-redundant pair.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do the on-board status LEDs assist a technician during network diagnostic troubleshooting?\u003c\/p\u003e\n\u003cp\u003eThe front plate of the 51305072-300 houses explicit LED indicators that display real-time network link status, packet transmission activity, and hardware pass\/fail conditions. If the board detects transmission errors or a disconnected coax termination pin, the LEDs alter their pattern instantly, allowing maintenance crews to isolate a damaged field cable run without shutting down the main node software suite.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43850082943075,"sku":"51305072-300 (CLCN-B)","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/266_77b140eb-0d81-4c2e-be1f-707af4ca5729.jpg?v=1763946023","url":"https:\/\/www.autocontrolglobal.com\/products\/51305072-300-honeywell-clcn-b-redundant-lcn-paddle-board","provider":"AutoControl Global","version":"1.0","type":"link"}