{"product_id":"51308386-175-cc-tdil01-honeywell-c300-16-channel-di","title":"51308386-175 CC-TDIL01 | Honeywell | C300 16-Channel DI","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TDIL01 (51308386-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Digital Input (DI) module specifically engineered for the Honeywell Experion PKS C300 controller platform. This module serves as the primary interface for capturing discrete ON\/OFF signals from field devices, including limit switches, motor status auxiliary contacts, and emergency push buttons. By converting these field-side electrical signals into deterministic digital data, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TDIL01 (51308386-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables the controller to perform real-time interlocking, sequence logic, and alarm management.\u003c\/p\u003e\n\u003cp\u003eFeaturing 16 isolated channels, the module is built to prevent ground loops and electromagnetic interference (EMI) from disrupting system-level logic. The -175 suffix ensures the unit is equipped with a high-grade conformal coating, providing essential protection against moisture and corrosive atmospheric contaminants (G3 environment). We offer this unit as 100% Brand New and original equipment, ensuring full compliance with your plant's validated control system requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell (USA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TDIL01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51308386-175\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Capacity\u003c\/strong\u003e: 16 Isolated Digital Input Channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal Logic\u003c\/strong\u003e: Dry contact or voltage sensing (24 VDC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e: 18 to 30 VDC (24 VDC Nominal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e: Channel-to-channel and channel-to-system galvanic isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScan Update Rate\u003c\/strong\u003e: 100 ms typical (dependent on IOTA and controller load)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators\u003c\/strong\u003e: Front-facing status LEDs for power, fault, and communication status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Sink\u003c\/strong\u003e: Typical 2.5 mA per channel at 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -20 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity Limits\u003c\/strong\u003e: 5% to 95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 127 mm x 35 mm x 147 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e:  0.65 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Insights \u0026amp; Application\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Integrity\u003c\/strong\u003e: In heavy industrial environments, electrical noise can cause false signal triggering. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TDIL01 (51308386-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes advanced filtering and optical isolation to ensure that only valid state changes are reported to the controller database.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance Efficiency\u003c\/strong\u003e: The module includes comprehensive self-diagnostics. Maintenance teams can monitor the health of the input board through the Experion Station, allowing for rapid identification of hardware faults versus field wiring issues.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Architecture\u003c\/strong\u003e: Designed for quick insertion into a C300 I\/O Termination Assembly (IOTA), it allows for easy hardware scaling and replacement without disturbing existing field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the CC-TDIL01 (51308386-175) detect open-wire faults?\u003c\/strong\u003eThe module performs board-level diagnostics; however, specific open-wire detection usually depends on the field device type and whether the IOTA is configured for supervised inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with older C200 systems?\u003c\/strong\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TDIL01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically designed for the C300 and Series C I\/O architecture. For C200 systems, a different Series A or Series B I\/O module would typically be required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 51308386-175 part number signify?\u003c\/strong\u003eThe base part number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51308386\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erefers to the Printed Wire Assembly (PWA), and the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-175\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffix confirms it is a conformally coated, G3-rated component for high-availability process zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44079357362275,"sku":"CC-TDIL01 51308386 -175","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/372._4289d44e-3112-4399-9a64-1901605df498.jpg?v=1774490121","url":"https:\/\/www.autocontrolglobal.com\/products\/51308386-175-cc-tdil01-honeywell-c300-16-channel-di","provider":"AutoControl Global","version":"1.0","type":"link"}