5466-1002 Woodward MicroNet-Plus Digital Speed Control Power Module
5466-1002 Woodward MicroNet-Plus Digital Speed Control Power Module
5466-1002 Woodward MicroNet-Plus Digital Speed Control Power Module
/ 3

5466-1002 Woodward MicroNet-Plus Digital Speed Control Power Module

  • Manufacturer: Woodward

  • Part Number: 5466-1002

  • Condition:New with Original Package

  • Product Type: Power Supply Modules

  • Country of Origin: GERMANY

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Woodward 5466-1002 MicroNet-Plus Power Supply

The Woodward 5466-1002, also cataloged as the 5466-1002 Power Supply / Digital Speed Control Module, operates as a dedicated hardware component for regulated power distribution and turbine logic processing within MicroNet-Plus Digital Control systems.

Hardware Specifications

Parameter Specification
Model 5466-1002
Brand Woodward
Origin USA
Weight 21.8 kg
Dimensions Standard MicroNet-Plus 2-slot footprint
Operating Temp 0 deg C to +55 deg C
Power Consumption Not specified (Dependent on load)
Input Voltage 220 VAC / 250 VAC nominal
Backplane Slots 2 slots
CPU Capability Simplex or redundant support

Actuator Loop Feedback and Thermal Dissipation

The 5466-1002 maintains precise actuator loop feedback response, ensuring that control signal deviations remain within defined parameters during transient engine load changes. The thermal heat sink dissipation profile is engineered to manage high-density power conversion within the enclosed chassis, relying on forced air circulation to prevent internal component degradation. When utilized as a digital speed control processor, the module employs high-resolution sampling to stabilize governor output, effectively suppressing harmonic distortion within the actuator command circuit to maintain optimal turbine rotor speed.

Frequently Asked Questions

Q: Does the 5466-1002 support hot-swap capabilities during active generator control?

A: Hot-swapping is restricted in many MicroNet-Plus configurations. Consult the system-specific I/O scan settings and power distribution documentation to determine if the backplane requires a cold-start initialization upon module replacement.

Q: How does the module handle redundant power source input?

A: The power supply integrates with the system backplane to provide load sharing across redundant rails. Ensure that primary and backup power sources are phased correctly to prevent circulating currents between redundant modules.

Field Installation Guidelines

  1. Backplane Interface: Insert the module into the two designated slots on the MicroNet-Plus chassis. Ensure the connector pins are correctly aligned to prevent damage to the backplane communication bus.
  2. Cooling Requirements: Given the module power density, verify that forced-air fans in the rack are operational. In high-ambient temperature environments, ensure the intake air temperature does not exceed 55 deg C to maintain rated performance.
  3. Shielding and Grounding: Connect the module chassis to the system common ground bus using a low-impedance conductor. Route AC input wiring away from sensitive analog signal cables to minimize electromagnetic coupling into the speed-sensing circuit.
  4. Configuration Check: Before applying line voltage, confirm the input voltage jumpers match the 220 VAC or 250 VAC supply. Incorrect voltage settings will trigger immediate power supply protection faults.