{"product_id":"51306528-175-cc-tpox01-honeywell-c300-profibus-interface","title":"51306528-175 CC-TPOX01 | Honeywell | C300 PROFIBUS Interface","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TPOX01 (51306528-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Input Output Termination Assembly (IOTA) designed specifically for PROFIBUS DP communication within the Honeywell Experion PKS architecture. This baseplate serves as the physical and electrical interface for the C300 Series PROFIBUS Gateway, enabling the seamless integration of PROFIBUS DP field devices into the Honeywell control network. By utilizing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TPOX01 (51306528-175)\u003c\/strong\u003e, engineers can ensure deterministic data exchange between third-party motor control centers (MCCs), variable frequency drives (VFDs), and remote I\/O stations with the central C300 controller.\u003c\/p\u003e\n\u003cp\u003eEngineered for the demands of continuous industrial processing, this IOTA supports redundant configurations to prevent network downtime. It features a compact footprint optimized for high-density cabinet installations. We supply this component as 100% brand new and factory-original, ensuring your automation infrastructure maintains its validated status and operational reliability.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell (USA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TPOX01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51306528-175\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e: PROFIBUS DP (Decentralized Periphery)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Compatibility\u003c\/strong\u003e: Honeywell C300 \/ Experion PKS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Transmission Rate\u003c\/strong\u003e: Up to 12 Mbps (protocol limited)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e: Standard Honeywell C300 Carrier \/ Rack Installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e: 24 VDC nominal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -20 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e: 5% to 95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Diagnostics\u003c\/strong\u003e: Integrated LED indicators for link activity and fault detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 2.2 cm x 12.4 cm x 12.6 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.2kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Integration\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TPOX01 (51306528-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that PROFIBUS cycle times remain consistent, allowing for precise control of high-speed drives and critical field instruments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Ready\u003c\/strong\u003e: The baseplate design facilitates the connection of primary and secondary gateway modules, providing a robust failover mechanism for high-availability production lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Maintenance\u003c\/strong\u003e: The modular nature of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TPOX01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for quick hardware inspection. Compression terminals provide secure, vibration-resistant connections for field wiring, reducing the risk of intermittent communication faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this IOTA support both PROFIBUS DP and PA?\u003c\/strong\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TPOX01 (51306528-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for PROFIBUS DP. For PROFIBUS PA (Process Automation) applications, a dedicated link or coupler is typically required downstream of the DP network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 51306528-175 part number conformally coated?\u003c\/strong\u003eStandard Honeywell 175-suffix parts usually feature conformal coating for protection against moisture and corrosive atmospheric gases (G3 environment). Please verify specific project codes for confirmation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this with legacy TDC 3000 systems?\u003c\/strong\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TPOX01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically designed for the C300\/Experion PKS platform. Integration with legacy TDC systems requires an Experion PKS interface or a compatible bridge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44079175303267,"sku":"CC-TP0X01","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/367._e7d1624b-2642-4941-b174-d5738664dd87.jpg?v=1774487223","url":"https:\/\/www.autocontrolglobal.com\/products\/51306528-175-cc-tpox01-honeywell-c300-profibus-interface","provider":"AutoControl Global","version":"1.0","type":"link"}